78 resultados para Microfluidic


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A compact microfluidic device with 96 microchambers allocated within four circular units was designed and examined for cell distribution. In each unit, cells were distributed to the surrounding chambers radially from the center. The circular arrangement of the chambers makes the design simple and compact. A controllable and quantitative cell distribution is achievable in this device. This design is significant to the microfluidic applications where controllable distribution of cells in multipule microchambers is demanded.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A microfluidic dielectrophoresis platform consisting of curved microelectrodes was developed and integrated with a Raman spectroscopy system. The electrodes were patterned on a quartz substrate, which has insignificant Raman response, and integrated with a microfluidic channel that was imprinted in poly-dimethylsiloxane (PDMS). We will show that this novel integrated system can be efficiently used for the determination of suspended particle types and the direct mapping of their spatial concentrations. We will also illustrate the system's unique advantages over conventional optical systems. Nanoparticles of tungsten trioxide (WO3) and polystyrene were used in the investigations, as they are Raman active and can be homogeneously suspended in water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dielectrophoresis (DEP) utilizing a curved microelectrode pattern was developed and integrated with a Raman spectroscopy system. The electrodes were patterned on a Raman transparent quartz substrate, and integrated with a microfluidic channel in poly-dimethylsiloxane (PDMS). This integrated system can be efficiently used for the determination of suspended particles type and the direct mapping of their spatial concentrations. It will be demonstrated that the integration of Raman mapping with dielectrophoretically controlled WO3 particles can be used for studying suspended particles in situ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, an array of dielectrophoretic curved microelectrodes patterned in a microfluidic channel and integrated with a multimode rib polymeric waveguide is demonstrated. The microfluidic channel is infiltrated with suspended silica (SiO2) and tungsten trioxide (WO3) nanoparticles. The optofluidic system is found to be sensitive and responds not only to the infiltration of nanoparticle suspensions in the microfluidic channel, but also to the magnitude and frequencies of dielectrophoretic forces applied on the nanoparticles. The nanoparticles can be uniformly concentrated or repelled from the region between the curved microelectrode tips forming either a dense stream of flowing nanoparticles or a region void of nanoparticles in the evanescent sensitive region of the polymeric waveguide. The concentration and repulsion of nanoparticles from this region creates a refractive index gradient in the upper cladding of the polymeric waveguide. These conditions made it possible for light to either remain guided or be scattered as a function of dielectrophoretic settings applied on the nanoparticles. The results demonstrate that we successfully developed a novel tuneable polymeric waveguide based on dielectrophoretic assembly of nanoparticles suspended in fluids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dielectrophoresis, the induced motion of polarisable particles in non-homogenous electric field, has been proven as a versatile mechanism to transport, immobilise, sort and characterise micro/nano scale particle in microfluidic platforms. The performance of dielectrophoretic (DEP) systems depend on two parameters: the configuration of microelectrodes designed to produce the DEP force and the operating strategies devised to employ this force in such processes. This work summarises the unique features of curved microelectrodes for the DEP manipulation of target particles in microfluidic systems. The curved microelectrodes demonstrate exceptional capabilities including (i) creating strong electric fields over a large portion of their structure, (ii) minimising electro-thermal vortices and undesired disturbances at their tips, (iii) covering the entire width of the microchannel influencing all passing particles, and (iv) providing a large trapping area at their entrance region, as evidenced by extensive numerical and experimental analyses. These microelectrodes have been successfully applied for a variety of engineering and biomedical applications including (i) sorting and trapping model polystyrene particles based on their dimensions, (ii) patterning carbon nanotubes to trap low-conductive particles, (iii) sorting live and dead cells based on their dielectric properties, (iv) real-time analysis of drug-induced cell death, and (v) interfacing tumour cells with environmental scanning electron microscopy to study their morphological properties. The DEP systems based on curved microelectrodes have a great potential to be integrated with the future lab-on-a-chip systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the thermal analysis of liquid containing Al2O3 nanoparticles in a microfluidic platform using an infrared camera. The small dimensions of the microchannel along with the low flow rates (less than 120 μl min−1) provide very low Reynolds numbers of less than 17.5, reflecting practical parameters for a microfluidic cooling platform. The heat analysis of nanofluids has never been investigated in such a regime, due to the deficiencies of conventional thermal measurement systems. The infrared camera allows non-contact, three dimensional and high resolution capability for temperature profiling. The system was studied at different w/w concentrations of thermally conductive Al2O3 nanoparticles and the experiments were in excellent agreement with the computational fluid dynamics (CFD) simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Every field of knowledge has two aspects: a practice component, and research into the advancement of the discipline. Chemical education is the same. Chemical education research (CER) aims to evaluate improvements and innovation in practice and also investigate how students learn chemistry. Examples illustrate the scope of CER, with analogies to better well-known examples of research in chemistry.

