193 resultados para Almost Contact Manifold


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To review the effects of contact lenses on the corneal surface.

Methods: A review of the literature and in-house research of corneal staining and its various forms of presentation.

Results: Corneal staining manifests in many different forms. The severity of staining or insult of the cornea is usually determined by the extent (area of coverage), density, and depth. The cause of staining is multifactorial, and its location is often linked to the type of lens that is being worn, the solution used to clean/disinfect the lens, the state of hydration of the soft lens, and the state of the cornea that has been affected by the lens.

Conclusions: Sodium fluorescein dye effectively highlights corneal integrity changes referred to as corneal staining. This review describes the manifestations, the cause, the mechanisms, and the methods of remediation of corneal staining.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Tear meniscus height (TMH) is an indirect measurement of tear film volume. This study investigated the temporal changes in the TMH during the blink interval in the morning (8–9 am) and at the end of the day (5–6 pm) in both soft contact lens (CL) and nonlens wearers (NLW).

Methods: Fifty participants (25 CL; 25 NLW) were evaluated for their subjective symptoms, TMH, noninvasive break up time, and bulbar hyperemia at the am and pm visits on the same day. The TMH was measured at set intervals between 2 and 15 sec during the blink interval, using an optical coherence tomographer.

Results: The NLW group revealed no changes in a variety of symptoms during the day, whereas the CL group reported an increase in dryness (P=0.03) and grittiness (P=0.02) over the day. For both groups, the TMH and calculated tear meniscus volume revealed lower values immediately after the blink and increased progressively afterwards, mainly due to reflex tearing. The am tear meniscus volume values tended to be higher than the pm values for both groups, but this was not significant (NLW P=0.13; CL P=0.82). Noninvasive break up time deteriorated during the day for both groups but was only significant for the CL group (P=0.002), whereas bulbar hyperemia revealed no statistically significant change for either group.

Conclusions: Reflex tearing may play a substantial role in the TMH differences observed over the blink interval. Standardization of the time when a TMH measurement is performed will be valuable in comparing tear film clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether the refractive index (RI) of a soft contact lens can be evaluated using refractometry while the lens remains on the eye and to compare this with more traditional ex vivo RI measurements.

Methods: A slitlamp apparatus was modified to incorporate a customized Atago hand refractometer. With a double-masked study design, nine adapted symptomatic soft contact lens wearers wore a contact lens in each eye (lotrafilcon B and etafilcon A) in a randomized order. In vivo RI was determined from the relative Brix scale measurements immediately after lens insertion and after 1 and 10 hr of lens wear. Ex vivo refractometry was performed after 10 hr of lens wear for comparison. Means ± standard errors of the means are reported.

Results: In vivo RI values at baseline were 1.422 ± 0.0004 (lotrafilcon B) and 1.405 ± 0.0021 (etafilcon A); after 1 hr of lens wear, values were 1.423 ± 0.0006 and 1.408 ± 0.0007, respectively; and after 10 hr of lens wear, values were 1.424 ± 0.0004 and 1.411 ± 0.0010, respectively. Ex vivo RI values at the end of the 10 hr wearing period were 1.424 ± 0.0003 (lotrafilcon B) and 1.412 ± 0.0017 (etafilcon A). The change in in vivo RI across the day was statistically significant for the etafilcon A lens (repeated-measures analysis of variance, P<0.01) but not for the lotrafilcon B lens (P>0.05).

Conclusions: This novel adaptation of refractometry was able to measure the RI of soft contact lenses during wear (without lens removal). End of day RI measurements using in vivo and ex vivo refractometry were comparable with each other. Future work is required to determine whether this in vivo method can improve our understanding of the relationships between soft contact lens RI, hydration, on-eye lens performance, and symptomology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To establish if evaluations of multifocal contact lens performance conducted at dispensing are representative of behavior after a moderate adaptation period.

Methods: Eighty-eight presbyopic subjects, across four clinical sites, wore each of four multifocal soft contact lenses (ACUVUE BIFOCAL, Focus Progressives, Proclear Multifocal, and SofLens Multifocal) for 4 days of daily wear. Comprehensive performance assessments were conducted at dispensing and after 4 days wear and included the following objective metrics: LogMAR acuity (contrast, 90% and 10%; illumination, 250 and 10 cd/m2; distance, 6 m, 100 cm, and 40 cm), stereopsis (RANDOT), reading critical print size and maximum speed and range of clear vision at near. Subjective assessments were made, with 100-point numerical rating scales, of comfort, ghosting (distance, near), visual quality (distance, intermediate, and near), and the appearance of haloes. At two sites, subjects (n = 39) also rated visual fluctuation (distance, intermediate, and near), facial recognition, and overall satisfaction.

