87 resultados para Cyber-physical energy system


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Governments in Australia are faced with policy implementation that mandates higher energy efficient housing (Foran, Lenzen & Dey 2005). To this effect, the National Construction Code (NCC) 2013 stipulates the minimum energy performance for residential buildings as 114MJ/m2 per annum or 6 stars on an energy rating scale. Compliance with this minimum is mandatory but there are several methods through which residential buildings can be rated to comply with the deemed to satisfy provisions outlined in the NCC. FirstRate5 is by far the most commonly used simulation software used in Victoria, Australia. Meanwhile, Building Information Modelling (BIM), using software such as ArchiCAD has gained a foothold in the industry. The energy simulation software within ArchiCAD, EcoDesigner, enables the reporting on the energy performance based on BIM elements that contain thermal information. This research is founded on a comparative study between FirstRate5 and EcoDesigner. Three building types were analysed and compared. The comparison finds significant differences between simulations, being, measured areas, thermal loads and potentially serious shortcomings within FirstRate5, that are discussed along with the future potential of a fully BIM-integrated model for energy rating certification in Victoria. © 2014, The Association for Computer-Aided Architectural Design Research in Asia (CAADRIA), Hong Kong.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a new distributed multi-agent scheme for reactive power management in smart coordinated distribution networks with renewable energy sources (RESs) to enhance the dynamic voltage stability, which is mainly based on controlling distributed static synchronous compensators (DSTATCOMs). The proposed control scheme is incorporated in a multi-agent framework where the intelligent agents simultaneously coordinate with each other and represent various physical models to provide information and energy flow among different physical processes. The reactive power is estimated from the topology of distribution networks and with this information, necessary control actions are performed through the proposed proportional integral (PI) controller. The performance of the proposed scheme is evaluated on a 8-bus distribution network under various operating conditions. The performance of the proposed scheme is validated through simulation results and these results are compared to that of conventional PI-based DSTATCOM control scheme. From simulation results, it is found that the distributed MAS provides excellence performance for improving voltage profiles by managing reactive power in a smarter way.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The vision of a smart grid is to provide a modern, resilient, and secure electric power grid as it boasts up with a highly reliable and efficient environment through effective use of its information and communication technology (ICT). Generally, the control and operation of a smart grid which integrate the distributed energy resources (DERs) such as, wind power, solar power, energy storage, etc., largely depends on a complex network of computers, softwares, and communication infrastructure superimposed on its physical grid architecture facilitated with the deployment of intelligent decision support system applications. In recent years, multi-agent system (MAS) has been well investigated for wide area power system applications and specially gained a significant attention in smart grid protection and security due to its distributed characteristics. In this chapter, a MAS framework for smart grid protection relay coordination is proposed, which consists of a number of intelligent autonomous agents each of which are embedded with the protection relays. Each agent has its own thread of control that provides it with a capability to operate the circuit breakers (CBs) using the critical clearing time (CCT) information as well as communicate with each other through high speed communication network. Besides physical failure, since smart grid highly depends on communication infrastructure, it is vulnerable to several cyber threats on its information and communication channel. An attacker who has knowledge about a certain smart grid communication framework can easily compromise its appliances and components by corrupting the information which may destabilize a system results a widespread blackout. To mitigate such risk of cyber attacks, a few innovative counter measuring techniques are discussed in this chapter.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It is not clear if higher levels of cardiorespiratory fitness are associated with lower hypothalamo-pituitary adrenal (HPA) axis and sympatho-adrenal medullary (SAM) system reactivity to psychological stress in women. The association between cardio-metabolic risk markers and acute physiological responses to psychological stress in women who differ in their cardiorespiratory fitness status has also not been investigated. Women with high (n = 22) and low (n = 22) levels of fitness aged 30-50 years (in the mid-follicular phase of the menstrual cycle) were subjected to a Trier Social Stress Test (TSST) at 1500 h. Plasma concentrations of cortisol, adrenaline (Adr), noradrenaline (NA), and dopamine (DA) were measured in samples collected every 7-15 min from 1400 to 1700 h. Heart rate and blood pressure were measured at the same time points. Low-fit women had elevated serum triglyceride, cholesterol/HDL ratio, fasting glucose, and HOMA-IR levels compared with high-fit women. While cortisol, Adr, NA, HR, and blood pressure all demonstrated a significant response to the TSST, the responses of these variables did not differ significantly between high- and low-fit women in response to the TSST. Dopamine reactivity was significantly higher in the low-fit women compared with high-fit women. There was also a significant negative correlation between VO2 max and DA reactivity. These findings suggest that, for low-fit women aged 30-50 years, the response of HPA axis and SAM system to a potent acute psychological stressor is not compromised compared to that in high-fit women.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the impact of large penetration of wind power on the transient stability through a dynamic evaluation of the critical clearing times (CCTs) by using intelligent agent-based approach. A decentralised multi-agent-based framework is developed, where agents represent a number of physical device models to form a complex infrastructure for computation and communication. They enable the dynamic flow of information and energy for the interaction between the physical processes and their activities. These agents dynamically adapt online measurements and use the CCT information for relay coordination to improve the transient stability of power systems. Simulations are carried out on a smart microgrid system for faults at increasing wind power penetration levels and the improvement in transient stability using the proposed agent-based framework is demonstrated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to assess the validity of a GPS tracking system to estimate energy expenditure (EE) during exercise and field sport locomotor movements. Twenty-seven participants each completed one 90 minute exercise session on an outdoor synthetic futsal pitch. During the exercise session participants wore a 5 Hz GPS unit interpolated to 15 Hz (SPI HPU, GPSports Pty Ltd, Australia) and a portable gas analyser (Metamax® 3B, Cortex Pty Ltd, Germany) which acted as the criterion measure of EE. The exercise session was comprised of alternating five minute exercise bouts of randomised walking, jogging, running or a field sport circuit (x3) followed by 10 minutes of recovery. One-way ANOVA showed significant (p<0.01) and very large underestimations between GPS metabolic power derived EE and VO2 derived EE for all field sport circuits (% difference ≈ -44%). No differences in EE were observed for the jog (7.8%) and run (4.8%) while very large overestimations were found for the walk (43.0%). The GPS metabolic power EE over the entire 90 minute session was significantly lower (p<0.01) than the VO2 EE, resulting in a moderate underestimation overall (-19%). The results of this study suggest that a GPS tracking system using the metabolic power model of EE does not accurately estimate EE in field sport movements or over an exercise session consisting of mixed locomotor activities interspersed with recovery periods; however is able to provide a reasonably accurate estimation of EE during continuous jogging and running.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Energy consumption in heating and cooling around the world has been a major contributor to global warming. Hence, many studies have been aimed at finding new techniques to save and control energy through energy efficient measures. Most of this energy is used in residential, agricultural and commercial buildings. It is therefore important to adopt energy efficiency measures in these buildings through new technologies and novel building designs. These new building designs can be developed by employing various passive cooling systems. Earth pipe cooling is one of these which can assist to save energy without using any customary mechanical units. This paper investigates the earth pipe cooling performance in a hot humid subtropical climate of Rockhampton, Australia. A thermal model is developed using ANSYS Fluent for measuring its performance. Impacts of air velocity, air temperature, relative humidity and soil temperature on room cooling performance are also assessed. A temperature reduction of around 2 °C was found for the system. This temperature reduction contributed to an energy saving of a maximum of 866.54 kW (8.82%) per year for a 27.23 m3 room.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Today’s power system network is more complex with enhanced responsibility to maintain reliable, stable and quality supply of power at transmission and distribution level. Maintaining grid balance is a bigger issue, in case of any unexpected generation shortage or grid disturbance or any participation of an intermittent nature of renewable energy sources like wind and solar power in the energy mix. In order to compensate such imbalance and improve reliability, and stability of power system, an energy storage system (ESS) can be considered as a vital solution. Also ESS can be used to mitigate associated issues of renewable energy sources while integration into the power system network. Thus ESS supports to get a reduction in greenhouse gas (GHG) emissions by means of integrating more renewable energy sources to the grid effectively. There are various types of Energy Storage (ES) technologies which are being used in power systems network for large scale (MW) to small scale (KW) level. Based on the type and characteristics, each storage technology is suitable for a particular role of applications. This paper presents an extensive review study on various types of ES technologies in characteristics and applications point of view. It also demonstrates various applications of ESS in detail. Finally, with the aid of ES-selectTM tool software, a feasibility analysis has been carried out to identify a suitable ES technology for appropriate applications at different grid locations and also helps to develop a smart hybrid storage system for grid applications in future.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Accurate measurement of physical activity is a pre-requisite to monitor population physical activity levels and design effective interventions. Global Positioning System (GPS) technology offers potential to improve the measurement of physical activity. This paper 1) reviews the extant literature on the application of GPS to monitor human movement, with a particular emphasis on free-living physical activity, 2) discusses issues associated with GPS use, and 3) provides recommendations for future research. Overall findings show that GPS is a useful tool to augment our understanding of physical activity by providing the context (location) of the activity and used together with Geographical Information Systems can provide some insight into how people interact with the environment. However, no studies have shown that GPS alone is a reliable and valid measure of physical activity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the control and charge management strategy of a photovoltaic system (PV) with plug-in hybrid electric vehicle (PHEV) as energy storage. The hybrid energy storage system (HESS) of PHEV consists of battery and supercapacitor. A simulation model for the PV system with PHEV energy storage has been developed using Matlab/SimpowerSystems. The system consists of PV arrays, SEPIC dc-dc converter with maximum power point tracking (MPPT), hybrid battery-supercapacitor energy storage with bidirectional dc-dc converter and inverter for grid connection. A charge management algorithm for the hybrid energy storage system is proposed to control the power flows among the PV system, energy storage and the grid. Results show that the proposed power management algorithm can control the power flows in an efficient manner.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Increasing the application of technologies for harvesting waste heat could make a significant contribution to sustainable energy production. Thermoelectrochemical cells are one such emerging technology, where the thermal response of a redox couple in an electrolyte is used to generate a potential difference across a cell when a temperature gradient exists. The unique physical properties of ionic liquids make them ideal for application as electrolytes in these devices. One of the keys to utilizing these media in efficient thermoelectrochemical cells is achieving high Seebeck coefficients, Se: the thermodynamic quantity that determines the magnitude of the voltage achieved per unit temperature difference. Here, we report the Se and cell performance of a cobalt-based redox couple in a range of different ionic liquids, to investigate the influence of the nature of the IL on the thermodynamics and cell performance of the redox system. The results reported include the highest Se to-date for an IL-based electrolyte. The effect of diluting the different ILs with propylene carbonate is also reported, which results in a significant increase in the output powers and current densities of the device.