51 resultados para hydraulic PTO


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many Asian countries, rapid industrialization and urbanization has led to an increased number of cars, making wastewater from gas stations an important issue of concern in urban environment. This wastewater is characterized by high concentration of oil-water emulsion, which cannot be effectively removed by a conventional gravity separator. An experimental investigation on the treatability of oily wastewater from gas stations using a membrane bioreactor (MBR) system revealed that MBR system could achieve good removal efficiency with stability against shock loading. Optimum operating conditions were found to be at a hydraulic retention time of 4 h and an oil-loading rate of 1.8 kg oil m^sup -3^.d^sup -1^. It was anticipated that adding powdered activated carbon (PAC) in the MBR could help to adsorb the oils. However, operating the MBR with only microbial flocs has an advantage over adding PAC particles into the MBR, since the former condition could provide a prolonged cycle of filtration with a relatively lesser increase in transmembrane pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present study was to assess the simultaneous removal of physiochemical parameters in moderate strength wastewater using a lab scale horizontal subsurface flow constructed wetland (HFCW) with natural zeolite as a substrate. In this study, high-density polyethylene tanks (0.36 m2) were planted with phragmites australis and scirpus maritimus and received 0.012 m3/d to 0.08 m3/d of synthetic wastewater corresponding to a HLR of 0.035 to 0.243 m/d and a COD loading rate of 0.0148 kg COD (m2.d)-1 to 0.026 kg COD (m2.d)-1. The HFCW was subjected to three hydraulic retention times (HRT) for 4, 3 and 2 days respectively. Averaged data reported coincided with the plant age (4 to 55 weeks) and covered the entire cold season and early part of the hot season. Based on the 55 weeks of operation, the HFCW unit with zeolite achieved significantly higher removal for COD (85 to 88%), TN (54 to 96%), NH4-N (50 to 99%) and TSS (91 to 96%) respectively at all HRT. This system was proved to be tolerant to high organic loadings and nutrients, suggesting these substrates as viable options for biological treatment of wastewater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two laboratory-scale membrane bioreactor systems were investigated to treat high saline wastewater containing 1,000 mg/L COD and 32 g/L NaCl, namely: the yeast membrane bioreactor (YMBR) and the bacterial membrane bioreactor (BMBR). COD removal of both processes was above 90% at a hydraulic retention time (HRT) of 5 hours (volumetric loading of 5 kg COD/m³.d), sludge retention time (SRT) of 50 days (the MLSS of above 14 g/L and the F/M of 0.4 d-1). Under these operating conditions, the YMBR could run at a ten-fold lower transmembrane pressure with significantly reduced membrane fouling rate compared to BMBR. This may be because of low production of adhesive extracellular polymers (ECP) and the secondary filtration layer formed from large yeast cells. ECP production of bacterial sludge was increased considerably at high salt concentrations (32 g/L and 45 g/L) and long SRTs. For the bacterial sludge, the increased salinity led to increase in ECP, whereas the ECP content of the yeast sludge was relatively small.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In July 2004 the Budj Bim National Heritage Landscape was inscribed onto the National Heritage List. The place accorded with the criterion of A. Events, Processes (in demonstrating a place of Indigenous-European colonization conflict), B. Rarity (in demonstrating the context, historical and philosophy of benevolence of Governments to Indigenous people), F. Creative or technical achievement (in demonstrating technical accomplishment in construction the system), and, I. Indigenous tradition (in demonstrating longevity and continuity of cultural practices). Such affords Budj Bim, that hosts a unique Indigenous water harvesting and aquaculture infrastructure system dating some 7,000-10,000 years within a country that the Gunditjmara have managed for some 20,000-50,000 years, national standing. Within the lands gazetted is a complex and multi-faceted system that would today be categorised as a major integrated landscape planning and catchment management scheme that includes demonstrable major site engineering, hydraulic engineering, and aquaculture and water management scientific evidence and process knowledge and application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Agricultural discharge of herbicides to the Great Barrier Reef (GBR) poses significant threat to the marine ecosystem. This study evaluates the performance of a hybrid treatment system consists of a membrane bioreactor (MBR), UV disinfection unit and a granular activated carbon (GAC) column in treating Ametryn which is one of the major herbicides in agricultural discharges. While the MBR alone removes only 40% of Ametryn at a hydraulic retention time of 7.8 hours, the hybrid system removed Ametryn to below detection levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment efficiency of a wetland system requires a balance between pollutant loading rate and hydraulic retention time (HRT), hydraulic loading rate (HLR) and the suitable substrate to be used. The aim of this study was to investigate the treatment efficiency of horizontal subsurface flow constructed wetland planted with phragmites australis and scirpus maritimus containing three different substrates to treat agricultural wastewater under short term operation. Alum sludge and zeolite were used as substrates and gravel was used as a control for a laboratory-scale horizontal flow constructed wetland (CW) units that were made of high-density Polyethylene. The units were operated under 2, 3 and 4 days of HRTs and at different HLR for each substrate. Each beds received 0.012 m3/d to 0.08 m3/d of synthetic wastewater corresponding to a HLR of 0.035 to 0.243 m/d and a COD loading rate of 0.0148 kg COD (m2.d)-1 to 0.026 kg COD (m2.d)-1. The relationships between the substrate, retention time and removal efficiency, especially of organic matter and nutrient removal were investigated. All units showed relatively stable removal for COD during the entire operational period. The COD removal for all units and HRT were in ranged from 67% to 93%. The zeolite unit achieved significantly higher removal of TN, NH4-N and TSS compared to alum sludge and gravel unit at all HRT. The unit with zeolite was highly effective in removing TN (54 to 96%), NH4-N (50 to 99%) and TSS (91 to 96%) respectively, at 2, 3 and 4 days of HRT. Meanwhile, alum sludge was highly effective in removing phosphate. The removal of phosphate from alum sludge unit was ranged from 94 to 97% for all HRT. Compared to gravel CW unit, zeolite and alum sludge CW were proved to be tolerant to high organic loadings and nutrients, suggesting these substrates as viable options for biological treatment of agricultural wastewater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two emergent macrophytes, Arundo donax and Phragmites australis, were established in experimental subsurface flow, gravel-based constructed wetlands (CWs) and challenged by untreated stormwater collected from the hard-pan and other surfaces of a dairy processing factory in south-west Victoria, Australia. The hydraulic loading rate was tested at two levels, sequentially, 3.75 and 7.5 cm day -1. Some of the monitored variables were removed more efficiently by the planted beds in comparison to unplanted CWs (biochemical oxygen demand (BOD), total nitrogen (TN) and total phosphorus (TP); p<0.007) but there was no significant difference between the A. donax and P. australis CWs in removal of BOD, suspended solids (SS) and TN (p>0.007) at 3.75 cm day -1 or SS and TN at 7.5 cm day -1. At 3.75 cm day -1, BOD, SS, TN and TP removal in the A. donax and P. australis CWs was 71%, 61%, 78% and 75% and 65%, 60%, 73% and 41%, respectively. Nutrient removal at 7.5 cm day -1 in the A. donax and P. australis beds was 87%, 91%, 84% and 71% and 96%, 94%, 87% and 55%, respectively. As expected, the A. donax CWs produced considerably more biomass (10±1.2 kg wet weight) than the P. australis CWs (2.7±1.2 kg wet weight). This equates to approximately 107 and 36 tonnes ha -1 year -1 biomass (dry weight) for A. donax and P. australis, respectively (assuming 250 days of growing season and singlecut harvest). The performance similarity of the A. donax- and P. australis-planted CWs indicates that either may be used in HSSF wetlands treating dairy factory stormwater, although the planting of A. donax provides additional opportunities for secondary income streams through utilisation of the biomass produced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Internal combustion engines release about 1/3 of the energy bound in the fuel as exhaust waste gas energy and another 1/3 energy is wasted through heat transfer into the ambient. On the other hand losses through friction are the third largest root cause for energy loss in internal combustion engines. During city driving frictional losses can be of the same size as the effective work, and during cold start these losses are even bigger. Therefore it is obvious to utilise wasted exhaust energy to warm up the engine oil directly. Frictional losses of any engine can be reduced during part load. Sensitivity analyses have been conducted for different concepts that utilise exhaust energy to reduce engine viscosity and friction. For a new system with an exhaust gas/oil heat exchanger the following benefits have been demonstrated:

• Fuel consumption reductions of over 7% measured as an average over 5 NEDC tests
compared to the standard system configuration.
• Significant reductions in exhaust emissions, mainly CO and NOx have been achieved
• Significantly higher oil temperatures during cold start indicate large potential to
reduce engine wear through reduced water condensation in the crankcase
• Fuel consumption reductions of further 3.3% to 4.6% compared to the 7% measured
over the NEDC test can be expected under real world customer usage conditions at
lower ambient temperatures.

Oil temperature measurements and analysis resulted in the idea of a novel system with further potential to reduce fuel consumption. This Oil Viscosity Energy Recovery System (OVER 7™) consists of 3 key features that add significant synergies if combined in a certain way: an oil warm up circuit/bypass, including oil pressure control and Exhaust Gas/Oil Heat Exchanger. The system separates the thermal inertias of the oil in the engine galleries and the oil pan, reduces hydraulic pumping losses, increases the heat transfer from the cylinder head to the oil, and utilises the exhaust heat to reduce oil friction.

The project demonstrated that sensitivity analysis is an important tool for the evaluation of different concepts. Especially for new concepts that include transient heat transfer such a qualitative approach in combination with accurate experiments and measurements can be faster and more efficient in leading to the desired improvements compared to time consuming detailed simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Agricultural discharge of herbicides to the Great Barrier Reef (GBR) poses significant threat to the marine ecosystem. This study evaluates the performance of a hybrid treatment system consists of a membrane bioreactor (MBR), UV disinfection unit and a granular activated carbon (GAC) column in treating ametryn which is one of the major herbicides in agricultural discharges. While the MBR alone removes only 40% of ametryn at a hydraulic retention time of 7.8 h, the hybrid system removed ametryn to below detection levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two emergent macrophytes, Arundo donax and Phragmites australis, were established in experimental horizontal subsurface flow (HSSF), gravel-based constructed wetlands (CWs) and challenged by treated dairy processing factory wastewater with a median electrical conductivity of 8.9 mS cm−1. The hydraulic loading rate was tested at 3.75 cm day−1. In general, the plants grew well during the 7-month study period, with no obvious signs of salt stress. The major water quality parameters monitored (biological oxygen demand (BOD), suspended solids (SS) and total nitrogen (TN) but not total phosphorus) were generally improved after the effluent had passed through the CWs. There was no significance different in removal efficiencies between the planted beds and unplanted gravel beds (p > 0.007), nor was there any significant difference in removal efficiencies between the A. donax and P. australis beds for most parameters. BOD, SS and TN removal in the A. donax and P. australis CWs was 69, 95 and 26 % and 62, 97 and 26 %, respectively. Bacterial removal was observed but only to levels that would allow reuse of the effluent for use on non-food crops under Victorian state regulations. As expected, the A. donax CWs produced considerably more biomass (37 ± 7.2 kg wet weight) than the P. australis CWs (11 ± 1.4 kg wet weight). This standing crop equates to approximately 179 and 68 tonnes ha−1 year−1 biomass (dry weight) for A. donax and P. australis, respectively (assuming a 250-day growing season and single-cut harvest). The performance similarity of the A. donax and P. australis planted CWs indicates that either may be used in HSSF wetlands treating dairy factory wastewater, although the planting of A. donax provides additional opportunities for secondary income streams through utilisation of the biomass produced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Slab–girder structures composed of steel girder and reinforced concrete slab are widely used in buildings and bridges in the world. Their advantages are largely based on the composite action through the shear connection between slab and girder. In order to assess the integrity of this kind of structures, numerous vibration-based damage identification methods have been proposed. In this study, a scaled composite slab–girder model was constructed in the laboratory. Some removable shear connectors were specially designed and fabricated to connect the girder and slab that were cast separately. Then, a two-stage experiment including both static and vibration tests was performed. In the first stage, vibration tests were conducted under different damage scenarios, where a certain number of shear connectors at certain locations were removed step by step. In the second stage, two sets of hydraulic loading equipment were used to apply four-point static loads in the test. The loads are increased gradually until concrete slab cracked. The loading histories as well as deflections at different points of the beam are recorded. Vibration test was carried out before and after concrete cracking. Experimental results show that the changes of mode shapes and relative displacement between slab and girder may be two promising parameters for damage identification of slab–girder structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dynamic Evolving Neural-Fuzzy Inference System (DENFIS) is a Takagi-Sugeno-type fuzzy inference system for online learning which can be applied for dynamic time series prediction. To the best of our knowledge, this is the first time that DENFIS has been used for rainfall-runoff (R-R) modeling. DENFIS model results were compared to the results obtained from the physically-based Storm Water Management Model (SWMM) and an Adaptive Network-based Fuzzy Inference System (ANFIS) which employs offline learning. Data from a small (5.6 km2) catchment in Singapore, comprising 11 separated storm events were analyzed. Rainfall was the only input used for the DENFIS and ANFIS models and the output was discharge at the present time. It is concluded that DENFIS results are better or at least comparable to SWMM, but similar to ANFIS. These results indicate a strong potential for DENFIS to be used in R-R modeling.