140 resultados para titanium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current orthopaedic biomaterials research mainly focuses on developing implants that could induce controlled, guided and rapid healing. In the present study, the surface morphologies of titanium (Ti) and niobium (Nb) metals were tailored to form nanoporous, nanoplate and nanofibrelike structures through adjustment of the temperature in the alkali treatment. The in vitro bioactivity of these structures was then evaluated by soaking in simulated body fluid (SBF). It was found that the morphology of the modified surface significantly influenced the apatite inducing ability. The Ti surface with a nanofiber-like structure showed better apatite inducing ability, than the nanoporous or nanoplate surface structures. A thick dense apatite layer formed on the Ti surface with nanofiberlike structure after 1 week soaking in SBF. It is expected that the anofibre-like surface could achieve good apatite formation in vivo and subsequently enhance osteoblast cell adhesion and bone formation in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous titanium with a porosity of 75% was fabricated by space-holder sintering through powder metallurgy. The effect of the alkali and heat treatment on the strength of the porous titanium was investigated. Results indicated that the alkali and heat treatment led to a significant decrease in the strength of the porous titanium, whichwas causedby the degradation due to corrosion of the struts of the porous titanium with a layer of the reaction products, grain pullout and micro-cracks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an Mg-based metallic glass/titanium interpenetrating phase composite in which constituent phases form a homogeneously interconnected network. The porous titanium constrains shear bands propagation thoroughly and promotes shear bands branching and intersection subsequently. The homogeneous phase distribution promotes regularly distributed local shear deformation and leads to a uniform deformation for the composites. Moreover, the interpenetrating phase structure introduces a mutual-reinforcement between metallic glass and titanium. Therefore, the composite exhibits excellent mechanical performance with compressive fracture strength of 1783 MPa and fracture strain of 31%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One dimensional titanium oxides (TiO2) nanorods and nanowires have substantial applications in photocatalytic, nanoelectronic, and photoelectrochemical areas. These applications require large quantities of materials and a production technique suitable for future industry fabrication. We demonstrate here a new method for mass production of TiO2 nanorods from mineral ilmenite sands (FeTiO3). In this process, powder mixtures of ilmenite and activated carbon were first ball milled; the milled samples were then heated twice at two different temperatures. First high-temperature annealing produced metastable titanium oxide phases, and subsequent second low-temperature annealing in N2-5%H2 activates the growth of rutile nanorods. This solid-state growth process allows large-quantity production of rutile nanorods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite electrolytes of the lithium-ion-conducting ceramic Li1.3Al0.3Ti1.7(PO4)3 and polyetherurethane/lithium triflate polymer electrolyte have been prepared. Microscopy has shown that adhesion between the ceramic and polymer phases is poor, with gaps up to 1 μm at the interface. When dry, the composites are no more conductive than the pure polymer electrolyte. Exposing the samples to the vapour of solvents such as DMF, acetonitrile or water produces a significant increase in conductivity, over and beyond simple plasticization of the polymer. Pretreating the ceramic with a compatibilizing agent improves adhesion at the interface with the polymer, but decreases overall conductivity in the case investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is commonly accepted that titanium and the titanium alloying elements of tantalum, niobium, zirconium, molybdenum, tin, and silicon are biocompatible. However, our research in the development of new titanium alloys for biomedical applications indicated that some titanium alloys containing molybdenum, niobium, and silicon produced by powder metallurgy show a certain degree of cytotoxicity. We hypothesized that the cytotoxicity is linked to the ion release from the metals. To prove this hypothesis, we assessed the cytotoxicity of titanium and titanium alloying elements in both forms of powder and bulk, using osteoblast-like SaOS2 cells. Results indicated that the metal powders of titanium, niobium, molybdenum, and silicon are cytotoxic, and the bulk metals of silicon and molybdenum also showed cytotoxicity. Meanwhile, we established that the safe ion concentrations (below which the ion concentration is non-toxic) are 8.5, 15.5, 172.0, and 37,000.0 μg/L for molybdenum, titanium, niobium, and silicon, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the study, both experimental work and numerical modeling are performed to investigate the pore size effects on the mechanical properties and deformation behaviours of titanium foams. Cylindrical titanium foam samples with different pore sizes are fabricated through powder metallurgy. Scanning electron microscope (SEM) is used to determine the pore size, pore distribution and the ratios of the length to width of pores. Compressive tests are carried out to determine the mechanical properties of the titanium foams with different pore sizes. Finally, finite element modeling is attempted to simulate the deformation behaviour and the mechanical properties of the titanium foams. Results indicate that titanium foams with different pore sizes have different geometrical characteristics, which lead to different deformation behaviours of cell walls during compression, resulting in different mechanical properties of titanium foams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commercial Ti with a multimodal grain structure was successfully produced using cryorolling, followed by low-temperature annealing. This multimodal grain structure Ti exhibited a combination of high yield strength (926 MPa), a uniform elongation of 11% and a failure elongation of 23%. The strength enhancement was mainly derived from the ultrafine equiaxed grains, while the improved ductility originated from the large fraction of high-angle grain boundaries