141 resultados para rigid contact lenses


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose To document contact lens prescribing patterns in the United States between 2002 and 2014. Methods A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. Results Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. Conclusions This survey has revealed prescribing trends and preferences in the United States over the past 13 years.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research presents a novel haptic grasping interface and demonstrates its ability within multi-point event-based feedback. Through experimental methodology, the dynamics involved in grasp contact interactions are modelled based on first principles. The proposed approach demonstrates a method of realistically representing grasp contact with rigid virtual objects through multi-point interaction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new homologous series of norbornylogous (NB) bridges has been synthesized in which the average curvature of the bridges is very small. The molecules are rigid and have two thiol moieties at each end to allow them to form self-assembled monolayers (SAMs) and to connect to two gold electrodes to form a molecular junction. The SAMs formed were characterized using electrochemistry to determine the surface coverage of molecules on gold surface and to provide an indication of the packing of the NB bridges while ellipsometry and X-ray photoelectron spectroscopy (XPS) were used to provide an indication of the SAM thickness and orientation. Single molecule conductance of NB bridges was measured as a function of the molecular length. The conductance was found to decrease exponentially with the length with a decay constant that is exactly correlated with photoelectron transfer and other studies at the multiple molecule level. The molecule−electrode contact resistance was determined and compared with that of related alkanedithiol molecular junctions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. To investigate initial comfort and adaptation of currently successful low oxygen transmissibility soft lens wearers refitted with silicone hydrogel (SH) lenses for daily wear.

Methods. Fifty-five subjects were enrolled in a subject-masked 5-month clinical trial in which they wore 5 SH lenses in a randomized, crossover design. Comfort, burning, and dryness were rated on scales of 0 to 100 immediately on insertion and the time for lens settling was recorded. Symptoms were then rated at various times, using BlackBerry wireless communication devices (Research in Motion, Waterloo, Canada), during the day for 2 cycles of 2 weeks wear for each lens type.

Results. Comfort immediately on insertion varied between lens types (P=0.002). All lens types were reported by the subjects to have settled within 30 to 45 sec of insertion (P=0.14) and settled comfort was greater than comfort immediately on insertion (P<0.001). Comfort within the first hour of wear also varied between lens types (P=0.02). Comfort during the day decreased significantly for all lenses (P=0.001), but there was no difference between lenses (P=0.19) and no effect of lens age (P=0.15). The wearing times were greater with the SH lenses than the habitual lenses worn before study commencement (P=0.001). Overall performance of the lenses after 4 weeks was high, with no difference between lenses (P=0.45).

Conclusions. Initial comfort and adaptation to all SH lenses were good and no differences in the overall ratings were found between the 5 SH lenses investigated. Decreased comfort was noted later in the day with all lens types, but longer wearing times were reported with the SH lenses than previous hydroxyethyl methacrylate-based lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To assess eye care practitioners (ECPs) recommendations for replacement frequency (RF) of silicone hydrogel (SH) and daily disposable (DD) lenses in Canada and the U.S. and to compare noncompliance (NC) with manufacturer recommended RF by the ECP and patient, and the reasons given for NC.

Methods. Invitations to participate were sent by e-mail to ECPs in Canada and the U.S. Twenty patient surveys were sent to 420 ECPs, and 2232 eligible surveys were received from 216 ECPs (26% Canada, 74% U.S.). Questions related to patient demographics, lens type, wearing patterns, ECP instructions for RF, and actual patient RF. ECPs provided lens information and their recommendation for RF after the surveys were completed and sealed in envelopes. Responses were anonymous.

