114 resultados para continuous carbonization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple continuous flow wet-spinning method to achieve mechanical reinforcement of the two oppositely charged biopolymers chitosan and gellan gum is described. The mechanical properties of these biopolymers are influenced by the order of addition. Using a facile method for mechanical reinforcement of gellan gum/chitosan fibers resulted in increases in Young's modulus, tensile strength, and toughness. Spinning gellan gum into chitosan resulted in the strongest fibers. We show that our fibers can provide a mechanical alternative for bio-fibers without the need of cross-linking. It is demonstrated that the fibers become ionically conducting in the presence of water vapor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotavirus replication occurs in vivo in intestinal epithelial cells. Cell lines fully permissive to rotavirus include kidney epithelial (MA104), colonic (Caco-2) and hepatic (HepG2) types. Previously, it has been shown that cellular integrins α2β1, α4β1 and αXβ2 are involved in rotavirus cell entry. As receptor usage is a major determinant of virus tropism, the levels of cell surface expression of these integrins have now been investigated by flow cytometry on cell lines of human (Caco-2, HepG2, RD, K562) and monkey (MA104, COS-7) origin in relation to cellular susceptibility to infection with monkey and human rotaviruses. Cells supporting any replication of human rotaviruses (RD, HepG2, Caco-2, COS-7 and MA104) expressed α2β1 and (when tested) αXβ2, whereas the non-permissive K562 cells did not express α2β1, α4β1 or αXβ2. Only RD cells expressed α4β1. Although SA11 grew to higher titres in RD, HepG2, Caco-2, COS-7 and MA104 cells, this virus still replicated at a low level in K562 cells. In all cell lines tested, SA11 replicated to higher titres than did human strains, consistent with the ability of SA11 to use sialic acids as alternative receptors. Levels of cell surface α2 integrin correlated with levels of rotavirus growth. The α2 integrin relative linear median fluorescence intensity on K562, RD, COS-7, MA104 and Caco-2 cells correlated linearly with the titre of SA11 produced in these cells at 20 h after infection at a multiplicity of 0·1, and the data best fitted a sigmoidal dose–response curve (r2=1·00, P=0·005). Thus, growth of rotaviruses in these cell lines correlates with their surface expression of α2β1 integrin and is consistent with their expression of αXβ2 and α4β1 integrins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a spinning metal wire collector was employed to continuously collect polyacrylonitrile (PAN) nanofibers produced by a disc fiber generator and coil them around a polyethylene terephthalate (PET) yarn. The obtained composite yarns exhibited a core/shell structure (PET yarn/PAN nanofibers) with nanofibers orderly arranged on the surface of the PET yarn. The electric field analysis showed that the position of metal wire had insignificant effect on the formed electric field and high intensity electric field was formed at the disc circumferential area, which provided a constant electric field for the production of uniform nanofibers. The spinning solution, spinning speed of metal wire, and winding speed were found to play an important role in producing good quality nanofiber yarns, in terms of morphology, strength, and productivity. Pure nanofiber yarns were obtained after dissolving the core yarns in a proper solvent. This method has shown potential for the mass production of nanofiber yarns for industrial applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show how in-line Raman spectroscopy can be used to monitor both reactant and product concentrations for a heterogeneously catalysed Suzuki cross reaction operating in continuous flow. The flow system consisted of an HPLC pump to drive a homogeneous mixture of the reactants (4-bromobenzonitrile, phenylboronic acid, and potassium carbonate) through an oven heated (80°C) palladium catalyst immobilised on a silica monolith. A custom built PTFE in-line flow cell with a quartz window enabled the coupling of an Ocean Optics Raman spectrometer probe to monitor both the reactants and product (4-cyanobiphenyl). Calibration was based on obtaining multivariate spectral data in the range 1530 cm–1 and 1640 cm–1 and using partial least-squares regression (PLSR) to obtain a calibration model which was validated using gas chromatography–mass spectrometry (GCMS) analysis. In-line Raman monitoring of the reactant and product concentrations enable (i) determination of reaction kinetic information such as the empirical rate law and associated rate constant and (ii) optimisation of either the product conversion (61 % at 0.02 mL min–1 generating 17 g h–1) or product yield (14 % at 0.24 mL min–1 generating 53 g h–1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly scalable and efficient flow-system has been developed to perform the catalyzed acetylation of alcohols and phenols, such as salicylic acid, at room temperature in excellent yield. The volumetric throughput and the