and the multimodal grain structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study examines the influence of different contents and types of process control agent (PCA), i.e., stearic acid (SA) and ethylene-bis-stearamide (EBS), on the microstructural evolution and characteristics of Ti-16Sn-4Nb (wt pct) alloy powders and bulk samples. The characterization of the powders and bulk samples was carried out by using chemical analysis, optical microscopy, scanning electron microscopy (SEM) combined with energy-dispersive spectrometry (EDS), and X-ray diffractometry. Results indicated that the powder recovered from the ball milling containers increased with increasing amounts of SA and EBS. Furthermore, adding more SA or EBS to the powder mixture resulted in a considerably smaller particle size, with a flaky-shaped morphology for the given ball milling time. Also, a slightly higher effectiveness was found for EBS when compared to SA. Meanwhile, the addition of both SA and EBS led to a delay in the alloy formation during mechanical alloying (MA) and caused contamination of the material with mainly carbon (C) and oxygen (O). An optimum amount of 1 wt pct PCA led to a good balance between cold welding and fracturing, and thus favored the formation of the titanium alloy. The microstructural observation of the bulk alloy showed a homogeneous distribution of fine Nb-rich ß-phase colonies within the α-Ti matrix with the addition of PCA less than 1 wt pct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous Ti-50.5Ni shape memory alloys with different porosities were produced using a space-holder sintering method. A new Ni-free Ti-based shape memory alloy, Ti-18Nb-5Mo-5Sn, was developed for potential biomedical applications, and a novel one-step hydrothermal process was applied to produce hydroxyapatite coatings on the surface of Ti alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrogen diffusion and phase transformation in a titanium particle were studied based on thermodynamic calculation. The mechanisms of hydrogen diffusion in different phases (alpha-Ti, beta-Ti and TiHx) were analyzed. A mobility database was developed for titanium– hydrogen system based on the experimental works on hydrogen diffusion coefficient reported in literature and the fundamental of diffusion. To implement the calculation, a commercial software package for the simulation of diffusion-controlled phase transformation was used. The hydrogen diffusion process, hydrogen distribution, phase transformation and phase growth rate during hydrogenization of a titanium particle at temperatures of 560 K, 800K and 1000K were discussed. The thermodynamics and kinetics analysis provided quantitative insight into the diffusion process and improved the understanding of diffusion mechanism and phase transformation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evolution of adiabatic shear localization in commercial titanium subjected to heavy cold rolling was investigated. The evolution of the morphology, microhardness, local shear strain, and local temperature increments were systematically studied and estimated. A shear band with about 25m in width was formed and fine nanograins with a range of dimensions varying from 20 to 160nm and had a mean size of about 70nm were observed inside the centre of shear band after 83% cold-rolling. Microhardness test shows that hardness within the shear band is markedly higher than that of the surrounding matrix. The calculated shear strain and maximum temperature increase within the shear band are much higher than that of the overall deformed sample. The initiation of shear localization may depend on geometric perturbation instead of thermal ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of artificial organs and implants for replacement of injured and diseased hard tissues such as bones, teeth and joints is highly desired in orthopedic surgery. Orthopedic prostheses have shown an enormous success in restoring the function and offering high quality of life to millions of individuals each year. Therefore, it is pertinent for an engineer to set out new approaches to restore the normal function of impaired hard tissues.

Over the last few decades, a large number of metals and applied materials have been developed with significant improvement in various properties in a wide range of medical applications. However, the traditional metallic bone implants are dense and often suffer from the problems of adverse reaction, biomechanical mismatch and lack of adequate space for new bone tissue to grow into the implant. Scientific advancements have been made to fabricate porous scaffolds that mimic the architecture and mechanical properties of natural bone. The porous structure provides necessary framework for the bone cells to grow into the pores and integrate with host tissue, known as osteointegration. The appropriate mechanical properties, in particular, the low elastic modulus mimicking that of bone may minimize or eliminate the stress-shielding problem. Another important approach is to develop biocompatible and corrosion resistant metallic materials to diminish or avoid adverse body reaction. Although numerous types of materials can be involved in this fast developing field, some of them are more widely used in medical applications. Amongst them, titanium and some of its alloys provide many advantages such as excellent biocompatibility, high strength-to-weight ratio, lower elastic modulus, and superior corrosion resistance, required for dental and orthopedic implants. Alloying elements, i.e. Zr, Nb, Ta, Sn, Mo and Si, would lead to superior improvement in properties of titanium for biomedical applications.

New processes have recently been developed to synthesize biomimetic porous titanium scaffolds for bone replacement through powder metallurgy. In particular, the space holder sintering method is capable of adjusting the pore shape, the porosity, and the pore size distribution, notably within the range of 200 to 500 m as required for osteoconductive applications. The present chapter provides a review on the characteristics of porous metal scaffolds used as bone replacement as well as fabrication processes of porous titanium (Ti) scaffolds through a space holder sintering method. Finally, surface modification of the resultant porous Ti scaffolds through a biomimetic chemical technique is reviewed, in order to ensure that the surfaces of the scaffolds fulfill the requirements for biomedical applications.