Results. DD accounted for 18% (Canada) vs. 16% (U.S.) of wearers (p > 0.05); 35% (Canada) vs. 45% (U.S.) wore 2-week replacement SH (2WR; p = 0.011); and 47% (Canada) vs. 39% (U.S.) wore 1-month replacement SH (1MR) lenses (p = 0.025). Thirty-four percent (Canada) vs. 18% (U.S.) of ECPs recommended longer RFs than the manufacturer recommended RF for 2WR lens wearers (p < 0.001); 6% (Canada) vs. 4% (U.S.) for DD wearers; and 2% (Canada) vs. 1% (U.S.) for 1MR lens wearers. NC rates for actual RFs reported by patients were not different between countries (p > 0.05) and were lowest for DD (13% Canada, 12% U.S.), followed by 1MR (33% Canada, 28% U.S.). The highest NC rates were with 2WR (50% Canada, 52% U.S.). The most frequent reason for NC with 2WR and 1MR was “forgetting which day to replace lenses” (54% Canada, 53% U.S.) and in DD wearers “to save money” (56% Canada, 29% U.S., p < 0.001).

Conclusions. 1MR lenses are more frequently prescribed in Canada. ECPs in Canada were NC with 2WR lenses more frequently than U.S. ECPs, but patient NC rates were the same in both countries for all lens types. ECP and patient NC rates were highest for 2WR lens wearers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. The Menifocal Z is an alternating vision, concentric, bifocal gas-permeable (GP) contact lens; center distance is connected to near periphery by a smooth transition zone. The lens is produced using tisilfocon A (Menicon Z material), which is approved for up to 30 days of continuous wear (CW). The aim of this study was to evaluate the clinical performance of the Menifocal Z when worn for up to 30 days of CW for 6 months.

Methods. Thirty-five existing GP lens wearers were enrolled in the study. Subjects were fitted with Menifocal Z lenses and follow-up visits were conducted after 2 weeks of daily wear and 1 day, 1 week, 6 weeks, 3 and 6 months of CW. A range of objective and subjective clinical performance measures were assessed, including distance and near visual acuity, the physiological response to CW, and subjective evaluation of vision and comfort.

Results. Twenty-seven subjects (77%) completed the study and eight (23%) discontinued: five (14%) as a result of lens-related problems (four vision, one comfort) and three (9%) as a result of non-lens related reasons. Average CW time achieved by the subjects was 22 ± 2 days. Mean binocular logarithm of the minimum angle of resolution (logMAR) acuities at 6 months were: high contrast distance 0.03 (20/20-), low contrast distance 0.63 (20/80-), and high contrast near 0.26 (20/25, N4). Adverse responses and lens binding were minimal, and there were no significant increases in corneal staining, corneal vascularization, or superior palpebral conjunctival papillae over time (p > 0.05). Problems with night vision (distance and near) with the lenses were the most common difficulties reported by the subjects.

Conclusions. The Menifocal Z appears to be a promising option for presbyopic vision correction, providing successful correction of distance and near vision in a group of experienced GP lens wearers. The hyper Dk tisilfocon A (Menicon Z) material allowed for safe wear of the lenses on a CW basis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recent launch of the Air Optix Aqua Multifocal lens (Ciba Vision) means that there are three silicone hydrogel (SiHy) multifocal lenses available. The benefits of SiHy materials have been well documented (Dumbleton, 2006), but until recently they weren't available in multifocal designs. With an aging population, it's likely that a large number of contact lens wearers are approaching presbyopia, which will result in a dramatic increase in demand for multifocal lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is the eighth consecutive year that we have presented data from a survey of international contact lens prescribing in Contact Lens Spectrum. In this article we report on an assessment of 25,801 fits across 28 contact lens markets located in North America, Europe, the Middle East, Asia, and Africa. As in previous years, we opted for a prospective approach to this work. Up to 1,000 survey forms were randomly disseminated in each market to contact lens practitioners (ophthalmologists, optometrists, and/or opticians depending on the market), and information about the first 10 patients prescribed with lenses after receipt of paper or electronic survey forms was anonymously recorded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Along with other facets of commericialization, the contact lens market has become globalized during the past 30 years. The major international companies have worldwide distribution networks and supply lenses of the same product names and replacement frequencies to all nations, with a few minor adjustments for marketing and regulatory reasons. Small and medium-sized companies, often producing more specialized lenses, are also active in markets across the world.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador: