80 resultados para Power system simulation


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Wind energy is one of the most promising renewable energy sources due to its availability and climate-friendly attributes. Large-scale integration of wind energy sources creates potential technical challenges due to the intermittent nature that needs to be investigated and mitigated as part of developing a sustainable power system for the future. Therefore, this study developed simulation models to investigate the potential challenges, in particular voltage fluctuations, zone substation, and distribution transformer loading, power flow characteristics, and harmonic emissions with the integration of wind energy into both the high voltage (HV) and low voltage (LV) distribution network (DN). From model analysis, it has been clearly indicated that influences of these problems increase with the increased integration of wind energy into both the high voltage and low voltage distribution network, however, the level of adverse impacts is higher in the LV DN compared to the HV DN.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In utility power system, electricity demand is being covered largely by fossil fueled power generation, which contributes high level of GHG (greenhouse gas) emission and causes global warming worldwide. In order to reduce GHG emission level, most of the countries in the world targeting towards green energy that is power generation from RE (renewable energy) sources. In this paper, it is considered to study prospects of RE sources in particular, solar and wind in Victoria State which are abundant as compared to other sources of renewable. The wind and solar energy feasibility study and sensitivity analysis has been done for Victoria with the aid of HOMER (hybrid optimization model of electric renewable) simulation software. From the study, it has clearly evicted that wind energy combinational HPS (hybrid power system) has more contribution, and high potential than solar PV (photovoltaic) systems for a particular location. This study also investigates the influences of energy storage in the proposed HPS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The phenomenal growth in economy experienced in developed countries throughout the 20th century has largely been driven by the availability of conventional energy sources for electricity generation. However, increased concern about fossil fuels and adverse effect of carbon dioxide emission in to atmosphere changed the conventional power system to a viable one by integrating renewable energy sources into the existing system. Among the Renewable Energy (RE) sources, wind energy is one of the fastest growing technologies in reducing the Green House Gas (GHG) emissions in to the atmosphere due to its continuous availability throughout a period. Hence, this paper discusses the performance of a wind-grid connected system in a semi-arid region by conducting a case study. Wilson promontory, one of the best locations for wind generation in Victoria is considered as a case study. Hybrid Optimization Model for Electric Renewable (HOMER) is used as a simulating tool for this analysis. This study also presents the influences of storage system in the proposed Hybrid Power System (HPS) allowing energy to be stored during higher generations or lower load demands. In addition this paper also discusses the major integration issues to facilitate the large scale wind energy into the grid for reliable power generation and distribution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Today’s power system network has become more complex and it has more responsibilities and challenges to provide secure, reliable and quality energysupply to the communities. A small entity of electrical network known as Microgrid (MG) is more popular nowadays to enhance reliablity and secure level of energy supply, in case of any energy crisis in the utility network. The MG can also provide clean energy supply by integrating renewable energy sources effectively. TheMG with small scale solar photovoltaic (PV) power system is more suitable to provide reliable and clean energy supply for remote or urban communities in residential level. This paper presents the basic analysis study of stand-alone solar photovoltaic (PV) MG power system which has been developed with the aid of Matlab - Simulink software, on the basis of residential load profile and solar exposure level in a particular area of Geelong, Victoria State. The simulation result depicts the control behavior of MG power system with optimum sizing of PV (4.385 kW)and battery storage (480Ah/48V) facility, fulfills daily energy needs in residential load level. This study provides a good platform to develop an effective and reliable stand-alone MG power system for the remote communities in the near future.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Transient stability, an important issue to avoid the loss of synchronous operation in power systems, can be achieved through proper coordination and operation of protective devices within the critical clearing time (CCT). In view of this, the development of an intelligent decision support system is useful for providing better protection relay coordination. This paper presents an intelligent distributed agent-based scheme to enhance the transient stability of smart grids in light of CCT where a multi-agent framework (MAF) is developed and the agents are represented in such a way that they are equipped with protection relays (PRs). In addition to this, an algorithm is developed which assists the agents to make autonomous decision for controlling circuit breakers (CBs) independently. The proposed agents are responsible for the coordination of protection devices which is done through the precise detection and isolation of faults within the CCT. The agents also perform the duty of reclosing CBs after the clearance of faults. The performance of the proposed approach is demonstrated on a standard IEEE 39-bus test system by considering short-circuit faults at different locations under various load conditions. To further validate the suitability of the proposed scheme a benchmark 16-machine 68-bus power system is also considered. Simulation results show that MAF exhibits full flexibility to adapt the changes in system configurations and increase the stability margin for both test systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

