161 resultados para pilot


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Placements as a form of Work Integrated Learning are widely recognised for the positive impact they have on improving student employability and work readiness. Students can maximise strengths, improve areas of weakness, and develop a strong understanding of the requirements of their chosen field within the confines of a well monitored and rich learning environment. Assessment Centres (ACs) are commonly used in corporate settings for recruitment, selection and more recently to provide developmental feedback to participants. Based on a recent literature review, the present the present project evaluates the application of AC methodology as a developmental tool within the placement milieu. The review, which is also included the current conference proceedings details the benefits of utilising the AC process forming the impetus for the present pilot (Sturre; von Treuer & Keele 2010).
Aims: The primary aim of the paper was to evaluate the application of AC methodology as a tool for measuring and subsequently enhancing professional competencies in a sample of postgraduate students in organisational psychology (n=15).
Method: A longitudinal design was utilised with numerous evaluation points from placement stakeholders. This paper presents the first wave of findings. Students undertook a range of activities, including an in-tray exercise, role play, written report, leaderless group discussion and a personality assessment. Comprehensive feedback was provided by organisational psychologists who also fulfil the role of placement co-ordinators. With the assistance of Placement Co-ordinators, students prepared development plans relating to the competencies identified as requiring development. These plans were to be addressed and progress monitored during consecutive placements.
Results: Initial perceptions gathered from students regarding the AC process were very encouraging. Performance
evaluations collected to date, as measured by behaviourally based ratings scales completed by the students themselves and their workplace supervisors illustrate the positive effect of this methodology. The rigour and comprehensive techniques offered by the methodology enabled students to focus on and improve areas identified for development.
Conclusions: It is important to note that the present design formed a pilot study and as mentioned was undertaken with a limited sample. Future implementation is planned with larger samples, enabling a more comprehensive analysis of the methodology. Nevertheless, the methodology appears to provide a much needed strategy for the assessment and ongoing development of students prior to and during work placements. The application provides early intervention enabling students to address development needs with input from both university and organisational stakeholders based on an established, standardised process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pilot study was conducted to evaluate the usefulness of granisetron for the treatment of antidepressant induced sexual dysfunction in women. Twelve women with antidepressant induced sexual dysfunction (AISD) were assigned granisetron (n=5) or placebo (n=7) in a 14-day randomized, double-blind, placebo-controlled study. One participant in the granisetron group did not complete the study. Participants were assessed at baseline, day 7 and day 14 using the Feiger Sexual Function and Satisfaction Questionnaire and the Arizona Sexual Experience Scale. No statistical differences were measured at baseline or at endpoint between the granisetron or placebo group. This study did not produce evidence supporting the usefulness of granisetron in AISD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To identify and survey health care professionals (HCPs) attitudes to insulin pump therapy (CSII).

METHODS: Eight specialists were interviewed to explore the attitudes and beliefs about CSII. Responses were analysed thematically and used to inform the design of a new 22-item questionnaire: the Attitudes to Pump Therapy (APT) Survey. The APT was pilottested among 95 HCPs (54% male; 75.5% diabetologists/DSNs, 13.8% general practitioners) at the International Diabetes Federation (IDF) conference, 2006. Results were analysed using non-parametric statistics with bonferroni correction.

RESULTS: Analyses of interview data identified 9 themes: biomedical, perceived control of care/diabetes, technology, quality of life, financial resources, training, education & support, suitability, and evidence-base. Items were designed to reflect these themes with responses scored on a 5-point Likert scale (strongly agree—strongly disagree). No statistically significant differences
were found by gender, HCP speciality, country (and continent) of origin or proportion of patients using CSII. Most notable differences were found in relation to gross domestic product (GDP) and the potential for pump therapy to achieve tight blood glucose control (lower GDP = more agreement: p = 0.001), and result in diabetic ketoacidosis (DKA) (lower GDP = less agreement: p < 0.005). Ranked mean scores showed a split between biomedical/clinical items (N = 11) and items concerned with patient experience (N = 11). Attitudes about biomedical/clinical issues were generally clear (i.e. for 7/11 items, the mean score was “agree”) but less decisive about patient experience (i.e. for 8/11 items, the mean score was “neither agree nor disagree”).

CONCLUSION: Few subgroup differences existed, but those that did may be explained by lack of access to treatment (directly corresponding to GDP). Clinicians’ were generally clear in their attitudes regarding biomedical aspects but less so regarding patient experience. Research focusing on patient-reported outcomes is likely to offer clinicians a greater understanding of the patients’ perspective of insulin pump therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A three stage-treatment of domestic wastewater including anaerobic, anoxic and aerobic phases is employed in this study while a clarifier unit is replaced with a submerged membrane in the aerobic unit. The effects of operational parameters on the performance of a pilot scale submerged membrane bioreactor (SMBR) namely hydraulic retention time (HRT), ratio of return activated sludge (QRS), ratio of internal recycle (QIR), solid retention time (SRT) and dissolved oxygen (DO) are evaluated by simulations, using a hybrid model composed of TUDP model, oxygen transfer model, biofouling model due to extra-cellular polymeric substances (EPS) and turbulent shear model. The results showed that anaerobic HRT of 3 hours, anoxic HRT of 6 hours, QRS of 20% and QIR of 300 % are satisfactory in obtaining a high removal efficiency (>90%) of COD, NH4-N, P04-P as well as a less sludge production. An increase of sludge production causes an increase in EPS, which fouls the membrane surface and increase the cleaning cycle of membrane. Operation of 5MBR system at 2 mg/I of DO and 30 days of SRT can extend the membrane cleaning cycle dramatically. The membrane cleaning cycle however is strongly dependent on the initial and terminal specific fluxes and displays inverse power relationships to those fluxes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recirculating aquaculture systems (RAS) are essential for the reduction in fresh water usage as well as the discharge of nutrients along with aquaculture effluents. A RAS consisting of an anoxic reactor, a membrane bioreactor (MBR) and a UV-disinfection unit was used to process 10,000 L/d of aquaculture effluent providing high-quality treated water for recirculation to a Barramundi fish culture. The system maintained low levels of nitrate (<20 mg/L), nitrite (<3 mg/L) and ammonia (<0.6 mg/L) in the fish tank. Permeate from the membrane that was recirculated to the fish tank contained <21 mg/L of nitrate, <2 mg/L of nitrite and 0 mg/L of ammonia. However, the rate of fouling of the membrane in the MBR was around 1.47 kPa/d, and the membrane in the MBR required cleaning due to fouling after 16 days. Cleaning of the membrane was initiated when the TMP reached around 25 to 30 kPa. In order to reduce the rate of fouling, 500 mg of powdered activated carbon (PAC) per litre of MBR volume was introduced, which decreased the rate of fouling to 0.90 kPa/d. Cleaning of membrane was needed only after 31 days of operation while maintaining the treated effluent quality. Thus the frequency of cleaning could be halved due to the introduction of PAC into the MBR.