76 resultados para Photovoltaic power generation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a novel excitation control design to improve the voltage profile of power distribution networks with distributed generation and induction motor loads. The system is linearised by perturbation technique. Controller is designed using the linear-quadratic-Gaussian (LQG) controller synthesis method. The LQG controller is addressed with norm-bounded uncertainty. The approach considered in this paper is to find the smallest upper bound on the H∞ norm of the uncertain system and to design an optimal controller based on this bound. The design method requires the solution of a linear matrix inequality. The performance of the controller is tested on a benchmark power distribution system. Simulation results show that the proposed controller provides impressive oscillation damping compared to the conventional excitation controller.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the impact of different types of load models in distribution network with distributed wind generation. The analysis is carried out for a test distribution system representative of the Kumamoto area in Japan. Firstly, this paper provides static analysis showing the impact of static load on distribution system. Then, it investigates the effects of static as well as composite load based on the load composition of IEEE task force report [1] through an accurate time-domain analysis. The analysis shows that modeling of loads has a significant impact on the voltage dynamics of the distribution system with distributed generation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The abundance, availability, and climate-friendly characteristics of solar photovoltaic (PV) energy encourage nations around the globe to adopt it to assist in overcoming global warming as well as build a sustainable society for the future. The intermittent nature of solar energy generation and the associated power electronic inverters with connected consumer loads creates a number of potential challenges in integrating large-scale PV into the grid that affects power quality of the distribution networks. This paper investigates the impacts of varying PV integration into the grid through experimental and simulation studies. Initially, several experiments were conducted with varying PV penetration and load conditions using the Renewable Energy Integration Facility at CSIRO, Newcastle, Australia. Later, a simulation model was developed that mimics the experimental facility used at CSIRO to investigate the adverse impacts on integrating large-scale PV into the grid using the power system simulation software PSS Sincal. Experimental and simulation analyses clearly indicate that integration of PV into the grid causes power quality issues such as voltage instability, harmonic injection, and low power factor into the networks and the level of these impacts increases with the increase of PV penetration. © 2014 AIP Publishing LLC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, simulation and hardware implementation of Fuzzy Logic (FL) Maximum Power Point Tracking (MPPT) used in photovoltaic system with a direct control method are presented. In this control system, no proportional or integral control loop exists and an adaptive FL controller generates the control signals. The designed and integrated system is a contribution of different aspects which includes simulation, design and programming and experimental setup. The resultant system is capable and satisfactory in terms of fastness and dynamic performance. The results also indicate that the control system works without steady-state error and has the ability of tracking MPPs rapid and accurate which is useful for the sudden changes in the atmospheric condition. MATLAB/Simulink software is utilized for simulation and also programming the TMS320F2812 Digital Signal Processor (DSP). The whole system designed and implemented to hardware was tested successfully on a laboratory PV array. The obtained experimental results show the functionality and feasibility of the proposed controller.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, a nonlinear backstepping controller is designed for three-phase grid-connected solar photovoltaic (PV) systems to share active and reactive power. A cascaded control structure is considered for the purpose of sharing appropriate amount of power. In this cascaded control structure, the dc-link voltage controller is designed for balancing the power flow within the system and the current controller is designed to shape the grid current into a pure sinusoidal waveform. In order to balance the power flow, it is always essential to maintain a constant voltage across the dc-link capacitor for which an incremental conductance (IC) method is used in this paper. This approach also ensures the operation of solar PV arrays at the maximum power point (MPP) under rapidly changing atmospheric conditions. The proposed current controller is designed to guarantee the current injection into the grid in such a way that the system operates at a power factor other than unity which is essential for sharing active and reactive power. The performance of the proposed backstepping approach is verified on a three-phase grid-connected PV system under different atmospheric conditions. Simulation results show the effectiveness of the proposed control scheme in terms of achieving desired control objectives.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Maximum Power Point Tracking (MPPT) is an important concern in Photovoltaic (PV) systems. As PV systems have a high cost of energy it is essential that they are operated to extract the maximum possible power at all times. However, under non-uniform environmental conditions, which frequently arise in the outdoor environment, many MPPT techniques will fail to track the global peak power. This review paper discusses conventional MPPT techniques designed to operate under uniform environmental conditions and highlights why these techniques fail under non-uniform conditions. Following this, techniques designed specifically to operate under non-uniform environmental conditions are analysed and compared. Simulation results which compare the performance of the common Perturb and Observe (P&O) method, the Particle Swarm Optimisation (PSO) and the Simulated Annealing (SA) MPPT approaches under non-uniform environmental conditions are also presented. The research presented in this review indicates that there is no single technique which can achieve reliable global MPPT with low cost and complexity and be easily adapted to different PV systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, a new agent-based distributed reactive power management scheme is proposed to improve the voltage stability of energy distribution systems with distributed generation units. Three types of agents – distribution system agent, estimator agent, and control agent are developed within the multi-agent framework. The agents simultaneously coordinated their activities through the online information and energy flow. The overall achievement of the proposed scheme depends on the coordination between two tasks – (i) estimation of reactive power using voltage variation formula and (ii) necessary control actions to provide the estimated reactive power to the distribution networks through the distributed static synchronous compensators. A linear quadratic regulator with a proportional integrator is designed for the control agent in order to control the reactive component of the current and the DC voltage of the compensators. The performance of the proposed scheme is tested on a 10-bus power distribution network under various scenarios. The effectiveness is validated by comparing the proposed approach to the conventional proportional integral control approach. It is found that, the agent-based scheme provides excellent robust performance under various operating conditions of the power distribution network.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Partial shading is an unavoidable condition which significantly reduces the efficiency and stability of a photovoltaic (PV) system. When partial shading occurs the system has multiple-peak output power characteristics. In order to track the global maximum power point (GMPP) within an appropriate period a reliable technique is required. Conventional techniques such as hill climbing and perturbation and observation (P&O) are inadequate in tracking the GMPP subject to this condition resulting in a dramatic reduction in the efficiency of the PV system. Recent artificial intelligence methods have been proposed, however they have a higher computational cost, slower processing time and increased oscillations which results in further instability at the output of the PV system. This paper proposes a fast and efficient technique based on Radial Movement Optimization (RMO) for detecting the GMPP under partial shading conditions. The paper begins with a brief description of the behavior of PV systems under partial shading conditions followed by the introduction of the new RMO-based technique for GMPP tracking. Finally, results are presented to demonstration the performance of the proposed technique under different partial shading conditions. The results are compared with those of the PSO method, one of the most widely used methods in the literature. Four factors, namely convergence speed, efficiency (power loss reduction), stability (oscillation reduction) and computational cost, are considered in the comparison with the PSO technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This chapter presents an unbalanced multi-phase optimal power flow (UMOPF) based planning approach to determine the optimum capacities of multiple distributed generation units in a distribution network. An adaptive weight particle swarm optimization algorithm is used to find the global optimum solution. To increase the efficiency of the proposed scheme, a co-simulation platform is developed. Since the proposed method is mainly based on the cost optimization, variations in loads and uncertainties within DG units are also taken into account to perform the analysis. An IEEE 123 node distribution system is used as a test distribution network which is unbalanced and multi-phase in nature, for the validation of the proposed scheme. The superiority of the proposed method is investigated through the comparisons of the results obtained that of a Genetic Algorithm based OPF method. This analysis also shows that the DG capacity planning considering annual load and generation uncertainties outperform the traditional well practised peak-load planning.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Due to low electricity rates at nighttime, home charging for electric vehicles (EVs) is conventionally favored. However, the recent tendency in support of daytime workplace charging that absorbs energy produced by solar photovoltaic (PV) panels appears to be the most promising solution to facilitating higher PV and EV penetration in the power grid. This paper studies optimal sizing of workplace charging stations considering probabilistic reactive power support for plug-in hybrid electric vehicles (PHEVs), which are powered by PV units in medium voltage (MV) commercial networks. In this study, analytical expressions are first presented to estimate the size of charging stations integrated with PV units with an objective of minimizing energy losses. These stations are capable of providing reactive power support to the main grid in addition to charging PHEVs while considering the probability of PV generation. The study is further extended to investigate the impact of time-varying voltage-dependent charging load models on PV penetration. The simulation results obtained on an 18-bus test distribution system show that various charging load models can produce dissimilar levels of PHEV and PV penetration. Particularly, the maximum energy loss and peak load reductions are achieved at 70.17% and 42.95% respectively for the mixed charging load model, where the system accommodates respective PHEV and PV penetration levels of 9.51% and 50%. The results of probabilistic voltage distributions are also thoroughly reported in the paper.