One recurring theme in chemical education is the improvement of existing laboratory exercises, the development of new laboratory exercises, and the testing of the activities to ensure their scientific validity and robustness, and finally evaluation and feedback to assess the effectiveness of the experiment by students and teaching staff.

Another active area of research is the analysis of curriculum in terms of logical versus psychological progressions of topics order, and trials on better sequences of topics for better outcomes.

have lead to advances in chemistry, with microwave-assisted synthesis, microfluidic devices, and better spectrometers to name just a few. So too, advances in technology have changed the practice of chemical education.

Other CER has examined new uses for mobile phones, using podcasts to enhance lectures, as flashcards, or to access chemistry resources, student-created videos and photo blogs, and other advances in technology.

Yet another area of CER is in the development and validation of these survey instruments.

Research is about collecting proof to support or refute a hypothesis. Chemical education research is no different. Chemical education seeks to improve the learning of chemical science. Chemical education research collects data to evaluate whether a particular course of action is good or bad for learning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic liquid marbles, an encapsulation of liquid droplet with hydrophobic magnetic particles, show remarkable responsiveness to external magnetic force and great potential to be used as a discrete droplet microfluidic system. In this study, we presented the manipulation of a magnetic liquid marble under an external magnetic field and calculated the maximum frictional force, the magnetic force required for actuating the liquid marbles and the effective surface tension of the magnetic liquid marble, as well as the threshold volume for the transition from quasi-spherical to puddle-like shape. By taking advantage of the unique feature of being opened and closed reversibly, we have proven the encapsulated droplets can be detected optically with a reflection-mode probe. Combining the open-close and optical detection also enables to probe chemical reactions taking place within liquid marbles. These remarkable features offer a simple yet powerful alternative to conventional discrete microfluidic systems and may have wide applications in biomedical and drug discovery. © 2012 The Author(s).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current practice of designing microfluidic Lab-on-a-Chip (LoCs) limits reusing designs and makes sharing tasks among researchers difficult. One way to achieve that objective is to borrow best practices from engineering. Also it takes a lot of skills to design LoCs. Design-by-assembly in which a LoC can be designed by configuring, laying out subsystems can help new researchers to develop custom chips. Flexible, reusable, and rapid-prototyping-feasible LoC designs can be achieved by fabricated modular microfluidic blocks. However, challenging problems still persist, which limit the usefulness of prefabricated blocks. We propose software microfluidic modules (SoftMABs) based design technique to solve issues fabricated modules face. By configuring SoftMABs, integrating them, the new assembly of SoftMABs can form a 3D LoC design ready to be prototyped. The proposed method can make designing a complex LoC less challenging, and collaborating among laboratories easier. We created SoftMABs and designed a custom microfluidic chip by assembling SoftMABs like LEGOs, dragging-and-dropping them. Later we reconfigured them - by replacing a SoftMAB with another module - to make a new LoC. We believe this computeraided method is an interesting and useful LoC design technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polydimethylsiloxane (PDMS) fibers with unexpected elasticity were prepared by a modified core-shell electrospinning method using a commercially-available liquid PDMS precursor (Sylgard 184) and polyvinylpyrrolidone (PVP) as core and sheath materials, respectively. The liquid PDMS precursor was crosslinked in situ to form a solid core when the newly-electrospun core-sheath nanofibers were deposited onto a hot-plate electrode collector. After dissolving the PVP sheath layer off the fibers, net PDMS fibers showed larger average diameter than core-sheath fibers, with an average diameter around 1.35 μm. The tensile properties of both single fibers and fibrous mats were measured. Single PDMS fibers had a tensile strength and elongation at break of 6.0 MPa and 212%, respectively, which were higher than those of PDMS cast film (4.9 MPa, 93%). The PDMS fiber mat had larger elongation at break than the single PDMS fibers, which can be drawn up to 403% their original length. Cyclic loading tests indicated a Mullin effect on the PDMS fiber mats. Such a superior elastic feature was attributed to the PDMS molecular orientation within fibers and the randomly-orientated fibrous structure. Highly-elastic, ultrafine PDMS fibers may find applications in strain sensors, biomedical engineering, wound healing, filtration, catalysis, and functional textiles. © The Royal Society of Chemistry 2014.