7 resultados para Ansys

em Deakin Research Online - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a novel optical fibre based micro contact probe system with high sensitivity and repeatability. In this optical fibre probe with a fused spherical tip, a fibre Bragg grating has been utilized as a strain sensor in the probe stem. When the probe tip contacts the surface of the part, a strain will be induced along the probe stem and will produce a Bragg wavelength shift. The contact signal can be issued once the wavelength shift signal is produced and demodulated. With the fibre grating sensor element integrated into the probe directly, the probe system shows a high sensitivity. In this work, the strain distributions along the probe stem with the probe under axial and lateral load are analysed. A simulation of the strain distribution was performed using the finite element package ANSYS 11. Performance tests using a piezoelectric transducer stage with a displacement resolution of 1.5 nm yielded a measurement resolution of 60 nm under axial loading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energy crisis is one of the major obstacles for human development. There are on-going researches to overcome this for a sustainable environment and economy. Passive air cooling system of earth pipe cooling is seen as a viable energy efficient technology for hot and humid subtropical climates. It can be an attractive economical alternative to conventional cooling since there are no compressors or any habitual mechanical unit. It utilizes earth’s near constant underground temperature to cool air for residential, agricultural or industrial uses. This paper reports the thermal performance of earth pipe cooling technology for a hot and humid subtropical climatic zone in Queensland, Australia. A series of pipes buried underground were used in order to increase the cooling performance of the system. To measure the thermal performance, a thermal model was developed for the earth pipe cooling system and simulated using ANSYS Fluent. Data were collected from two modelled rooms built from shipping containers and installed at Central Queensland University, Rockhampton, Australia. The impact of air temperature and velocity on room cooling performance has also been assessed. A significant temperature reduction is seen in this study, which will save energy cost for thermal cooling in buildings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Finite Element (FE) model updating has been attracting research attentions in structural engineering fields for over 20 years. Its immense importance to the design, construction and maintenance of civil and mechanical structures has been highly recognised. However, many sources of uncertainties may affect the updating results. These uncertainties may be caused by FE modelling errors, measurement noises, signal processing techniques, and so on. Therefore, research efforts on model updating have been focusing on tackling with uncertainties for a long time. Recently, a new type of evolutionary algorithms has been developed to address uncertainty problems, known as Estimation of Distribution Algorithms (EDAs). EDAs are evolutionary algorithms based on estimation and sampling from probabilistic models and able to overcome some of the drawbacks exhibited by traditional genetic algorithms (GAs). In this paper, a numerical steel simple beam is constructed in commercial software ANSYS. The various damage scenarios are simulated and EDAs are employed to identify damages via FE model updating process. The results show that the performances of EDAs for model updating are efficient and reliable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we present the concept of planar polymer photonic waveguides for the health monitoring of aerospace structures. Here a polymer layer is deposited onto the material/structure to be monitored. Within the polymer layer, waveguides are created after deposition. These waveguides can then be used as 'optical fibres' for optical fibre sensing methodologies. In investigating the use of polymer photonic waveguides the question to be answered is: does the strain in the test material transfer to the polymer layer, such that the value to be measured optically is reliable and indicative of the true strain in the test structure? To answer this question we have conducted a preliminary structural analysis with finite element analysis, utilising ANSYS. A simple aluminium cantilever was used as the test structure, and layers of polyethylene with different thicknesses were added to this. Result show that the thinner the layer of polymer, the more accurate the measured strain will be. For a 100um coating, the difference is strain was observed to be on the order of 3.3%. © 2014 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energy consumption in heating and cooling around the world has been a major contributor to global warming. Hence, many studies have been aimed at finding new techniques to save and control energy through energy efficient measures. Most of this energy is used in residential, agricultural and commercial buildings. It is therefore important to adopt energy efficiency measures in these buildings through new technologies and novel building designs. These new building designs can be developed by employing various passive cooling systems. Earth pipe cooling is one of these which can assist to save energy without using any customary mechanical units. This paper investigates the earth pipe cooling performance in a hot humid subtropical climate of Rockhampton, Australia. A thermal model is developed using ANSYS Fluent for measuring its performance. Impacts of air velocity, air temperature, relative humidity and soil temperature on room cooling performance are also assessed. A temperature reduction of around 2 °C was found for the system. This temperature reduction contributed to an energy saving of a maximum of 866.54 kW (8.82%) per year for a 27.23 m3 room.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energy crisis is one of the major problems facing the progress of human society. There are several energy-efficient technologies that can be applied to save energy and make a sustainable environment. Passive air cooling of earth pipe cooling technology is one of them to reduce the energy consumption for hot and humid subtropical climates. The technology works with a long buried pipe with one end for intake air and the other end for providing air cooled by soil to the desired space such as residential, agricultural, or industrial buildings. It can be an attractive economical alternative to conventional cooling since there are no compressors or any customary mechanical unit. This chapter reports the performance of a vertical earth pipe cooling system for a hot and humid subtropical climatic zone in Queensland, Australia. A series of buried pipes were installed in vertical arrangement in order to increase earth pipe cooling performance. To measure the performance of the system, a numerical model was developed and simulated using the CFD software Fluent in ANSYS 15.0. Data were collected from two modeled rooms built from two shipping containers and installed at the Sustainable Precinct at Central Queensland University, Rockhampton, Australia. The impact of air temperature and velocity on room cooling performance has also been assessed. A temperature reduction of 1.82 °C was observed in the room connected to the vertical earth pipe cooling system, which will save the energy cost for thermal cooling in buildings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energy efficiency of a building has become a major requirement since the building sector produces 40%-50% of the global greenhouse gas emissions. This can be achieved by improving building’s performance through energy savings, by adopting energy efficient technologies and reducing CO2 emissions. There exist several technologies with less or no environmental impact that can be used to reduce energy consumption of the buildings. Earth pipe cooling system is one of them, which works with a long buried pipe with one end for intake air and the other end for providing air cooled by soil to the building. It is an approach for cooling a room in a passive process without using any habitual mechanical unit. The paper investigates the thermal performance of a horizontal earth pipe cooling system in a hot and humid subtropical climatic zone in Queensland, Australia. An integrated numerical model for the horizontal earth pipe cooling system and the room (or building) was developed using ANSYS Fluent to measure the thermal performance of the system. The impact of air temperature, soil temperature, air velocity and relative humidity on room cooling performance has also been assessed. As the soil temperature was below the outdoor minimum temperature during the peak warming hours of the day, it worked as an effective heat sink to cool the room. Both experimental and numerical results showed a temperature reduction of 1.11oC in the room utilizing horizontal earth pipe cooling system which will assist to save the energy cost in the buildings.