57 resultados para Photovoltaic Solar Energy


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 2100 m2 (GFA) two-storey rammed earth building was built on the Thurgoona campus of Charles Sturt University in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes a thermal model of one of the second-storey offices on the west-end of the building. The simulation software, TRNSYS, has been used to predict office temperatures and comparisons are made between these and measurements made over a typical week in summer. Reasonable agreement has been achieved under most conditions. The model has been used to investigate key building parameters and strategies, including night flushing, to improve the thermal comfort in the office.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Small-scale producers of dried products in rural areas of developing countries must often rely on sun drying to dry their crops, but this can be unreliable and produce an inferior product. There is therefore a need for simple and inexpensive combustion devices that can be fabricated and used locally. A wood burner has been constructed from a "200 litre" steel drum and has then been evaluated experimentally. The thermal efficiency of the burner was found to be 31% in two trials. An energy balance, calculated for three trials, was within + 16%. Approximately one third of the energy available in the wood was lost in the flue gases, either as sensible heat or unburned volatile gases. Excess combustion air through the burner was calculated and measured to be approximately 400% of the stoichiometric requirements. A significant amount of energy was required to heat the thermal mass surrounding the burner, indicating that a lightweight insulated structure would be more suitable in most circumstances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Integrating solar energy devices with building products is a rapidly growing market in the building industry. The aim is to make solar devices that integrate into a standard facade, window, roof tile, membrane roof or long run roof. These serve as weatherproofing for a building and also generate electrical and thermal energy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Heat transfer by natural convection in triangular enclosures is an area of significant importance in applications such as the design of greenhouses, attics and solar water heaters. However, given its significance to these areas it has not been widely examined. In this study, the natural convection heat transfer coefficients in an attic shaped enclosure were determined for Grashof Numbers over the range 107 to 109. It was found that the measured heat transfer coefficients could be predicted to within 5% by Ridouane and Campo’ (2005) equation (Eqn. 1) for natural convection in a triangular enclosure previously developed for Grashof Numbers in the range 105 to 106.

Nu=0.286*A-0.286*Gr1/4 (Eqn. 1)

As such, it is suggested that this equation may be suitable for predicting the natural convection heat transfer coefficients in full scale attic enclosures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Poly(terthiophene) is an electronically conducting polymer with potential applications in solar energy devices. In the present study a series of poly(terthiophene) (PTTh) films are chemically polymerized (CP) at various temperatures and compared with a novel method of vapour phase polymerization (VPP). Utilizing the thiophene trimer (terthiophene) as the starting material, polymerization is achieved with Fe(III) tosylate. The films are characterized by their Raman and absorption spectra, in addition to differential scanning calorimetry (DSC), optical microscopy, electrochemical impedance spectroscopy (EIS) and four-point probe surface conductivity measurements. From the spectroscopy studies, increased conjugation length of the polymer chains with decreasing temperature or vapour phase polymerization is evident. More surprisingly, DSC results indicate the order of the polymer chains is dramatically enhanced by vapour phase polymerization and the D.C. conductivity is an order of magnitude higher for VPP compared with traditional CP films. Additionally, the optical micrographs reveal a significantly different morphology than the films cast from solution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In many highly glazed buildings, the thermal comfort of the occupants will tend to be related to the incoming solar energy and the solar heat gain coefficient of the glazing. Many real buildings tend to be deep relative their height and therefore, areas close to the facade receive a much greater amount of the incoming energy than those farther from it. In turn, this imbalance leads to occupants near the facade experiencing a high dissatisfaction with their thermal environment (near-facade zone). This study experimentally examines the thermal environment of occupants near the facade of a glazed building wall. It presents results for Fangers’ predicted mean vote (PMV) and the predicted percentage dissatisfied (PPD) and explores some options for improving the thermal environment in this near-facade zone.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In many highly glazed buildings, the thermal comfort of the occupants will tend to be related to the incoming solar energy and the heat transfer behaviour of the glazing. In this study, several glazing systems were designed using the software tools VISION 3 (University of Waterloo 1992) and WINDOW-6 (Lawrence Berkeley National Laboratory 2011), with a view to improving thermal environment of occupants near the glazed wall of a commercial office. The systems were fabricated and experimentally tested to validate the software modelling results. Subsequently, the glazing systems were retro-fitted to the office and tested in situ for a summer month. Results of this testing, in the form of Fangers’ predicted mean vote (PMV) and the predicted percentage dissatisfied (PPD), are presented, and some options for improving the thermal environment in this near-façade zone are discussed.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador: