68 resultados para Naming speed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Film thinning experiments have been conducted with aqueous films between two air phases in a thin film pressure balance. The films are free of added surfactant but simple NaCl electrolyte is added in some experiments. Initially the experiments begin with a comparatively large volume of water in a cylindrical capillary tube a few millimeters in diameter, and by withdrawing water from the center of the tube the two bounding menisci are drawn together at a prescribed rate. Thismodels two air bubbles approaching at a controlled speed. In pure water, the results show three regimes of behavior depending on the approach speed; at slow speed (<1 μm/s) it is possible to form a flat film of pure water, ∼100 nm thick, that is stabilized indefinitely by disjoining pressure due to repulsive double-layer interactions between naturally charged air/water interfaces. The data are consistent with a surface potential of -57mV on the bubble surfaces. At intermediate approach speed (∼1-150 μm/s), the films are transiently stable due to hydrodynamic drainage effects, and bubble coalescence is delayed by ∼10-100 s. At approach speeds greater than ∼150 μm/s, the hydrodynamic resistance appears to become negligible, and the bubbles coalesce without any measurable delay. Explanations for these observations are presented that take into account Derjaguin-Landau-Verwey-Overbeek and Marangoni effects entering through disjoining pressure, surface mobility, and hydrodynamic flow regimes in thin film drainage. In particular, it is argued that the dramatic reduction in hydrodynamic resistance is a transition from viscosity-controlled drainage to inertia-controlled drainage associated with a change from immobile to mobile air/water interfaces on increasing the speed of approach of two bubbles. A simple model is developed that accounts for the boundaries between different film stability or coalescence regimes. Predictions of the model are consistent with the data, and the effects of adding electrolyte can be explained. In particular, addition of electrolyte at high concentration inhibits the near-instantaneous coalescence phenomenon, thereby contributing to increased foam film stability at high approach speeds, as reported in previous literature. This work highlights the significance of bubble approach speed as well as electrolyte concentration in affecting bubble coalescence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In statistical classification work, one method of speeding up the process is to use only a small percentage of the total parameter set available. In this paper, we apply this technique both to the classification of malware and the identification of malware from a set combined with cleanware. In order to demonstrate the usefulness of our method, we use the same sets of malware and cleanware as in an earlier paper. Using the statistical technique Information Gain (IG), we reduce the set of features used in the experiment from 7,605 to just over 1,000. The best accuracy obtained in the former paper using 7,605 features is 97.3% for malware versus cleanware detection and 97.4% for malware family classification; on the reduced feature set, we obtain a (best) accuracy of 94.6% on the malware versus cleanware test and 94.5% on the malware classification test. An interesting feature of the new tests presented here is the reduction in false negative rates by a factor of about 1/3 when compared with the results of the earlier paper. In addition, the speed with which our tests run is reduced by a factor of approximately 3/5 from the times posted for the original paper. The small loss in accuracy and improved false negative rate along with significant improvement in speed indicate that feature reduction should be further pursued as a tool to prevent algorithms from becoming intractable due to too much data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel sensitive humidity nanosensor based on Na1-doped ZnO nanofiber membrane has been prepared via electrospinning and calcination. The product was characterized by scanning electron microscopy and X-ray diffraction. During the whole relative humidity (11%–95%) measurement, the response and recovery time is about 3 and 6 s, respectively, with good linearity, and reproducibility. These remarkable and sensitive sensing performances make our product a good candidate in fabricating humidity sensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose : This study was conducted to devise a new individual calibration method to enhance MTI accelerometer estimation of free-living level walking speed.

Method : Five female and five male middle-aged adults walked 400 m at 3.5, 4.5, and 5.5 km·h-1, and 800 m at 6.5 km·h-1 on an outdoor track, following a continuous protocol. Lap speed was controlled by a global positioning system (GPS) monitor. MTI counts-to-speed calibration equations were derived for each trial, for each subject for four such trials with each of four MTI, for each subject for the average MTI, and for the pooled data. Standard errors of the estimate (SEE) with and without individual calibration were compared. To assess accuracy of prediction of free-living walking speed, subjects also completed a self-paced, "brisk" 3-km walk wearing one of the four MTI, and differences between actual and predicted walking speed with and without individual calibration were examined.

Results : Correlations between MTI counts and walking speed were 0.90 without individual calibration, 0.98 with individual calibration for the average MTI, and 0.99 with individual calibration for a specific MTI. The SEE (mean ± SD) was 0.58 ± 0.30 km·h-1 without individual calibration, 0.19 ± 0.09 km·h-1 with individual calibration for the average MTI monitor, and 0.16 ± 0.08 km·h-1 with individual calibration for a specific MTI monitor. The difference between actual and predicted walking speed on the "brisk" 3-km walk was 0.06 ± 0.25 km·h-1 using individual calibration and 0.28 ± 0.63 km·h-1 without individual calibration (for specific accelerometers).

Conclusion : MTI accuracy in predicting walking speed without individual calibration might be sufficient for population-based studies but not for intervention trials. This individual calibration method will substantially increase precision of walking speed predicted from MTI counts.