82 resultados para CORROSION-RESISTANCE


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Novel Mg–Zr–Sr alloys have recently been developed for use as biodegradable implant materials. The Mg–Zr–Sr alloys were prepared by diluting Mg–Zr and Mg–Sr master alloys with pure Mg. The impact of Zr and Sr on the mechanical and biological properties has been thoroughly examined. The microstructures and mechanical properties of the alloys were characterized using optical microscopy, X-ray diffraction and compressive tests. The corrosion resistance was evaluated by electrochemical analysis and hydrogen evolution measurement. The in vitro biocompatibility was assessed using osteoblast-like SaOS2 cells and MTS and haemolysis tests. In vivo bone formation and biodegradability were studied in a rabbit model. The results indicated that both Zr and Sr are excellent candidates for Mg alloying elements in manufacturing biodegradable Mg alloy implants. Zr addition refined the grain size, improved the ductility, smoothed the grain boundaries and enhanced the corrosion resistance of Mg alloys. Sr addition led to an increase in compressive strength, better in vitro biocompatibility, and significantly higher bone formation in vivo. This study demonstrated that Mg–xZr–ySr alloys with x and y ⩽5 wt.% would make excellent biodegradable implant materials for load-bearing applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CrN films on a bipolar plate in polymer electrolyte membrane fuel cells have several advantages owing to their excellent corrosion resistance and mechanical properties. Three CrN samples deposited at various radio frequency (RF) powers by RF magnetron sputtering were evaluated under potentiodynamic, potentiostatic and electrochemical impedance spectroscopy conditions. The electrochemical impedance spectroscopy data were monitored for 168 h in a corrosive environment at 70 °C to determine the coating performance at +600 mVSCE under simulated cathodic conditions in a polymer electrolyte membrane fuel cell. The electrochemical behavior of the coatings increased with decreasing RF power. CrN films on the AISI 316 stainless steel substrate showed high protective efficiency and charge transfer resistance, i.e. increasing corrosion resistance with decreasing RF power. X-ray diffraction confirmed the formation of a CrN(200) preferred orientation at low RF power.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nonuniform electrodeposition is a major concern in almost every practical electrodeposition application. The ablility to control nonuniformity in electrodeposition is the key to successful plating for corrosion resistance, and more especially to meeting the very exacting requirements of electroforming, electrodeposition. This paper presents a novel technique namely the wire beam electrode (WBE) for characterizing and monitoring nonuniform electroplating processes. For the first time, the nonuniform distribution of electroplating currents (NDEC) has been mapped. Preliminary experimental results indicated that electrochemical heterogeneity was the key factor affecting NDEC. The secondary current distribution, rather than the primary current distribution, played a major role in determining the NDEC. This work suggests that the WBE is a practical tool for characterizing and optimizing electrodeposition processes and for verifying the accuracy and completeness of mathematic modelling of electrodeposition processes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AA5083 aluminium alloy has been shown to be partially passivated by a 2-step anodic pre-treatment in Trihexyl(tetradecyl)phosphonium bis(trifluoromethylsulfonyl)amide ([P6,6,6,14][NTf2]) ionic liquid. Surface characterisation revealed that an electrochemical etching process had occurred, comparable to acid etching of aluminium. Scanning electron microscopy/energy dispersive x-ray spectroscopy results have established that magnesium dealloyed from the Mg2Si intermetallic particles and metal fluorides were deposited onto the remaining Mg2Si sites, which subsequently led to decreased anodic corrosion kinetics (to one third of the control) as well as an increase in the corrosion and pitting potentials. This unique electrochemical etching process offers a simple and quick method to improve the corrosion resistance of an aluminium alloy as it leads to a more uniform surface, in terms of defect size and distribution, compared to conventional acid etching. This process has the potential to be used as a pre-treatment to inhibit corrosion of AA5083 alloy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nanostructured bainitic steels, containing bainitic ferrite laths and retained austenite films, formed at two different isothermal temperatures were compared  for corrosion behavior in chloride-containing solution using electrochemical techniques. The potentiodynamic polarization results suggest that nanostructured bainite formed at 200 °C exhibits marginally higher corrosion resistance compared with that at 350 °C. Post-corrosion analysis of the galvanostatically polarized samples revealed localized corrosion for both the steels, but the degree of attack was higher in the 350 °C steel than in the 200 °C steel. The localized corrosion attack was due to selective dissolution of the retained austenite phase. The higher volume fraction and larger size of retained austenite in the 350 °C steel as compared to that of the 200 °C steel contributed to the pronounced corrosion attack in the 350 °C steel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The