amount of product can be increased simply by increasing the diameter of a versatile catalytic 12-tungstosilicic acid-supported, silica monolith can be used to increase the quantity of product produced without having to changeing the optimal operatingreaction conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate parameter estimation is important for reliable rainfall-runoff modeling. Previous studies emphasize that a sufficient length of continuous events is required for model calibration to overcome the effect of initial conditions. This paper investigates the feasibility of calibrating rainfall-runoff models over a number of limited storm flow events. For a subcatchment having a moderate influence from initial soil moisture conditions, this study shows that rainfall-runoff models could still be calibrated reliably over a set of representative events provided that the events cover a wide range of peak flow, total runoff volume, and initial soil moisture conditions. This approach could provide an alternative calibration strategy for a small watershed that has a limited data length but consists of runoff events with a wide range of magnitudes. Compared to continuous-event calibration, event-based calibration appears to perform better in simulating the overall shape of hydrograph, peak flow and time to peak. However, continuous-event calibration was found to be more reliable in providing runoff volume, suggesting that continuous-event calibration should still be used when runoff volume is the main concern of a study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the effect of different patterns of high-frequency stimulation at the nucleus accumbens shell on ethanol preference and circadian locomotor activity in adult male alcohol preferring (P) and nonpreferring (NP) rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The internet age has fuelled an enormous explosion in the amount of information generated by humanity. Much of this information is transient in nature, created to be immediately consumed and built upon (or discarded). The field of data mining is surprisingly scant with algorithms that are geared towards the unsupervised knowledge extraction of such dynamic data streams. This chapter describes a new neural network algorithm inspired by self-organising maps. The new algorithm is a hybrid algorithm from the growing self-organising map (GSOM) and the cellular probabilistic self-organising map (CPSOM). The result is an algorithm which generates a dynamically growing feature map for the purpose of clustering dynamic data streams and tracking clusters as they evolve in the data stream.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 Light-load exercise training with blood flow restriction (BFR) increases muscle strength and size. However, the hemodynamics of BFR exercise appear elevated compared with non-BFR exercise. This questions the suitability of BFR in special/clinical populations. Nevertheless, hemodynamics of standard prescription protocols for BFR and traditional heavy-load exercise have not been compared. We investigated the hemodynamics of two common BFR exercise methods and two traditional resistance exercises. Twelve young males completed four unilateral elbow flexion exercise trials in a balanced, randomized crossover design: (a) heavy load [HL; 80% one-repetition maximum (1-RM)]; (b) light load (LL; 20% 1-RM); and two other light-load trials with BFR applied (c) continuously at 80% resting systolic blood pressure (BFR-C) or (d) intermittently at 130% resting systolic blood pressure (BFR-I). Hemodynamics were measured at baseline, during exercise, and for 60-min post-exercise. Exercising heart rate, blood pressure, cardiac output, and rate–pressure product were significantly greater for HL and BFR-I compared with LL. The magnitude of hemodynamic stress for BFR-C was between that of HL and LL. These data show reduced hemodynamics for continuous low-pressure BFR exercise compared with intermittent high-pressure BFR in young healthy populations. BFR remains a potentially viable method to improve muscle mass and strength in special/clinical populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is concerned with the problem of finite-time stabilization for some nonlinear stochastic systems. Based on the stochastic Lyapunov theorem on finite-time stability that has been established by the authors in the paper, it is proven that Euler-type stochastic nonlinear systems can be finite-time stabilized via a family of continuous feedback controllers. Using the technique of adding a power integrator, a continuous, global state feedback controller is constructed to stabilize in finite time a large class of two-dimensional lower-triangular stochastic nonlinear systems. Also, for a class of three-dimensional lower-triangular stochastic nonlinear systems, a recursive design scheme of finite-time stabilization is given by developing the technique of adding a power integrator and constructing a continuous feedback controller. Finally, a simulation example is given to illustrate the theoretical results. © 2014 John Wiley & Sons, Ltd.