61 resultados para Potassium Fluoride


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of glutathione (GSH) and glutathione disulfide (GSSG) is a crucial tool to assess cellular redox state. Herein we report a direct approach to determine intracellular GSH based on a rapid chromatographic separation coupled with acidic potassium permanganate chemiluminescence detection, which was extended to GSSG by incorporating thiol blocking and disulfide bond reduction. Importantly, this simple procedure avoids derivatisation of GSH (thus minimising auto-oxidation) and overcomes problems encountered when deriving the concentration of GSSG from ‘total GSH’. The linear range and limit of detection for both analytes were 7.5 × 10−7 to 1 × 10−5 M, and 5 × 10−7 M, respectively. GSH and GSSG were determined in cultured muscle cells treated for 24 h with glucose oxidase (0, 15, 30, 100, 250 and 500 mU mL−1), which exposed them to a continuous source of reactive oxygen species (ROS). Both analyte concentrations were greater in myotubes treated with 100 or 250 mU mL−1 glucose oxidase (compared to untreated controls), but were significantly lower in myotubes treated with 500 mU mL−1 (p < 0.05), which was rationalised by considering measurements of H2O2 and cell viability. However, the GSH/GSSG ratio in myotubes treated with 100, 250 and 500 mU mL−1 glucose oxidase exhibited a dose-dependent decrease that reflected the increase in intracellular ROS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This sub-collection is the result of an investigation into the mechanism of organic fouling in membrane filtration processes. In this experiment, poly(vinylidene fluoride) (PVDF) membranes were used to filter two types of organic foulants, protein and yeast with a concentration of 50mg/l and 20 mg/l, respectively, from suspension in a dead-end filtration cell. These model foulants were stained with fluorescent dyes before filtration. This dataset contains a stack of images of the fouling layer on the PVDF membrane surface captured by a confocal laser scanning microscope (CLSM) and its associated acquisition software. This dataset would be useful to researchers who are investigating the membrane organic fouling mechanism so that new membrane materials and new anti-fouling surface treatment technologies can be developed for water and wastewater industry in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This collection is the result of an investigation into the backwashing efficiency of poly(vinylidene fluoride) (PVDF) membrane fouled by two types of organic foulants, protein and yeast. In this experiement, poly(vinylidene fluoride) (PVDF) membrane was used to filter those organic foulants from suspensions in a dead-end stirred cell. The organic foulants were stained with fluorescent dyes before filtration. After filtration, the PC membrane was backwashed. Consequently, a stack of images were captured from the fouling layers on the PVDF membrane surface using confocal laser scanning microscope (CLSM) and its associated image acquisition software. It contains image data of poly(vinylidene fluoride) (PVDF) membranes' fouling layer when two types of organic foulants (protein and yeast) present. By comparing with the same membrane without backwashing, the efficiency of backwashing was computed. This data collection would be useful to researchers who are evaluating the backwashing efficiency of PVDF membrane in order to optimize frequency and operational conditions of backwashing by membrane materials and by water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This collection is the result of an investigation into the backwashing efficiency of poly(vinylidene fluoride) (PVDF) membrane fouled by yeast and sodium alginate. In this experiement, poly(vinylidene fluoride) (PVDF) membrane was used to filter two types of organic foulants from suspensions in a dead-end stirred cell. The organic foulants including yeast and sodium alginate were stained with fluorescent dyes before filtration. After filtration, the PC membrane was backwashed. Consequently, a stack of images were captured from the fouling layers on the PVDF membrane surface using confocal laser scanning microscope (CLSM) and its associated image acquisition software. The data collection contains image data of poly(vinylidene fluoride) (PVDF) membranes' fouling layer when two types of organic foulants (yeast and sodium alginate) are present. By comparing with the same membrane without backwashing, the efficiency of backwashing was computed. The collection would be useful to researchers evaluating the backwashing efficiency of poly(vinylidene fluoride) (PVDF) membrane in order to optimize frequency and operational conditions of backwashing by membrane materials and by water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This sub-collection is the result of an investigation into the mechanism of organic fouling in membrane filtration processes. In this experiment, poly(vinylidene fluoride) (PVDF) membranes were used to filter two types of organic foulants, protein and sodium