characterization of novel metal reinforced electro-dialysis ion exchange membranes, for water desalination, by attenuated total reflectance Fourier transform infrared spectroscopy mapping is presented in this paper. The surface of the porous stainless steel fibre meshes was treated in order to enhance the amount of surface oxide groups and increase the material hydrophilicity. Then, the metal membranes were functionalized through a sol-gel reaction with silane coupling agents to enhance the affinity with the ion exchange resins and avoid premature metal oxidation due to redox reactions at the metal-polymer interface. Polished cross sections of the composite membranes embedded into an epoxy resin revealed interfaces between metallic frameworks and the silane layer at the interface with the ion exchange material. The morphology of the metal-polymer interface was investigated with scanning electron microscopy and Fourier transform infrared micro-spectroscopy. Fourier transform infrared mapping of the interfaces was performed using the attenuated total reflectance mode on the polished cross-sections at the Australian Synchrotron. The nature of the interface between the metal framework and the ion exchange resin was shown to be homogeneous and the coating thickness was found to be around 1 μm determined by Fourier transform infrared micro-spectroscopy mapping. The impact of the coating on the properties of the membranes and their potential for water desalination by electro-dialysis are also discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Titanium and its alloys are excellent candidates for biomedical implant. However, they exhibit relatively poor tribological properties. In this study, a two-step treatment including surface mechanical attrition treatment (SMAT) combined with thermal oxidation process has been developed to improve the tribological properties and biocompatibility of Ti. Ti after two-step treatment shows excellent wear-resistance and biocompatibility among all Ti samples, which can be ascribed to the highest surface energy, well crystallinity of rutile layer on its surface. Overall, the two-step treatment is a prospective method to produce excellent biomedical Ti materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Titanium alloy (Ti-6Al-4V) has a wide range of application in various fields of engineering. Titanium is mainly used to manufacture aerospace components like landing gear, fuselage, wings, engines etc. and biomedical components like hip joint, knee joint, dental implants etc. Titanium has outstanding material properties such as corrosion resistance, fatigue strength, tensile strength and a very good biocompatibility which makes this material very alluring for biomedical applications. Contrary, the machinability of the material is problematic because of the phase transformations and thus, titanium alloy is a challenge for machining operation. This research is a comparative analysis between the implants manufactured by traditional method of casting and machining. The femoral stem of the hip joint replacement is designed and the component is machined using a five-axis CNC machine.The machined component was subjected to surface roughness testing, tensile testing and bulk hardness testing. The values were compared with the values of titanium implants manufactured by casting. © (2014) Trans Tech Publications, Switzerland.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

 Novel Mg-Zr-Sr and Mg-1Zr-2Sr-xDy/yHo alloys have recently been developed for use as biodegradable implant materials. These alloys are recommended to be promising biodegradable implant materials as they have enhanced corrosion resistance and excellent biocompatibility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Duplex stainless steels (DSSs) have many advantages due to the unique structural combination of ferrite and austenite grains. The structural change of these materials is very complex during welding, and it deteriorates the functional properties. This research investigates different welding processes such as laser beam, resistance, tungsten inert gas, friction stir, submerged arc, and plasma arc weldings considering the research available in the literature. The welding mechanism, change of material structure, and control parameters have been analyzed for every welding process. This analysis clearly shows that DSS melts in all most all welding processes, but the thermal cycle and maximum heat input are different. This difference affects the resulting structure and functional properties of the weld significantly.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Whilst ionic liquids (IL) have been shown to inhibit corrosion on some reactive metals and alloys by forming a surface film, e.g. Li and Mg, understanding of the interaction between ionic liquids and aluminium is lacking. This research study investigated the viability of film formation on AA5083 Aluminium Alloy by electrochemical treatments in the trihexyl(tetradecyl)phosphonium diphenylphosphate ([P6,6,6,14][dpp]) IL. Two-step anodic treatments were performed on AA5083 in the IL, followed by a comparison of the corrosion behaviour of the IL-treated samples with that of a control. It has been revealed that the two-step IL-treatment led to reduced current densities on AA5083 under cyclic voltammetry scan in the IL before and after the IL-treatment. Lower corrosion rates have been shown on all samples treated in IL at room temperature. Surface characterisation showed a non-uniform