58 resultados para Power distribution


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Isolated distribution systems are dispersed throughout regional Queensland to supply small isolated communities that are distant from the main supply grid. The costs of maintaining the electricity supply to these areas is costly; mainly due to the cost of diesel fuel. Furthermore, there is a community focus on climate change, and Ergon Energy aims to reduce the reliance on fossil fuels whilst optimising cost efficiencies and greenhouse gas emissions. The objective of this study is to examine the impacts of renewable energy sources in isolated power systems. For the locations studied, viable renewable energy sources have been integrated into these networks. Anticipated challenges and issues with the integration of the intermittent renewable energy sources were addressed, using mitigation techniques, including energy storage solutions. The investigation and findings demonstrated that network improvements can be achieved by an ideal level of renewable penetration, which has been the main focus of the project. The project involved the development and simulation of MATLAB Simulink and SINCAL models of the two isolated networks at Gununa and Bamaga. The subsequent analysis of these systems has shown a modest penetration level of renewables can be combined with energy storage solutions, which reduces fuel consumption and greenhouse gas emissions at these locations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large-scale renewable energy (RE) integration into the distribution network (DN) causes uncertainties due to its intermittent nature and is a challenging task today. In general RE sources are mostly connected near the end user level, i.e., in the low voltage distribution network. RE integration introduces bi-directional power flows across distribution transformer (DT) and hence DN experiences with several potential problems that includes voltage fluctuations, reactive power compensation and poor power factor in the DN. This study identifies the potential effects causes due to large-scale integration of RE into the Berserker Street Feeder, Frenchville Substation under Rockhampton DN. From the model analyses, it has clearly evident that voltage of the Berserker Street Feeder fluctuates with the increased integration of RE and causes uncertainties in the feeder as well as the DN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wind energy is one of the most promising renewable energy sources due to its availability and climate-friendly attributes. Large-scale integration of wind energy sources creates potential technical challenges due to the intermittent nature that needs to be investigated and mitigated as part of developing a sustainable power system for the future. Therefore, this study developed simulation models to investigate the potential challenges, in particular voltage fluctuations, zone substation, and distribution transformer loading, power flow characteristics, and harmonic emissions with the integration of wind energy into both the high voltage (HV) and low voltage (LV) distribution network (DN). From model analysis, it has been clearly indicated that influences of these problems increase with the increased integration of wind energy into both the high voltage and low voltage distribution network, however, the level of adverse impacts is higher in the LV DN compared to the HV DN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes an effective VAR planning based on reactive power margin for the enhancement of dynamic voltage stability in distribution networks with distributed wind generation. The analysis is carried over a distribution test system representative of the Kumamoto area in Japan. The detailed mathematical modeling of the system is also presented. Firstly, this paper provides simulation results showing the effects of composite load on voltage dynamics in the distribution network through an accurate time-domain analysis. Then, a cost-effective combination of shunt capacitor bank and distribution static synchronous compensator (D-STATCOM) is selected to ensure fast voltage recovery after a sudden disturbance. The analysis shows that the proposed approach can reduce the size of compensating devices, which in turn, reduces the cost. It also reduces power loss of the system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates small-signal stability of a distribution system with distributed generator and induction motor load, as a dynamic element. The analysis is carried out over a distribution test system with different types of induction motor loads. The system is linearised by the perturbation method. Eigenvalues and participation factors are calculated to see the modal interaction of the system. The study indicates that load voltage dynamics significantly influence the damping of a newly identified voltage mode. This mode has frequency of oscillation between the electromechanical and subsynchronous oscillation of power systems. To justify the validity of the modal analysis time domain simulation is also carried out. Finally, significant parameters of the system that affect the damping and frequency of the oscillation are identified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents potential barriers to integrate the squirrel cage induction generator (SCIG) and doubly fed induction generator (DFIG) type wind turbine in distribution networks. The analysis is carried out over a 16 bus distribution test system. Both static and dynamic analyses are performed to see the impact of two different generators on the distribution system. The simulation results show that both SCIG and DFIG type wind turbines have significant impact on the static voltage stability, power loss, and dynamic behavior of the system, which should be taken into account to improve systems performance before integrating wind generation in existing distribution networks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, charging effect of dynamic Plug in Hybrid Electric Vehicle (PHEV) is presented in a renewable energy based electricity distribution system. For planning and designing a distribution system, PHEVs are one of the most important factor as it is going to be a spinning reserve of energy, and also a major load for distribution network. A dynamic load model of PHEVs is introduced here based on third order battery model. To determine the system adequacy, it is necessary to do a micro level analysis to know the PHEVs load impact on grid. Scope of such analysis will cover the performance of wind and solar generation with dynamic PHEVs load, as well as the stability analysis of the power grid to demonstrate that it is important to consider the dynamics of PHEVs load in a renewable energy based distribution network.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional distribution networks were not originally designed to accommodate power generation facilities. The installation of distributed generation (DG) units with significatn capacity in these passive networks can cause reverse power flows which will result in some conflicts with the operation of the existing protection system. In this context, utilities around the world have started establishing requirements to ensure safe and reliable interconnection of generators in low- and medium-voltage networks. Grid interconnection is presently one of the most important issues involving DG. This paper presents a critical review of the requirements adopted by distribution companies in selected countries such as the USA, the UK, germany and Australia to facilitate the connection of DG. Critical issues such as voltage regulation, islanding operation, dynamic interactions among DG and loads are discussed to identify a few points where attention is still needed to improve the reliability of distribution systems

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a decentralised controller design for doubly-fed induction generators (DFIGs) to enhance dynamic performance of distribution networks. The change in the output power due to the variable nature of wind is considered as an uncertain term in the design algorithm. In addition, the interconnection effect of the other subsystems are considered in the design process. The H norm of the uncertain system is found out and simultaneous output-feedback linear controllers are designed based controller is verified on a 16 bus distribution test system for severe disturbances. Simulation results indicate that the designed controller is robust against uncertainties in operating conditions

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maintaining reliability and stability of a power systems in transmission and distribution level becomes a big challenge in present scenario. Grid operators are always responsible to maintain equilibrium between available power generation and demand of end users. Maintaining grid balance is a bigger issue, in case of any unexpected generation shortage or grid disturbance or integration of any renewable energy sources like wind and solar power in the energy mix. In order to compensate such imbalance and to facilitate more renewable energy sources with the grid, energy storage system (ESS) started to be playing an important role with the advancement of the state of the art technology. ESS can also help to get reduction in greenhouse gas (GHG) emission by means of integrating more renewable energy sources to the grid. There are various types of Energy Storage (ES) technologies which are being used in power systems network from large scale (above 50MW) to small scale (up to 100KW). Based on the characteristics, each storage technology has their own merits and demerits. This paper carried out extensive review study and verifies merits and demerits of each storage technology and identifies the suitable technology for the future. This paper also has conducted feasibility study with the aid of E-SelectTM tool for various ES technologies in applications point of view at different grid locations. This review study helps to evaluate feasible ES technology for a particular electrical application and also helps to develop smart hybrid storage system for grid applications in efficient way.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The advancement in solar photovoltaic (PV) technology, the cost and efficiency of PVs have encouraged users worldwide to adopt more and more PVs as it is free from greenhouse gas emissions and unlimited in nature. Integration of roof-top solar PV systems is currently emerging rapidly in Australia as the governments are giving attractive incentives and encouraging households to build a sustainable climate-friendly society for the future. The key major barriers to the integration of roof-top solar PV systems are the uncertainties in the performance of the low voltage distribution network due to the intermittent nature of solar PV sources. In this paper, a model was developed to investigate the potential technical impacts of integrating roof-top solar PV systems into the low voltage distribution network in a subtropical climate. The results show that integration of roof-top solar PV in the customer premises causes uncertainties such as voltage fluctuations, phase unbalance, distribution transformer overloading, reactive power compensation, and harmonic injections that detract the overall power quality of the typical distribution network. © 2014 AIP Publishing LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increased concern about global warming coupled with the escalating demand of energy has driven the conventional power system to be more reliable one by integrating Renewable Energies (RE) in to grid. Over the recent years, integration of solar PV forming a gridconnected PV is considered as one of the most promisingtechnologies to the developed countries like Australia to meet the growing demand of energy. This rapid increase in grid connected photovoltaic (PV) systems has made the supply utilities concerned about the drastic effects that have to be considered on the distribution network in particular voltage fluctuations, harmonic distortions and the Power factor for sustainable power generation. However, irrespective of thefact that the utility grid can accommodate the variability of load or irregular solar irradiance, it is essential to study the impact of grid connected PV systems during higher penetration levels as the intermittent nature of solar PV adversely effects the grid characteristics in meeting the load demand. Hence, keeping this in track, this paper examines the grid-connected PV system considering a residential network of Geelong region (38◦.09' S and 144◦.21’ E) and explores the level of impacts considering summer load profile with a change in the level of integrations. Initially, a PV power system network model is developed in Matlab-Simulink environment and the simulations are carried out to explore the impacts of solar PV penetration at low voltage distribution network considering power quality (PQ) issues such as voltage fluctuations, harmonics distortion at different load conditions.