137 resultados para silicone coating


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To investigate initial comfort and adaptation of currently successful low oxygen transmissibility soft lens wearers refitted with silicone hydrogel (SH) lenses for daily wear.

Methods. Fifty-five subjects were enrolled in a subject-masked 5-month clinical trial in which they wore 5 SH lenses in a randomized, crossover design. Comfort, burning, and dryness were rated on scales of 0 to 100 immediately on insertion and the time for lens settling was recorded. Symptoms were then rated at various times, using BlackBerry wireless communication devices (Research in Motion, Waterloo, Canada), during the day for 2 cycles of 2 weeks wear for each lens type.

Results. Comfort immediately on insertion varied between lens types (P=0.002). All lens types were reported by the subjects to have settled within 30 to 45 sec of insertion (P=0.14) and settled comfort was greater than comfort immediately on insertion (P<0.001). Comfort within the first hour of wear also varied between lens types (P=0.02). Comfort during the day decreased significantly for all lenses (P=0.001), but there was no difference between lenses (P=0.19) and no effect of lens age (P=0.15). The wearing times were greater with the SH lenses than the habitual lenses worn before study commencement (P=0.001). Overall performance of the lenses after 4 weeks was high, with no difference between lenses (P=0.45).

Conclusions. Initial comfort and adaptation to all SH lenses were good and no differences in the overall ratings were found between the 5 SH lenses investigated. Decreased comfort was noted later in the day with all lens types, but longer wearing times were reported with the SH lenses than previous hydroxyethyl methacrylate-based lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of rf-power in the range from 100 to 200 W on the electrochemical properties of TiN coatings deposited on 316L stainless steel was investigated by using various electrochemical techniques in a 3.5-wt\% NaCl solution. Surface analyses were also conducted to analyze the coating characteristics. X-ray diffraction (XRD) and atomic force microscopy (AFM) analyses confirmed that increasing the rf-power led to a preferred orientation of the TiN(200) microstructure and decreased the surface roughness. The potentiodynamic test results confirmed the passive behavior of all of the specimens with low passive current densities and demonstrated that the effective pitting resistance of the TiN coatings increased with increasing rf-power. The electrochemical impedance spectroscopy (EIS) tests showed that the TiN films deposited with high rf-power had excellent corrosion resistance during an immersion time of 720 h due to their high total resistance and low porosity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CrN films on a bipolar plate in polymer electrolyte membrane fuel cells have several advantages owing to their excellent corrosion resistance and mechanical properties. Three CrN samples deposited at various radio frequency (RF) powers by RF magnetron sputtering were evaluated under potentiodynamic, potentiostatic and electrochemical impedance spectroscopy conditions. The electrochemical impedance spectroscopy data were monitored for 168 h in a corrosive environment at 70 °C to determine the coating performance at +600 mVSCE under simulated cathodic conditions in a polymer electrolyte membrane fuel cell. The electrochemical behavior of the coatings increased with decreasing RF power. CrN films on the AISI 316 stainless steel substrate showed high protective efficiency and charge transfer resistance, i.e. increasing corrosion resistance with decreasing RF power. X-ray diffraction confirmed the formation of a CrN(200) preferred orientation at low RF power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess current recommendations by optometrists for replacement frequency (RF) of silicone hydrogels (SH) and daily disposable (DD) contact lenses in Canada, determine rates of non-compliance with recommendations by both the optometrist and patient, and investigate reasons for non-compliance.

Methods: Survey packages were sent to optometrists in Canada who had agreed to participate. Patients completed survey questions regarding demographics and contact lens wearing patterns, including recommended and actual contact lens RF. Optometrists were asked to provide lens information and their recommendation for RF. Fifty-eight optometrists returned 654 surveys, of which 578 were eligible for analysis.

Results: Seventy percent of patients were female with a median age of 32 years. Lens type distribution was 18% DD, 35% two-week SH, and 47% one-month SH. Six percent were worn for extended wear. Daily wear median wearing time was 12 hours/day, a median of five days/week for DD, seven days/week for SH (two-week and one-month). Optometrists’ recommendations were non-compliant with the manufacturers’ recommended RF for 6% of DD, 35% of two week, and 2% of one-month patients. Patients were non-compliant with recommendations from both the manufacturer and optometrist for 12% of DD, 43% of two-week, and 31% of one-month lens wearers. The most common reason for non-compliance was forgetting which day to replace lenses. Fifty-six percent thought a reminder system would help with compliance. A higher proportion of compliant patients followed the RF because of confidence in their optometrist.

Conclusions: Optometrists generally recommended RFs consistent with manufacturers’ recommendations for DD and one-month SH lenses but often recommended longer intervals for two-week SH lenses. Patients were most compliant when wearing DD lenses and least compliant when wearing two-week SH lenses. Communication between the patient and optometrists concerning the risks of non-compliance, or initiating a reminder system might improve compliance.