188 resultados para Lens Tuero, Jesús Angel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. Little is known about the contact lens prescribing habits of optometrists in North America. The purpose of this survey was to obtain data on the types of lenses and solutions prescribed by Canadian optometrists.

Methods. One thousand Canadian optometrists were surveyed annually over seven consecutive years (2000 to 2006; n = 7000) on their contact lens prescribing preferences. Each survey requested a range of information about the contact lenses prescribed to the first 10 patients after its receipt.

Results. Over this time period, 1008 (14.4%) of the surveys were returned, providing data on 9383 fits. During the seven-year period, the ratio of male:female fits was 1:2 (3123:6217, 43 not reported), with a mean age of 31.3 ± 13.6 years (range 2 to 82 years). The ratio of new fits to refits was 2:3 (3780:5518, 85 not reported), with 91.3% of all fits being soft contact lenses (SCL). Of the SCL fits, 59.5% were spherical, 28.5% toric, 9.7% multifocal, and 2.3% cosmetic tints. Gas permeable (GP) fits were 46.6% spherical, 18.6% toric, 19.5% multifocal, and 6.6% were for orthokeratology (OK). Over the seven-year period, SCL prescribed for continuous wear (CW) increased from 3.2% to 14.3% between 2000 and 2004 and reduced to 8.1% in 2006, for all fits. The use of mid-water content (MWC) materials decreased from 34.6% to 2.7% and the use of silicone hydrogel (SH) lenses increased from 61.4% to 96.2%, for all CW fits. GP lens continuous wear increased from 0.7% to 30.6% of all GP lens fits by 2006. Daily wear (DW) of SH lenses decreased from 49.6% (2000) to 33.7% (2004) and then increased to 86.1% in 2006, for SH fits. MWC SCL fit on a monthly planned replacement (PR) basis reduced in popularity over the seven-year period (75.0% to 39.9%) and in 2006 more patients were fit overall with SH lenses (42.9%). The use of non-PR SCL declined from 20.5% to 4.5% of all fits. Fitting of low-water content lenses also declined (15.1% to 7.0%). High-water content (5.4% to10.2%) and SH lenses (5.4% to 42.9%) both increased. By 2006, the majority of GP lenses fit were with high Dk (HDK) materials (50.3%).

Conclusions. The preferred contact lens modality for Canadian optometrists appears to be DW SCL, which are replaced monthly. The proportion of lenses used for CW peaked in 2004, with SH SCL being the preferred material. The market share for GP lenses remains relatively unchanged, with an increasing proportion used for OK and CW. The launch of DW SH lenses in 2004 resulted in a marked increase in their reported fits, with a similar effect following the launch of a HDK GP lens material for CW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. The Menifocal Z is an alternating vision, concentric, bifocal gas-permeable (GP) contact lens; center distance is connected to near periphery by a smooth transition zone. The lens is produced using tisilfocon A (Menicon Z material), which is approved for up to 30 days of continuous wear (CW). The aim of this study was to evaluate the clinical performance of the Menifocal Z when worn for up to 30 days of CW for 6 months.

Methods. Thirty-five existing GP lens wearers were enrolled in the study. Subjects were fitted with Menifocal Z lenses and follow-up visits were conducted after 2 weeks of daily wear and 1 day, 1 week, 6 weeks, 3 and 6 months of CW. A range of objective and subjective clinical performance measures were assessed, including distance and near visual acuity, the physiological response to CW, and subjective evaluation of vision and comfort.

Results. Twenty-seven subjects (77%) completed the study and eight (23%) discontinued: five (14%) as a result of lens-related problems (four vision, one comfort) and three (9%) as a result of non-lens related reasons. Average CW time achieved by the subjects was 22 ± 2 days. Mean binocular logarithm of the minimum angle of resolution (logMAR) acuities at 6 months were: high contrast distance 0.03 (20/20-), low contrast distance 0.63 (20/80-), and high contrast near 0.26 (20/25, N4). Adverse responses and lens binding were minimal, and there were no significant increases in corneal staining, corneal vascularization, or superior palpebral conjunctival papillae over time (p > 0.05). Problems with night vision (distance and near) with the lenses were the most common difficulties reported by the subjects.

