18 resultados para Calibration coefficients

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The heat-transfer coefficients around a workpiece immersed in an electrically heated heat treatment fluidised bed were studied. A suspension probe designed to simulate a workpiece of complex geometry was developed to measure local total and radiative heat-transfer coefficients at a high bed temperature. The probe consisted of an energy-storage region separated by insulation from the fluidised bed, except for the measuring surface, and a multi-thermocouple measurement system. Experiments in the fluidised bed were performed for a fluidising medium of 120-mesh alumina, a wide temperature range of 110–1050 °C and a fluidising number range of 1.18–4.24. It was found that the workpiece surface temperature has a more significant effect on heat transfer than the bed temperature. The total heat-transfer coefficient at the upper surface of the workpiece sharply decreased at the start of heating, and then steadily increased as heating progressed, while a sharp decrease became a rapid increase and then a slow increase for the radiative heat-transfer coefficient. A great difference in the heat-transfer coefficients around the workpiece was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a pressing need in Australia and other countries to develop systems for monitoring secular trends in childhood obesity and related behavioural and environmental determinants. Energy from foods and beverages consumed at school is an accessible indicator of children’s eating patterns and we have developed a school food checklist (SFC) to measure this. The SFC records the number of serves and source (home, canteen, vending machine) of 20 food and beverage categories. This study aims to assess the accuracy and to calibrate the SFC by comparing it to a weighed record (WR) and to evaluate inter-recorder reliability. Participants were 910 primary school children aged 5 to 12 years from a rural township in Victoria, Australia. WR were collected from a nonrandom sub-sample of 106 and a second sub-sample (n=46) had intake measured twice using the SFC to assess inter-recorder reliability. Mean energy values were 2992 kJ ± 924 and 3008 kJ ± 952 for the SFC and WR respectively and the correlation coefficient was strong (Pearson r = 0.77). The mean difference between the WR and SFC methods was 15 kJ (95% CI, -107 kJ to 138 kJ) and the limits of agreement (+2 standard deviations) were ± 1270 kJ. The SFC overestimated the energy/serve of breads and fruit drinks and under-estimated energy/serve from fat spreads, biscuits/crackers, muesli/fruit bars and fruit. Inter-recorder reliability was good (kappa 0.51). The SFC was designed to measure energy from food and beverages in schools. It has good accuracy and reliability and the revised version should further improve accuracy of the instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glow-Discharge Optical Emission Spectrometry (GD-OES) is a powerful technique for the rapid analysis of elements in a solid surface as a function of depth. DC-GD-OES allows depth profiling on electrically conductive surfaces only, and has proven to be difficult for the analysis of insulating layers, such as oxides. However, the technique of radio-frequency (RF) GD-OES has the advantage of being able to depth profile through multiple layers, both conducting and insulating. In this work, a LECO GDS- 850A spectrometer was calibrated for aluminium, oxygen, and other elements, with the RF source installed. A quantitative depth profile for a sample of tempered aluminium alloy 7475 is presented and compared with earlier work[1,2].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of convection suppression devices has been widely discussed in the literature as a means of reducing natural convection heat loss from enclosed spaces. In this study the use of a single baffle was examined as a possible low cost means of suppressing heat loss by natural convection in an attic shaped enclosure.

Recently the authors experimentally demonstrated that the natural convection heat transfer for an attic shaped enclosure with Grashof Numbers in the range of 107 to 109 [1] could be predicted using a correlation in the literature developed for Grashof Numbers in the range 105 and 106 [2]. However, in this study the impact of adding a single baffle to the enclosure was examined. It was found that the heat transfer coefficient changes with increasing baffle length, and can be predicted using a modified form of the correlation presented in [1], as shown in Eq. (1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the coordinated use of video and audio cues to capture and index surveillance events with multimodal labels. The focus of this paper is the development of a joint-sensor calibration technique that uses audio-visual observations to improve the calibration process. One significant feature of this approach is the ability to continuously check and update the calibration status of the sensor suite, making it resilient to independent drift in the individual sensors. We present scenarios in which this system is used to enhance surveillance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we investigate the use of a wavelet transform-based analysis of audio tracks accompanying videos for the problem of automatic program genre detection. We compare the classification performance based on wavelet-based audio features to that using conventional features derived from Fourier and time analysis for the task of discriminating TV programs such as news, commercials, music shows, concerts, motor racing games, and animated cartoons. Three different classifiers namely the Decision Trees, SVMs, and k-Nearest Neighbours are studied to analyse the reliability of the performance of our wavelet features based approach. Further, we investigate the issue of an appropriate duration of an audio clip to be analyzed for this automatic genre determination. Our experimental results show that features derived from the wavelet transform of the audio signal can very well separate the six video genres studied. It is also found that there is no significant difference in performance with varying audio clip durations across the classifiers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose

To test a field-based protocol using intermittent activities representative of children's physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity.
Methods

Twenty-eight children (46% boys) aged 10–11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 activities representative of children's play. A validated direct observation protocol was used as the criterion measure of physical activity. Receiver Operating Characteristics (ROC) curve analyses were conducted with four semi-structured activities to determine the accelerometer cut-points. To examine classification differences, cut-points were cross-validated with free-play and DVD viewing activities.
Results

Cut-points of ≤372, >2160 and >4806 counts•min−1 representing sedentary, moderate and vigorous intensity thresholds, respectively, provided the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of the activity). Cross-validation data demonstrated that these values yielded the best overall kappa scores (0.97; 0.71; 0.62), and a high classification agreement (98.6%; 89.0%; 87.2%), respectively. Specificity values of 96–97% showed that the developed cut-points accurately detected physical activity, and sensitivity values (89–99%) indicated that minutes of activity were seldom incorrectly classified as inactivity.
Conclusion

The development of an inexpensive and replicable field-based protocol to generate behaviourally valid and population-specific accelerometer cut-points may improve the classification of physical activity levels in children, which could enhance subsequent intervention and observational studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose : This study was conducted to devise a new individual calibration method to enhance MTI accelerometer estimation of free-living level walking speed.

Method : Five female and five male middle-aged adults walked 400 m at 3.5, 4.5, and 5.5 km·h-1, and 800 m at 6.5 km·h-1 on an outdoor track, following a continuous protocol. Lap speed was controlled by a global positioning system (GPS) monitor. MTI counts-to-speed calibration equations were derived for each trial, for each subject for four such trials with each of four MTI, for each subject for the average MTI, and for the pooled data. Standard errors of the estimate (SEE) with and without individual calibration were compared. To assess accuracy of prediction of free-living walking speed, subjects also completed a self-paced, "brisk" 3-km walk wearing one of the four MTI, and differences between actual and predicted walking speed with and without individual calibration were examined.

Results : Correlations between MTI counts and walking speed were 0.90 without individual calibration, 0.98 with individual calibration for the average MTI, and 0.99 with individual calibration for a specific MTI. The SEE (mean ± SD) was 0.58 ± 0.30 km·h-1 without individual calibration, 0.19 ± 0.09 km·h-1 with individual calibration for the average MTI monitor, and 0.16 ± 0.08 km·h-1 with individual calibration for a specific MTI monitor. The difference between actual and predicted walking speed on the "brisk" 3-km walk was 0.06 ± 0.25 km·h-1 using individual calibration and 0.28 ± 0.63 km·h-1 without individual calibration (for specific accelerometers).

Conclusion : MTI accuracy in predicting walking speed without individual calibration might be sufficient for population-based studies but not for intervention trials. This individual calibration method will substantially increase precision of walking speed predicted from MTI counts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Examine the predictive validity of the activPAL™ metabolic equivalents equation, develop an activPAL™ threshold value to define moderate-to vigorous-intensity physical activities, and examine the classification accuracy of the developed moderate-to vigorous-intensity physical activities threshold value in 4- to 6-year-old children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In neuroscience, the extracellular actions potentials of neurons are the most important signals, which are called spikes. However, a single extracellular electrode can capture spikes from more than one neuron. Spike sorting is an important task to diagnose various neural activities. The more we can understand neurons the more we can cure more neural diseases. The process of sorting these spikes is typically made in some steps which are detection, feature extraction and clustering. In this paper we propose to use the Mel-frequency cepstral coefficients (MFCC) to extract spike features associated with Hidden Markov model (HMM) in the clustering step. Our results show that using MFCC features can differentiate between spikes more clearly than the other feature extraction methods, and also using HMM as a clustering algorithm also yields a better sorting accuracy.