111 resultados para protective coatings


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic coatings have been used in conjunction with cathodic protection as the most economical method of corrosion protection by the oil and gas pipeline industry. In a bid to prolong the life of the pipelines, the degradation and failure of pipeline coatings under the effects of major influencing factors including mechanical stress, the environmental corrosivity and cathodic protection have been extensively investigated over the past decades. This paper provides an overview of recent research for understanding coating degradation under the effect of these factors, either individually or in combination. Electrochemical impedance spectroscopy remains the primary and the most commonly used technique of studying the degradation of organic coatings, although there have been attempts to use other techniques such as electrochemical polarization (both dynamic and static), electrochemical noise, Scanning Kelvin Probe, Fourier Transform Infrared Spectroscopy, Differential Scanning Calorimetry and Dynamic Mechanical Analyser. Major knowledge and technological gaps in the investigation of the combined effects of mechanical stress, environmental corrosivity and cathodic protection on coating degradation have been identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mitigation of external corrosion of energy pipelines by a combination of barrier coatings and Cathodic Protection (CP) is not always effective. Even when design specifications are properly met, the shielding of cathodic protection current from reaching steel surface by disbonded barrier coatings, often referred to as cathodic shielding, may lead to severe corrosion problems such as deep pitting, high and near neutral pH Stress Corrosion Cracking (SCC) and Microbiologically Induced Corrosion (MIC). Unfortunately, current indirect assessment methods used in the pipeline industry have serious difficulties in detecting such corrosion problems. This paper provides a brief review of current techniques and their limitations when being applied under complex buried pipeline environmental conditions. The main purpose is to identify potential methods that could be utilised in the design of new monitoring probes specific for the monitoring of cathodic shielding and corrosion of disbonded coatings in the pipeline industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates risk and protective factors for substance abuse in a sample of 1778 students attending technical colleges in Bangkok and Nakhon Ratchasima provinces of Thailand using a self-report questionnaire modified from the Communities That Care youth survey. Low school commitment was strongly associated with illicit drug use, with adjusted odds ratios ranging from 2.84 (glue sniffing) to 10.06 (ecstasy). Having friends using drugs, and friends with delinquent behaviors increased the risk of using alcohol and illegal drugs, with adjusted odds ratios of 6.84 and 6.72 respectively for marijuana use. For protective factors, approximately 40-60% of students with high levels of moral belief, participation in religious activities, and social skills were less likely to use alcohol. It is concluded that peer influence is a significant contributor to Thai adolescents' participation in substance abuse and that engaging in religiosity may assist adolescents to internalize negative aspects of harmful drugs into positive perceptions and encourage them to avoid alcohol and illegal drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 Evolved over millions of years’ natural selection, very thin and lightweight wild silkworm cocoons can protect silkworms from environmental hazards and physical attacks from predators while supporting their metabolic activity. The knowledge of structure-property-function relationship of multi-layered composite silk cocoon shells gives insight into the design of next-generation protection materials. The mechanical and thermal insulation properties of both domestic (Bombyx mori, or B. moriand Samia. cynthia, or S. cynthia) and wild (Antheraea pernyi and Antheraea mylitta, or A. pernyi and A. mylitta) silkworm cocoons were investigated. The research findings are of relevance to the bio-inspired design of new protective materials and structures.
The 180 degree peel tests and needle penetration tests were used for examining the peel resistance and needle penetration resistance of both domestic and wild silkworm cocoon walls. The temperatures inside and outside of the whole silkworm cocoons under warm, cold and windy conditions were monitored for investigating the cocoon’s thermal insulation function. Computational fluid dynamics (CFD) models were created to simulate the heat transfer through the A. pernyi cocoon wall.
The wild cocoons experienced much higher peeling peak loads than the domestic cocoon. This transfers to a maximum work-of-fracture (WOF) of about 1000 J/m2 from the A. pernyi outer layer, which was 10 times of the B. mori cocoon. The A. pernyi wild cocoon exhibited a maximum penetration force (11 N) that is 70 % higher than a woven aramid fabric. Silk sericin is shown to play a critical role in providing needle penetration resistance of the non-woven composite cocoon structure by restricting the relative motion of fibres, which prevents the sharp tip of the needle from pushing aside fibres and penetrating between them. The wild A. pernyi cocoon exhibits superior thermal buffer over the domestic B. mori cocoon. The unique structure of the A. pernyi cocoon wall with mineral crystals deposited on the cocoon outer surface, can prohibit most of the air from flowing inside of the cocoon structure, which shows strong wind resistance under windy conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fe3Al–Al2O3 double-layer coatings (DC), Fe3Al-Fe3Al/50%Al2O3–Al2O3 triple-layer coatings (TC) and Fe3Al-Al2O3 graded coatings (GC) were produced from a series of Fe3Al/Al2O3 composite powders with different compositions on low carbon steel substrate using PLAXAIR plasma spraying equipment. Friction behaviors and wear resistance of the three kinds of coatings have been investigated under different loads. Tests were carried out using an MRH-3 standard machine, in lineal contact sliding under dry condition against hardmetal, at a sliding velocity of about 1.57 ms−1. Wear rates under different loads were measured and the friction coefficients were recorded. SEM analysis was carried out to identify the wear mechanisms. The results show that the GC has higher wear-resistance than DC and TC. The tribological characteristics of graded coating were different along the depth of the coatings, and the surface of coatings with pure Al2O3 does not show the best wear resistance. The wear rate and friction coefficients were also different under different loads. The failure