n this paper, the design of a nonlinear excitation control of a synchronous generator is presented where the generator is connected to a single machine infinite bus (SMIB) system. An adaptive backstepping method is used to design the excitation controller with an objective of enhancing the overall dynamic stability of the SMIB system under different contingencies. In this paper, two types of contingencies are considered- i) unknown parameters and physical quantities during the controller design process and ii) controller performance evaluation under different system configurations such as three-phase short circuit faults. The adaption law, which is mainly based on the formulation of Lyapunov function, is used to estimate the unknown parameters which guarantee the convergence of different physical quantities of synchronous generators, e.g., the relative speed, terminal voltage, etc. The effectiveness of the proposed scheme is evaluated under different system configurations as mentioned in the second contingency and compared to that of an existing adaptive backstepping controller and a conventional power system stabilizer (PSS). Simulation results demonstrate the superiority of the proposed control scheme over the existing controllers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Electric vehicles (EVs) have recently gained much popularity as a green alternative to fossil-fuel cars and a feasible solution to reduce air pollution in big cities. The use of EVs can also be extended as a demand response tool to support high penetration of renewable energy (RE) sources in future smart grid. Based on the certainty equivalent adaptive control (CECA) principle and a customer participation program, this paper presents a novel control strategy using optimization technique to coordinate not only the charging but also the discharging of EV batteries to deal with the intermittency in RE production. In addition, customer charging requirements and schedules are incorporated into the optimization algorithm to ensure customer satisfaction, and further improve the control performance. The merits of this scheme are its simplicity, efficiency, robustness and readiness for practical applications. The effectiveness of the proposed control algorithm is demonstrated by computer simulations of a power system with high level of wind energy integration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a load frequency control scheme using electric vehicles (EVs) to help thermal turbine units to provide the stability fluctuated by load demands. First, a general framework for deriving a state-space model for general power system topologies is given. Then, a detailed model of a four-area power system incorporating a smart and renewable discharged EVs system is presented. The areas within the system are interconnected via a combination of alternating current/high voltage direct current links and thyristor controlled phase shifters. Based on some recent development on functional observers, novel distributed functional observers are designed, one at each local area, to implement any given global state feedback controller. The designed observers are of reduced order and dynamically decoupled from others in contrast to conventional centralized observer (CO)-based controllers. The proposed scheme can cope better against accidental failures than those CO-based controllers. Extensive simulations and comparisons are given to show the effectiveness of the proposed control scheme.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Green energy targets for coming decades advocates high penetration of wind energy in main energy matrix which also pose incendiary threat to stability and reliability of modern electric grid if their dynamic performance aspects are not assessed beforehand. Considering increasing interest in dynamic performance along with ancillary service assessment related to frequency regulation, development of suitable generic modeling has gained high priority. This paper presents modeling of type 4 full converter wind turbine generator system suitable for frequency regulation focusing on active power control. Complete model is a modification of WECC generic model with additional aerodynamic and pitch control model. Descriptions of individual sub models are presented and performance results are compared manufacturer specific GE type 4 WTG generic model by means of simulations in the MATLAB ® Power System Block set.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Over the past decade, the growing demand of Grid-connected photo voltaic (GCPV) system has been increasing due to an extensive use of renewable energy technologies for sustainable power generation and distribution. High-penetrated GCPV systems enhance the operation of the network by improving the voltage levels and reducing the active power losses along the length of the feeder. This paper aims to investigate the voltage variations and Total Harmonic Distortion (THD) of a typical GCPV system modelled in Power system simulator, PSS SINCAL with the change of level of PV integrations in a Low Voltage (LV) distribution network. Five different case studies are considered to investigate the impact of PV integrations on LV nodes and the corresponding voltage variations and harmonics. In addition, this paper also explores and benchmarks the voltage improvement techniques by implementing On Load Tap Changer (OLTC) with respective to the main transformer and addition of Shunt Capacitor (SC) at appropriate node points in LV network,

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Integration of solar PV and wind in to the distribution network is one of the most promising challenges of the modern power system networks to meet the growing demand of energy. Analysis of the effects of solar and wind intermittencies in the network are vital to maintain the power quality. Keeping this in view, this research paper focuses on impact analysis study of a typical power network with hybrid generation: solar PV and wind integration to quantify the level of impacts like power variation and voltage variation in the network through load flow analysis. Initially, a typical network model is developed using PSS-SINCAL and load profile analysis has been carried out based on the typical daily load profile and wind/solar profile to verify the power and voltage variations extensively in the network considering different scenarios. Results of this research analysis can be used as guidelines for utility grid to provide regulated and improved quality of energy supply by implementing appropriate planning of generation reserve and other control measures in the network

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Microgrid (MG) integrated with Distributed Generation (DG) provides several benefits like reliable, secure, and high efficient of energy supply, while minimizing power loss, deferring expansion of power distribution infrastructures, and reduced carbon emission of energy supply etc. to the communities. Despite of the several benefits, there are several challenges existing due to the integration of different characteristics and technology of DG sources in MG network. Power Quality (PQ) issue is one of the main technical challenges in MG power system. In order to provide improved PQ of energy supply, it is necessary to analyse and quantify the PQ level in MG network. This paper investigates the detail of PQ impacts in a real MG network carried out through an experimental analysis. Voltage and frequency variations/deviations are analysed in both on-grid and off-grid mode of MG operation at varying generation and varying load conditions. Similarly un-balance voltage and current level in neutral are estimated at unbalanced PV generation and uneven load distribution in MG network. Also current and voltage THD are estimated at different PV power level. Finally the results obtained from the analysis are compared to that of Australian network standard level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a new approach to design excitation controller for power systems to enhance small-signal stability. Partial feedback linearization scheme is used to design the controller for a linearized power system model which transforms a part of this model into a new system through linear coordinate transformation. In this paper, the excitation control law as a function of state variables is determined from the dynamics of the partly transformed new system provided that the controller stabilizes the remaining dynamics of the system which are not transformed through feedback linearization. The stability of the remaining dynamics is also discussed in this paper. Since the proposed control scheme uses state variables as feedback, it is analogous to a linear quadratic regulator (LQR) based excitation controller. Therefore, the performance of the proposed scheme is evaluated on a single machine infinite bus (SMIB) system and compared to that of an LQR controller.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Wind energy system integration can lead to adverse effects on modern electric grid so it is imperative toassess their dynamic performance before actual plant startup. Transmission system operators all over theworld stress the need for a proper wind turbine generator model for dynamic performance as well asancillary service assessments. Due to the bulk power system assessment requirements, developmentof suitable generic modeling has gained high priority. Generic modeling of type 4 full converter wind turbinegenerator system for application in frequency ancillary service investigations under varying windspeed and varying reference power has been presented in this study. Prevalent generic model, manufacturerspecific proprietary generic model along with detailed wind turbine model with synchronous generatoris also provided to highlight various modelling framework difference. Descriptions of individualsub models of proposed generic model are presented in detail and performance results are comparedand validated with GE’s proprietary generic model and detailed WTG model by means of simulationsin the MATLAB Power System Block set.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents an improved stability criterion for load frequency control (LFC) of time-delay power systems including AC/HVDC transmission links and EVs. By employing a novel refined Jensen-based inequality, an improved stability condition is derived in terms of feasible linear matrix inequalities (LMIs) which allow us to compute the maximal upper bounds of time-delay ensuring stability of the LFC scheme equipped with an embedded controller. Cases studies here are implemented for LFC scheme of a two-area power system, which is interconnected by parallel (AC/HVDC) links, with embedded proportional integral (PI) controller for discharged EVs. The relationships between the parameters of PI controller, supplementary control of HVDC links and delay margins of the LFC scheme are also discussed. As a consequence of facts, the results of delay margins can be used as a guideline to tune PI controller and set-up parameters for HVDC control.