porous film on the 50°C IL-treated sample with a film thickness ranging between 37nm and 155nm. The IL-film enhanced the corrosion resistance of AA5083 by protecting the Al-matrix and Fe-rich intermetallic particles (IMPs). Although findings of this study suggest similar IL-film formation as that on Li and Mg, more research needs to be conducted to optimise the electrochemical treatment conditions and ultimately to develop a robust IL-film formation procedure for corrosion protection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ti and Ti-based alloys have unique properties such as high strength, low density and excellent corrosion resistance. These properties are essential for the manufacture of lightweight and high strength components for biomedical applications. In this paper, Ti properties such as metallurgy, mechanical properties, surface modification, corrosion resistance, biocompatibility and osseointegration in biomedical applications have been discussed. This paper also analyses the advantages and disadvantages of various Ti manufacturing processes for biomedical applications such as casting, powder metallurgy, cold and hot working, machining, laser engineering net shaping (LEN), superplastic forming, forging and ring rolling. The contributions of this research are twofold, firstly scrutinizing the behaviour of Ti and Ti-based alloys in-vivo and in-vitro experiments in biomedical applications to determine the factors leading to failure, and secondly strategies to achieve desired properties essential to improving the quality of patient outcomes after receiving surgical implants. Future research will be directed toward manufacturing of Ti for medical applications by improving the production process, for example using optimal design approaches in additive manufacturing and investigating alloys containing other materials in order to obtain better medical and mechanical characteristics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stainless steel is the most widely used alloys of steel. The reputed variety of stainless steel having customised material properties as per the design requirements is Duplex Stainless Steel and Austenitic Stainless Steel. The Austenite Stainless Steel alloy has been developed further to be Super Austenitic Stainless Steel (SASS) by increasing the percentage of the alloying elements to form the half or more than the half of the material composition. SASS (Grade-AL-6XN) is an alloy steel containing high percentages of nickel (24%), molybdenum (6%) and chromium (21%). The chemical elements offer high degrees of corrosion resistance, toughness and stability in a large range of hostile environments like petroleum, marine and food processing industries. SASS is often used as a commercially viable substitute to high cost non-ferrous or non-metallic metals. The ability to machine steel effectively and efficiently is of utmost importance in the current competitive market. This paper is an attempt to evaluate the machinability of SASS which has been a classified material so far with very limited research conducted on it. Understanding the machinability of this alloy would assist in the effective forming of this material by metal cutting. The novelty of research associated with this is paper is reasonable taking into consideration the unknowns involved in machining SASS. The experimental design consists of conducting eight milling trials at combination of two different feed rates, 0.1 and 0.15 mm/tooth; cutting speeds, 100 and 150 m/min; Depth of Cut (DoC), 2 and 3 mm and coolant on for all the trials. The cutting tool has two inserts and therefore has two cutting edges. The trial sample is mounted on a dynamometer (type 9257B) to measure the cutting forces during the trials. The cutting force data obtained is later analyzed using DynaWare supplied by Kistler. The machined sample is subjected to surface roughness (Ra) measurement using a 3D optical surface profilometer (Alicona Infinite Focus). A comprehensive metallography process consisting of mounting, polishing and etching was conducted on a before and after machined sample in order to make a comparative analysis of the microstructural changes due to machining. The microstructural images were capture using a digital microscope. The microhardness test were conducted on a Vickers scale (Hv) using a Vickers microhardness tester. Initial bulk hardness testing conducted on the material show that the alloy is having a hardness of 83.4 HRb. This study expects an increase in hardness mostly due to work hardening may be due to phase transformation. The results obtained from the cutting trials are analyzed in order to judge the machinability of the material. Some of the criteria used for machinability evaluation are cutting force analysis, surface texture analysis, metallographic analysis and microhardness analysis. The methodology followed in each aspect of the investigation is similar to and inspired by similar research conducted on other materials. However, the novelty of this research is the investigation of various aspects of machinability and drawing comparisons between each other while attempting to justify each result obtained to the microstructural changes observed which influence the behaviour of the alloy. Due to the limited scope of the paper, machinability criteria such as chip morphology, Metal Removal Rate (MRR) and tool wear are not included in this paper. All aspects are then compared and the optimum machining parameters are justified with a scope for future investigations