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes the manufacturing and characterisation of plano-convex miniaturised lenses using a CO2 laser engraving process in PMMA substrates. The technique allows for lenses to be fabricated rapidly and in a reproducible manner at depths of over 200 µm and for lens diameters of more than 3 mm. Experimental characterisation of the lens focal lengths shows good correlation with theory. The plano-convex lenses have been successfully embedded into capillary microfluidic systems alongside planar microlenses, allowing for a significant reduction of ancillary optics without a loss of detection sensitivity when performing fluorescence measurements. Such technology provides a significant step forward towards the portability of fluorescence- or luminescence-based systems for biological/chemical analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The role of circulating tumor cells (CTCs) in disease diagnosis, prognosis, monitoring of the therapeutic efficacy, and clinical decision making is immense and has attracted tremendous focus in the last decade. We designed and fabricated simple, flat channel microfluidic devices polydimethylsiloxane (PDMS based) functionalized with locked nucleic acid (LNA) modified aptamers (targeting epithelial cell adhesion molecule (EpCAM) and nucleolin expression) for quick and efficient capture of CTCs and cancer cells. With optimized flow rates (10 μl/min), it was revealed that the aptamer modified devices offered reusability for up to six times while retaining optimal capture efficiency (>90%) and specificity. High capture sensitivity (92%) and specificity (100%) was observed in whole blood samples spiked with Caco-2 cells (10-100 cells/ml). Analysis of blood samples obtained from 25 head and neck cancer patients on the EpCAM LNA aptamer functionalized chip revealed that an average count of 5 ± 3 CTCs/ml of blood were captured from 22/25 samples (88%). EpCAM intracellular domain (EpICD) immunohistochemistry on 9 oral squamous cell carcinomas showed the EpICD positivity in the tumor cells, confirming the EpCAM expression in CTCs from head and neck cancers. These microfluidic devices also maintained viability for in vitro culture and characterization. Use of LNA modified aptamers provided added benefits in terms of cost effectiveness due to increased reusability and sustainability of the devices. Our results present a robust, quick, and efficient CTC capture platform with the use of simple PDMS based devices that are easy to fabricate at low cost and have an immense potential in cancer diagnosis, prognosis, and therapeutic planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low-cost system to generate, control and detect electrochemiluminescence using a mobile smartphone is described. A simple tone-detection integrated circuit is used to switch power sourced from the phone's Universal Serial Bus (USB) 'On-The-Go' (OTG) port, using audible tone pulses played over the device's audio jack. We have successfully applied this approach to smartphones from different manufacturers and with different operating system versions. ECL calibrations of a common luminophore, tris(2,2′-bipyridine)ruthenium(II) ([Ru(bpy)3]2+), with 2-(dibutylamino)ethanol (DBAE) as a co-reactant, showed no significant difference in light intensities when an electrochemical cell was controlled by a mobile phone in this manner, compared to the same calibration generated using a conventional potentiostat. Combining this novel approach to control the applied potential with the measurement of the emitted light through the smart phone camera (using an in-house built Android app), we explored the ECL properties of a water-soluble iridium(III) complex that emits in the blue region of the spectrum. The iridium(III) complex exhibited superior co-reactant ECL intensities and limits of detection to that of the conventional [Ru(bpy)3]2+ luminophore.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a simple, environmentally friendly approach to fabricating superhydrophobic coatings with pH-induced wettability transition. The coatings are prepared from a mixture of silica nanoparticles and decanoic acid-modified TiO2. When the coating is applied on cotton fabric, the fabric turns superhydrophobic in air but superoleophilic in neutral aqueous environment. It is permeable to oil fluids but impermeable to water. However, when the coated fabric is placed in basic aqueous solution or ammonia vapor, it turns hydrophilic but underwater superoleophobic, thus allowing water to penetrate through but blocking oil. Therefore, such a unique, selective water/oil permeation feature makes the treated fabric have capability to separate either oil or water from a water-oil mixture. It may be useful for development of smart oil-water separators, microfluidic valves, and lab-on-a-chip devices.