36 resultados para Magnetic Resonance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A poly(2-acrylamido-2-methyl-1-propane-sulphonate) (PAMPS) ionomer containing both sodium and quaternary ammonium cations functionalised with an ether group, has been characterised in terms of its thermal properties, ionic conductivity and sodium ion dynamics. The ether oxygen was incorporated to reduce the Na+ association with the anionic sulfonate groups tethered to the polymer backbone, thereby promoting ion dissociation and ultimately enhancing the ionic conductivity. This functionalised ammonium cation led to a significant reduction in the ionomer Tg compared to an analogue system without an ether group, resulting in an increase in ionic conductivity of approximately four orders of magnitude. The sodium ion dynamics were probed by 23Na solid-state NMR, which allowed the signals from the dissociated (mobile) and bound Na+ cations to be distinguished. This demonstrates the utility of 23Na solid-state NMR as a probe of sodium dynamics in ionomer systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Muscle size in the lower limb is commonly assessed in neuromuscular research as it correlates with muscle function and some approaches have been assessed for their ability to provide valid estimates of muscle volume. Work to date has not examined the ability of different measurement approaches (such as cross-sectional area (CSA) measures on magnetic resonance (MR) imaging) to accurately track changes in muscle volume as a result of an intervention, such as exercise, injury or disuse. Here we assess whether (a) the percentage change in muscle CSA in 17 lower-limb muscles during 56 days bed-rest, as assessed by five different algorithms, lies within 0.5% of the muscle volume change and (b) the variability of the outcome measure is comparable to that of muscle volume. We find that an approach selecting the MR image with the highest muscle CSA and then a series of CSA measures, the number of which depended upon the muscle considered, immediately distal and proximal, provided an acceptable estimate of the muscle volume change. In the vastii, peroneal, sartorius and anterior tibial muscle groups, accurate results can be attained by increasing the spacing between CSA measures, thus reducing the total number of MR images and hence the measurement time. In the two heads of biceps femoris, semimembranosus and gracilis, it is not possible to reduce the number of CSA measures and the entire muscle volume must be evaluated. Using these approaches one can reduce the number of CSA measures required to estimate changes in muscle volume by ~60%. These findings help to attain more efficient means to track muscle volume changes in interventional studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we examine the reliability and validity (in comparison to magnetic resonance imaging; MRI) of real-time ultrasound measures of lumbar erector spinae thickness. We also consider the between-day reliability of the lumbar multifidus muscle area as measured via ultrasound. 23 male subjects aged 21-45 years were measured three times over the course of nine days by one operator. The first (L1) through to the fifth (L5) lumbar vertebral levels were measured on the left and right sides. MRI was performed on the same day as first ultrasound scanning. For between-day intra-rater reliability, intra-class correlation co-efficients (ICCs), standard error of the measurement, minimal detectable difference and co-efficients of variation (CVs) were calculated along with their 95% confidence intervals and Bland-Altman analysis was performed. On Bland-Altman analysis, erector spinae thickness and multifidus area ultrasound measures 'agreed' with equivalent MR measures, though the correlation between MR and ultrasound measures was typically poor to moderate. For both ultrasound measures, the ICCs ranged from 'moderate' to 'excellent' at individual vertebral levels, although multifidus area (CV ranged from 8 to 15%) was less reliable than erector spinae thickness (CV ranged from 6 to 10%). 'Agreement' on Bland-Altmann analysis was present between days for all ultrasound measures. Averaging between sides and between vertebral levels improved reliability. Average erector spinae thickness showed a CV of 5.5% (ICC 0.77) and average multifidus area 6.2% (ICC 0.80).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 This project focuses on the development of zinc doped ferrite nanoparticle based MRI contrast agents with enhanced contrast and site-specific targeting for atherosclerosis diagnosis. The engineered nanocomplexes developed were validated through MRI scans using rat models with potential for multimodal imaging and effective therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic Resonance Imaging (MRI) is a widely used technique for acquiring images of human organs/tissues. Due to its complex imaging process, it consumes a lot of time to produce a high quality image. Compressive Sensing (CS) has been used by researchers for rapid MRI. It uses a global sparsity constraint with variable density random sampling and L1 minimisation. This work intends to speed up the imaging process by exploiting the non-uniform sparsity in the MR images. Locally Sparsified CS suggests that the image can be even better sparsified by applying local sparsity constraints. The image produced by local CS can further reduce the sample set. This paper establishes the basis for a methodology to exploit non-uniform nature of sparsity and to make the MRI process time efficient by using local sparsity constraints.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this research was to assess the functional brain activity and perceptual rating of innocuous somatic pressure stimulation before and after exercise rehabilitation in patients with chronic pain.

Materials and methods: Eleven chronic pain patients and eight healthy pain-free controls completed 12 weeks of supervised aerobic exercise intervention. Perceptual rating of standardized somatic pressure stimulation (2 kg) on the right anterior mid-thigh and brain responses during functional magnetic resonance imaging (fMRI) were assessed at pre- and postexercise rehabilitation.

Results: There was a significant difference in the perceptual rating of innocuous somatic pressure stimulation between the chronic pain and control groups (P=0.02) but no difference following exercise rehabilitation. Whole brain voxel-wise analysis with correction for multiple comparisons revealed trends for differences in fMRI responses between the chronic pain and control groups in the superior temporal gyrus (chronic pain > control, corrected P=0.30), thalamus, and caudate (control > chronic, corrected P=0.23). Repeated measures of the regions of interest (5 mm radius) for blood oxygen level-dependent signal response revealed trend differences for superior temporal gyrus (P=0.06), thalamus (P=0.04), and caudate (P=0.21). Group-by-time interactions revealed trend differences in the caudate (P=0.10) and superior temporal gyrus (P=0.29).

Conclusion: Augmented perceptual and brain responses to innocuous somatic pressure stimulation were shown in the chronic pain group compared to the control group; however, 12-weeks of exercise rehabilitation did not significantly attenuate these responses.