alginate with a concentration of 50mg/l and 40 mg/l, respectively, from suspension in a dead-end filtration cell. These model foulants were stained with fluorescent dyes before filtration. This dataset contains a stack of images of the fouling layer on the PVDF membrane surface captured by a confocal laser scanning microscope (CLSM) and its associated acquisition software. This dataset would be useful to researchers who are investigating the membrane organic fouling mechanism so that new membrane materials and new anti-fouling surface treatment technologies can be developed for water and wastewater industry in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This sub-collection is the result of an investigation into the mechanism of organic fouling in membrane filtration processes. In this experiment, poly(vinylidene fluoride) (PVDF) membranes were used to filter three types of organic foulants, yeast, protein and sodium alginate with a concentration of 50mg/l, 40mg/l and 20 mg/l, respectively, from suspension in a dead-end filtration cell. These model foulants were stained with fluorescent dyes before filtration. This dataset contains a stack of images of the fouling layer on the PVDF membrane surface captured by a confocal laser scanning microscope (CLSM) and its associated acquisition software. This dataset would be useful to researchers who are investigating the membrane organic fouling mechanism so that new membrane materials and new anti-fouling surface treatment technologies can be developed for water and wastewater industry in the future .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work was to improve the analytical usefulness of acidic potassium permanganate chemiluminescence for the determination of various analytical compounds. This thesis also examined the fundamental chemistry involved with these types of reactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Randomly oriented poly(vinylidene fluoride) (PVDF) nanofibre webs prepared by a needleless electrospinning technique were used as an active layer for making mechanical-to-electrical energy harvest devices. With increasing the applied voltage in the electrospinning process, a higher b crystal phase was formed in the resulting PVDF nanofibres, leading to enhanced mechanical-to-electrical energy conversion of the devices. The power generated by the nanofibre devices was able to drive a miniature Peltier cooler, which may be useful for the development of mechanically driven cooling textile. In addition, the needleless electrospinning also showed great potential in the production of nanofibres on a large scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exploring high performance cathode materials is essential to realize the adoption of Li-ion batteries for application in electric vehicles and hybrid electric vehicles. FeF3, as a typical iron-based fluoride, has been attracting considerable interest due to both the high electromotive force value of 2.7 V and the high theoretical capacity of 237 mA h g_1 (1e_ transfer). In this study, we report a facile lowtemperature solution phase approach for synthesis of uniform iron fluoride nanocrystals on reduced graphene sheets stably suspended in ethanol solution. The resulting hybrid of iron fluoride nanocrystals and graphene sheets showed high specific capacity and high rate performance for iron fluoride type cathode materials. High stable specific capacity of about 210 mA h g_1 at a current density of 0.2 C was achieved, which is much higher than that of LiFePO4 cathode material. Notably, these iron fluoride/ nanocomposite cathode materials demonstrated superior rate capability, with discharge capacities of 176, 145 and 113 mA h g_1 at 1, 2 and 5 C, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:
Rapid intradialytic potassium shifts during haemodialysis have been associated with increased mortality and morbidity. Standardising dialysate potassium to 2 mmol/l may decrease the potassium shift.

Objective:
To examine the effect of standardising dialysate potassium to 2 mmol/l for all chronic dialysis treatments.
Design:
Pre- and post-intervention comparison of monthly serum potassium.

Participants
:
Ninety-seven individuals, of whom 56 patients could be matched across both data collection periods.

Methods
:
Serum potassium data were categorised based on a target range 3.5–6.0 mmol/l. Overall pre- and postintervention mean scores were compared using a paired samples t-test. Data for patients routinely prescribed dialysate potassium 1 mmol/l pre-intervention (n ¼ 6) underwent paired samples t-test to compare their mean serum potassium pre and post-intervention.

Results
:
There was no statistically significant change in serum potassium post- intervention. The majority of patients remained within the target range, including the subset of patients who had a history of high serum potassium during the pre- intervention period.

Conclusions
:
A standard potassium dialysate of 2 mmol/l may reduce intradialytic serum potassium shifts and may assist in standardising safer work practices.