Conclusions. The Menifocal Z appears to be a promising option for presbyopic vision correction, providing successful correction of distance and near vision in a group of experienced GP lens wearers. The hyper Dk tisilfocon A (Menicon Z) material allowed for safe wear of the lenses on a CW basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The article deals with a study that examined the performance of a new silicone hydrogel multifocal contact lens for emerging presbyopes compared to other forms of correction. Study participants were asked to wear a different lens design for a week at a time. They were divided into the asymptomatic group and the symptomatic group. Results of the study showed that 24 participants had no difficulties with near vision tasks. It also found similar ghosting between the multifocal and habitual corrections for the near tasks under low illumination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limited Singapore research indicated a lack of exposure of modelling tasks at primary levels. Teacher reflection is used as a tool in design research cycles exploring the potentials of modelling tasks in a Singapore primary five classroom. Findings reveal that the teacher identified three potentials of a modelling task on children’s mathematisation process: the task provided a platform for children to (a) identify variables and form relationships between them, (b) relate school-based math learning to real-world experiences, and (c) justify their mathematical models. Implications on the promotion of modelling tasks at primary schools as well as teacher education are drawn.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The annual survey to collect data on the contact lens prescribing preferences of practitioners has continued for 12 years in Canada. Practitioners were surveyed for information on the first 10 patients they fitted with contact lenses immediately after receipt of said survey. A total of 121 completed surveys were returned, detailing contact lens fittings for 1,184 patients.

Of the patients fitted with contact lenses, the results indicated that the majority were prescribed soft lenses. The preferred modality was monthly planned replacement and over 67 per cent of the soft lens fits were made of silicone hydrogel materials. Of the rigid lens fits, the majority were prescribed for daily wear, as the overnight use of rigid lenses appears to be mainly for orthokeratology. Practitioners are recommending multipurpose solutions for the majority of their soft lens patients (85.6%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess current recommendations by optometrists for replacement frequency (RF) of silicone hydrogels (SH) and daily disposable (DD) contact lenses in Canada, determine rates of non-compliance with recommendations by both the optometrist and patient, and investigate reasons for non-compliance.

Methods: Survey packages were sent to optometrists in Canada who had agreed to participate. Patients completed survey questions regarding demographics and contact lens wearing patterns, including recommended and actual contact lens RF. Optometrists were asked to provide lens information and their recommendation for RF. Fifty-eight optometrists returned 654 surveys, of which 578 were eligible for analysis.

Results: Seventy percent of patients were female with a median age of 32 years. Lens type distribution was 18% DD, 35% two-week SH, and 47% one-month SH. Six percent were worn for extended wear. Daily wear median wearing time was 12 hours/day, a median of five days/week for DD, seven days/week for SH (two-week and one-month). Optometrists’ recommendations were non-compliant with the manufacturers’ recommended RF for 6% of DD, 35% of two week, and 2% of one-month patients. Patients were non-compliant with recommendations from both the manufacturer and optometrist for 12% of DD, 43% of two-week, and 31% of one-month lens wearers. The most common reason for non-compliance was forgetting which day to replace lenses. Fifty-six percent thought a reminder system would help with compliance. A higher proportion of compliant patients followed the RF because of confidence in their optometrist.

Conclusions: Optometrists generally recommended RFs consistent with manufacturers’ recommendations for DD and one-month SH lenses but often recommended longer intervals for two-week SH lenses. Patients were most compliant when wearing DD lenses and least compliant when wearing two-week SH lenses. Communication between the patient and optometrists concerning the risks of non-compliance, or initiating a reminder system might improve compliance.

Relevância:

20.00% 20.00%

Publicador: