94 resultados para force majeure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adoption of Building Information Modelling (BIM) is one of the greatest technological innovations in the construction industry to date. However, the implementation of BIM lags far behind its potential due to the existence of various barriers. Strong government support is critical for the successful development and deployment of complex technology systems. BIM could seek government support to drive its implementation process and overcome the barriers. Through a survey, this paper aims to discover stakeholders’ expectations of the government role in BIM implementation and explores specific ways for governments to promote BIM implementation. The research findings are expected to assist related departments to accelerate BIM implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses design and fabrication processes in the development of a wearable and flexible conductive resistive sensor. The design and development of the sensor involve the use of Sn-Ag-Cu (SAC)plated Nylon fabric, precisionfused deposition modeling(FDM) using silicone and petrolatum for etch-resistant masks using the EnvisionTEC GmbH Bioplotter, and wet etching using Chromium, Ammonium Persulphate, and Salt-Vinegar etching solutions. Preliminary testing with other mask types, development processes, and sensor design approaches for various applications are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technologies, such as Atomic Force Microscopy (AFM), have proven to be one of the most versatile research equipments in the field of nanotechnology by providing physical access to the materials at nanoscale. Working principles of AFM involve physical interaction with the sample at nanometre scale to estimate the topography of the sample surface. Size of the cantilever tip, within the range of few nanometres diameter, and inherent elasticity of the cantilever allow it to bend in response to the changes in the sample surface leading to accurate estimation of the sample topography. Despite the capabilities of the AFM, there is a lack of intuitive user interfaces that could allow interaction with the materials at nanoscale, analogous to the way we are accustomed to at macro level. To bridge this gap of intuitive interface design and development, a haptics interface is designed in conjunction with Bruker Nanos AFM. Interaction with the materials at nanoscale is characterised by estimating the forces experienced by the cantilever tip employing geometric deformation principles. Estimated forces are reflected to the user, in a controlled manner, through haptics interface. Established mathematical framework for force estimation can be adopted for AFM operations in air as well as in liquid mediums.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study investigated the effects of circadian rhythm of cortisol (C) and testosterone (T) on maximal force production (Fpeak) and power output (Ppeak). Twenty male university students (mean age = 23.8 ± 3.6 years, height = 177.5 ± 6.4 cm, weight = 78.9 ± 11.2 kg) performed 4 time-of-day testing sessions consisting of countermovement jumps (CMJs), squat jumps (SJ), isometric midthigh pulls (IMTPs), and a 1-repetition maximum (1RM) squat. Saliva samples were collected at 0800, 1200, 1600, and 2000 hours to assess T and C levels on each testing day. Session rate-of-perceived exertion (RPE) scores were collected after each session. The results showed that Fpeak and Ppeak presented a clear circadian rhythm in CMJ and IMTP but not in SJ. One repetition maximum squat did not display a clear circadian rhythm. Session RPE scores collected at 0800 and 2000 hours were significantly (p ≤ 0.05) higher than those obtained at 1200 and 1600 hours. Salivary T and C displayed a clear circadian rhythm with highest values at 0800 hours and lowest at 2000 hours; however, no significant correlation was found between T and C with Fpeak and Ppeak. A very strong correlation was found between Taural with Fpeak of CMJ and IMTP and Ppeak of CMJ (r = 0.86, r = 0.84 and r = 0.8, p ≤ 0.001). The study showed the existence of a circadian rhythm in Fpeak and Ppeak in CMJ and IMTP. The evidence suggests that strength and power training or testing should be scheduled later during the day. The use of Taural seemed to be a more effective indicator of physical performance than hormonal measures, and the use of session RPE should also be closely monitored because it may present a circadian rhythm.