types of plasma-sprayed Fe3Al-Al2O3 graded coatings in lineal contact were: loosening of ceramic particles, crack nucleation and propagation, brittle fracture, plastic deformation, and adhesive wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Underground pipeline corrosion monitoring is a complex technical challenge. Currently there is no corrosion monitoring probe that is able to provide in situ information on corrosion under disbonded coatings. This paper presents a proof of concept of a novel corrosion monitoring probe intended to simulate corrosion under disbonded pipeline coatings and monitor its rate under Cathodic Protection (CP). The probe's capabilities to measure corrosion rates and simulate disbonded coating conditions are illustrated by a typical experiment that involved testing of the probe in 0.1M NaCl at -850mVCSE. Estimated metal thickness losses based on results measured by the probe were compared against corrosion patterns and profilometry measurements of control specimens exposed to the same conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comorbidity between problem gambling and internalising disorders (anxiety and depression) has long been recognised. However, it is not clear how these relationships develop, and what factors can foster resilience to both conditions. The current study draws on longitudinal cohort data to investigate: 1) the cross-sectional and longitudinal relationships between problem gambling and internalising symptoms; 2) whether there are common and/or specific social environmental factors protective against both internalising symptoms and problem gambling in young adulthood; and 3) interactive protective factors (i.e., those that moderate the relationship between problem gambling and internalising symptoms).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a novel corrosion monitoring probe designed for simulating the conditions developed under disbonded coatings and for measuring current densities and their distribution over a simulated pipeline surface. The probe’s concept was experimentally evaluated via immersion tests under Cathodic Protection (CP) in high resistivity aqueous solution. Under the disbonded area, anodic currents as well as cathodic currents were both measured. Anodic current densities were used to calculate metal losses by means of Faraday’s law. Calculated corrosion patterns were compared with corrosion damage observed at the probe’s surface after a period of test. The probe’s working principles are explained in terms of simple electrochemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to assess a number of coatings developed for Mg for biomedical applications. The Mg substrates were high-purity (HP) Mg and ME10, an alloy recently developed for improved extrudability. The research utilized the new fishing-line specimen configuration to allow direct comparison to our recent in vivo and in vitro measurements. The in vitro measurements were immersion tests of fishing-line specimens immersed in Nor's solution at 37 °C. Tests of substantial duration are needed because the corrosion rates of uncoated samples are low. Nor's solution is the designation given to Hank's solution through which CO2 is bubbled at a partial pressure of 0.009 atm. In this solution, pH is maintained constant by the interaction of CO2 and the bicarbonate ions in the solution. This is the same buffer as that which maintains the pH of blood. Coatings examined were: (i) an anodization using a bio-friendly alkaline electrolyte consisting of phosphate, borate, and metasilicate, (ii) octyltrimethoxysilane (OSi), (iii) 1,2-bis[triethoxysilyl]ethane (BTSE), (iv) anodization+OSi, and (v) anodization + BTSE. The performance of coated samples was comparable to or better than that of the uncoated samples, and there was a substantially better performance for the ME10 samples after anodization+OSi. Reasons for the various performances are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of superhydrophobic surfaces with mechanical durability is challenging because the surface microstructure is easily damaged. Herein, we report superhydrophobic conductive graphite nanoplatelet (GNP)/vapor-grown carbon fiber (VGCF)/polypropylene (PP) composite coatings with mechanical durability by a hot-pressing method. The as-prepared GNP/VGCF/PP composite coatings showed water contact angle (WCA) above 150° and sliding angle (SA) less than 5°. The superhydrophobicity was improved with the increase of VGCF content in the hybrid GNP and VGCF fillers. The more VGCFs added in the GNP/VGCF/PP composite coating, the higher porosity on the surface was formed. Compared to the GNP/PP and VGCF/PP composite coatings, the GNP and VGCF hybrid fillers exhibited more remarkable synergistic effect on the electrical conductivity of the GNP/VGCF/PP composite coatings. The GNP/VGCF/PP composite coating with GNP:VGCF = 2:1 possessed a sheet resistance of 1 Ω/sq. After abrasion test, the rough microstructure of the GNP/VGCF/PP (2:1) composite coating was mostly restored and the composite coating retained superhydrophobicity, but not for the VGCF/PP composite coating. When the superhydrophobic surface is mechanically damaged with a loss of superhydrophobicity, it can be easily repaired by a simple way with adhesive tapes. Moreover, the oil-fouled composite surface can regenerate superhydrophobicity by wetting the surface with alcohol and subsequently burning off alcohol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method for measuring localized corrosion under disbonded coatings by means of an electrochemical sensor, denoted differential aeration sensor (DAS). It measures the distribution of electrochemical currents over an electrode array surface partially covered by a crevice that simulates a disbonded coating. The DAS has been evaluated using immersion tests at open circuit and under cathodic protection (CP) conditions. Under both conditions, anodic as well as cathodic current densities were detected within the crevice. A fundamental understanding for the detection of anodic currents under CP has been explained in terms of basic electrochemistry. Based on the current distribution data provided by the sensor, two different analysis methods have been used to estimate corrosion and its distribution. These methods consisted of a direct application of Faraday's Law to the anodic currents detected by the array, and on a sensor-specific method denoted corrected currents' method. It has been demonstrated that under diffusion controlled conditions this latter method produces a better corrosion estimation than the direct application of Faraday's Law. The corrected currents' method allowed the estimation of corrosion patterns outside the crevice under CP. Good correlation between electrochemical calculations and surface profilometry results has been obtained.