Results: Among the objective variables, significant differences (paired t test, P<0.05) between dispensing and 4 days were found only for range of clear vision at near (2.9 ± 2.0 cm; mean difference ± standard deviation) and high contrast near acuity in low illumination (-0.013 ± 0.011 LogMAR). With the exception of insertion comfort, all subjective variables showed significant decrements over the same period. Overall satisfaction declined by an average of 10.9 ± 5.1 points.

Conclusions: Early assessment is relatively unrepresentative of performance later on during multifocal contact lens wear. Acuity based measures of vision remain substantially unchanged over the medium term, apparently because these metrics are insensitive indicators of performance compared with subjective alternatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye.

Methods: Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits.

Results: Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having good or excellent wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments.

Conclusions: Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

First introduced late in 1987 the Acuvue lens was originally launched as an extended-wear lens, though it soon became adapted to daily wear. It received an FDA licence for daily wear in the USA in 1990.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contact lens practitioner and patient present a specific case for the study of non-compliance in areas such as hygiene, solution use, appointment attendance and wearing times. Education is one of the factors thought to influence compliance among patients in general health care situations and contact lens practitioners are encouraged to educate patients in the care and maintenance of contact lenses. A prospective, randomized, controlled and double masked study was performed to assess the effect of a‘compliance enhancement strategy’ on levels of compliance among contact lens wearers over twelve months. Eighty experienced contact lens patients were randomly allocated to two experimental groups. A standard level of contact lens instruction was applied to the first group and in addition the compliance enhancement strategy was applied to patients assigned to the second group. The strategy consisted of extra education for patients using a video, booklets, posters, a checklist and a health care contract. Patients were given free supplies of RelMu multipurpose solution and Medalist 38 soft contact lenses IBausch and Lomb, Rochester. New York). Compliance levels were assessed at a twelve month aftercare appointment by demonstration and questionnaire. The results indicate that the compliance enhancement strategy had little significant effect on the compliance levels of the patients to whom it was applied. The population of contact lens wearers were generally very compliant and the contact lenses and care regimen were clinically successful. The possibility that the assessment of non–compliance was not adequately sensitive to highlight small differences in non-compliant, behaviour is discussed. The standard level of eduction applied to this sample of contact lens patients was adequate to ensure generally high levels of compliance with the simple care and maintenance regimen recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To determine the types of contact lenses prescribed for infants (aged 0 to 5 years), children (6 to 12 years), and teenagers (13 to 17 years) around the world.

Methods. Up to 1000 survey forms were sent to contact lens fitters in each of 38 countries between January and March every year for 5 consecutive years (2005 to 2009). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form.

Results. Data were received relating to 105,734 fits [137 infants, 1,672 children, 12,117 teenagers, and 91,808 adults (age ≥18 years)]. The proportion of minors (<18 year old) fitted varied considerably between nations, ranging from 25% in Iceland to 1% in China. Compared with other age groups, infants tend to be prescribed a higher proportion of rigid, soft toric, and extended wear lenses, predominantly as refits for full-time wear, and fewer daily disposable lenses. Children are fitted with the highest proportion of daily disposable lenses and have the highest rate of fits for part-time wear. Teenagers have a similar lens fitting profile to adults, with the main distinguishing characteristic being a higher proportion of new fits. Orthokeratology fits represented 28% of all contact lenses prescribed to minors.

Conclusions. Patterns of contact lens prescribing to infants and children are distinctly different to those of teenagers and adults in a number of respects. Clinicians can use the data presented here to compare their own patterns of contact lens prescribing to minors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To assess eye care practitioners (ECPs) recommendations for replacement frequency (RF) of silicone hydrogel (SH) and daily disposable (DD) lenses in Canada and the U.S. and to compare noncompliance (NC) with manufacturer recommended RF by the ECP and patient, and the reasons given for NC.

