67 resultados para nanoindentation laboratory


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background
Undergraduate engineering students require exposure to an appropriate level of practical activities to complement the theory delivered in their course. This not only serves the purpose of catering to students’ different learning styles but in contributing to developing practical skills important to achieving an adequate level of job-readiness. The mode by which practical activities are implemented can vary widely across different units of study and different institutions. Electronics practicals within the School of Engineering at Deakin University have traditionally involved the construction and analysis of bread board circuits. Recently however, the practicals have changed to utilise modern computer-integrated Lab Volt FACET board equipment.


Purpose
This paper discusses electronics practicals using two very different types of laboratory equipment and reports on student perceived efficacy. The aim of the study is to gain an understanding of student perceptions so as to be able to refine the practicals to increase student engagement.

Design / method
This paper discusses two very different types of laboratory equipment employed in electronics practicals within the School of Engineering at Deakin University. This study focuses on students in electronics-related engineering disciplines and their perceived efficacy of the different equipment with the aim of providing valuable insight regarding student engagement. Survey data was collected from first and second year students who had completed successive classes using the different types of laboratory equipment.

Results
When compared with the electronics practicals and equipment previously used at Deakin University, the Lab Volt FACET boards provide a well-structured and resource efficient method for conducting practicals. The preliminary survey results indicate that there are mixed preferences for which type of laboratory equipment students perceive to be the better learning tool. The results also indicate that these perceptions appear to align with students in specific disciplines. These observations suggest that discipline specific characteristics of students are an important consideration in achieving improved student engagement and a positive learning experience.

Conclusions
The outcomes of the preliminary study suggest that there are discipline specific characteristics which affect students’ perceptions of the efficacy of laboratory equipment. These outcomes will assist Deakin’s School of Engineering to refine the use of the Lab Volt FACET board laboratory equipment to achieve improved student engagement. Future research will build upon these findings to investigate expectations of students in different disciplines and whether there is a difference in preferred learning and any correlation to student perceptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hysteresis energy decreased significantly as nanocrystalline NiTi shape memory alloy was under triangular cyclic nanoindentation loadings at high rate. Jagged curves evidenced discrete stress relaxations. With a large recovery state of maximum deformation in each cycle, this behavior concluded in several nucleation sites of phase transformation in stressed bulk. Additionally, the higher initial propagation velocity of interface and thermal activation volume, and higher levels of phase transition stress in subsequent cycles explained the monotonic decreasing trend of dissipated energy. In contrast, the dissipated energy showed an opposite increasing trend during triangular cyclic loadings at a low rate and 60âsec holding time after each unloading stage. Due to the isothermal loading rate and the holding time, a major part of the released latent heat was transferred during the cyclic loading resulting in an unchanged phase transition stress. This fact with the reorientation phenomenon explained the monotonic increasing trend of hysteresis energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results from experiments conducted in a 2m high flow compartment at large Reynolds numbers are reported in this paper. Flow entered the compartment through an opening at the base on one side of the compartment and exited from an opening at the bottom of the opposite wall of the compartment. A shear layer is formed at the boundary between the incoming flow and the ambient fluid in the compartment. The impingement of the shear layer on the opposite wall of the compartment gives rise to periodic vortex formation and highly organized oscillations in the shear layer. When a density interface is present inside the compartment, resonance conditions were set up when the oscillations of the internal standing waves were “locked in” with the shear layer oscillations. Under resonance conditions, internal standing waves with amplitudes of up to 0.1m were observed. The formation of the internal standing waves is linked to the shear layer oscillations. Resonance conditions result when the shear layer is oscillating close to the natural frequency of the stratified fluid system in the compartment. The results of this investigation are applicable for fresh water storage in floating bottom-opened tanks in the sea, where under resonance conditions, entrainment rates could be significantly increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until August 2007, Australia had not recorded an outbreak of equine influenza; indeed, significant quarantine precautions exist to safeguard against such an event. This article outlines the lead up to virus confirmation and the procedures to first test, then contain it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this research work we developed a new laboratory based transmission X-ray diffraction technique to perform in-situ deformation studies on a far more regular basis that is not possible at large scale synchrotron and neutron facilities. We studied the deformation mechanisms in light weight magnesium alloys during in-situ tensile testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sedation scales have the potential to facilitate effective procedural sedation and analgesia in the cardiac catheterization laboratory (CCL). For this potential to become realized, a scale that is suitable for use in the CCL either needs to be identified or developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim : To develop clinical practice guidelines for nurse-administered procedural sedation and analgesia in the cardiac catheterization laboratory.

Background : Numerous studies have reported that nurse-administered procedural sedation and analgesia is safe. However, the broad scope of existing guidelines for the administration and monitoring of patients who receive sedation during medical procedures without an anaesthetist present means there is a lack of specific guidance regarding optimal nursing practices for the unique circumstances where nurse-administered procedural sedation and analgesia is used in the cardiac catheterization laboratory.

Methods : A sequential mixed methods design was used. Initial recommendations were produced from three studies conducted by the authors: an integrative review; a qualitative study; and a cross-sectional survey. The recommendations were revised according to responses from a modified Delphi study. The first Delphi round was completed by nine senior cardiac catheterization laboratory nurses. All but one of the draft recommendations met the predetermined cut-off point for inclusion with 59 responses to the second round. Consensus was reached on all recommendations.

Implications for nursing : The guidelines that were derived from the Delphi study offer 24 recommendations within six domains of nursing practice: Pre-procedural assessment; Pre-procedural patient and family education; Pre-procedural patient comfort; Intra-procedural patient comfort; Intra-procedural patient assessment and monitoring; and Postprocedural patient assessment and monitoring.

Conclusion : These guidelines provide an important foundation towards the delivery of safe, consistent and evidence-based nursing care for the many patients who receive sedation in the cardiac catheterization laboratory setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There can be considerable overlap in the clinical presentation and laboratory features of dengue, malaria, and enteric fever, three important causes of fever in returned travelers. Routine laboratory tests including full blood examination (FBE), liver function tests (LFTs), and C-reactive protein (CRP) are frequently ordered on febrile patients, and may help differentiate between these possible diagnoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Massive, parallel sequencing is a potent tool for dissecting the regulation of biological processes by revealing the dynamics of the cellular RNA profile under different conditions. Similarly, massive, parallel sequencing can be used to reveal the complexity of viral quasispecies that are often found in the RNA virus infected host. However, the production of cDNA libraries for next-generation sequencing (NGS) necessitates the reverse transcription of RNA into cDNA and the amplification of the cDNA template using PCR, which may introduce artefact in the form of phantom nucleic acids species that can bias the composition and interpretation of original RNA profiles.