Methods. Invitations to participate were sent by e-mail to ECPs in Canada and the U.S. Twenty patient surveys were sent to 420 ECPs, and 2232 eligible surveys were received from 216 ECPs (26% Canada, 74% U.S.). Questions related to patient demographics, lens type, wearing patterns, ECP instructions for RF, and actual patient RF. ECPs provided lens information and their recommendation for RF after the surveys were completed and sealed in envelopes. Responses were anonymous.

Results. DD accounted for 18% (Canada) vs. 16% (U.S.) of wearers (p > 0.05); 35% (Canada) vs. 45% (U.S.) wore 2-week replacement SH (2WR; p = 0.011); and 47% (Canada) vs. 39% (U.S.) wore 1-month replacement SH (1MR) lenses (p = 0.025). Thirty-four percent (Canada) vs. 18% (U.S.) of ECPs recommended longer RFs than the manufacturer recommended RF for 2WR lens wearers (p < 0.001); 6% (Canada) vs. 4% (U.S.) for DD wearers; and 2% (Canada) vs. 1% (U.S.) for 1MR lens wearers. NC rates for actual RFs reported by patients were not different between countries (p > 0.05) and were lowest for DD (13% Canada, 12% U.S.), followed by 1MR (33% Canada, 28% U.S.). The highest NC rates were with 2WR (50% Canada, 52% U.S.). The most frequent reason for NC with 2WR and 1MR was “forgetting which day to replace lenses” (54% Canada, 53% U.S.) and in DD wearers “to save money” (56% Canada, 29% U.S., p < 0.001).

Conclusions. 1MR lenses are more frequently prescribed in Canada. ECPs in Canada were NC with 2WR lenses more frequently than U.S. ECPs, but patient NC rates were the same in both countries for all lens types. ECP and patient NC rates were highest for 2WR lens wearers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. Little is known about the contact lens prescribing habits of optometrists in North America. The purpose of this survey was to obtain data on the types of lenses and solutions prescribed by Canadian optometrists.

Methods. One thousand Canadian optometrists were surveyed annually over seven consecutive years (2000 to 2006; n = 7000) on their contact lens prescribing preferences. Each survey requested a range of information about the contact lenses prescribed to the first 10 patients after its receipt.

Results. Over this time period, 1008 (14.4%) of the surveys were returned, providing data on 9383 fits. During the seven-year period, the ratio of male:female fits was 1:2 (3123:6217, 43 not reported), with a mean age of 31.3 ± 13.6 years (range 2 to 82 years). The ratio of new fits to refits was 2:3 (3780:5518, 85 not reported), with 91.3% of all fits being soft contact lenses (SCL). Of the SCL fits, 59.5% were spherical, 28.5% toric, 9.7% multifocal, and 2.3% cosmetic tints. Gas permeable (GP) fits were 46.6% spherical, 18.6% toric, 19.5% multifocal, and 6.6% were for orthokeratology (OK). Over the seven-year period, SCL prescribed for continuous wear (CW) increased from 3.2% to 14.3% between 2000 and 2004 and reduced to 8.1% in 2006, for all fits. The use of mid-water content (MWC) materials decreased from 34.6% to 2.7% and the use of silicone hydrogel (SH) lenses increased from 61.4% to 96.2%, for all CW fits. GP lens continuous wear increased from 0.7% to 30.6% of all GP lens fits by 2006. Daily wear (DW) of SH lenses decreased from 49.6% (2000) to 33.7% (2004) and then increased to 86.1% in 2006, for SH fits. MWC SCL fit on a monthly planned replacement (PR) basis reduced in popularity over the seven-year period (75.0% to 39.9%) and in 2006 more patients were fit overall with SH lenses (42.9%). The use of non-PR SCL declined from 20.5% to 4.5% of all fits. Fitting of low-water content lenses also declined (15.1% to 7.0%). High-water content (5.4% to10.2%) and SH lenses (5.4% to 42.9%) both increased. By 2006, the majority of GP lenses fit were with high Dk (HDK) materials (50.3%).

Conclusions. The preferred contact lens modality for Canadian optometrists appears to be DW SCL, which are replaced monthly. The proportion of lenses used for CW peaked in 2004, with SH SCL being the preferred material. The market share for GP lenses remains relatively unchanged, with an increasing proportion used for OK and CW. The launch of DW SH lenses in 2004 resulted in a marked increase in their reported fits, with a similar effect following the launch of a HDK GP lens material for CW.