95 resultados para High Pressure Liquid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resin acids are reported to be of major toxicological importance in pulp mill effluents for Rainbow Trout. Their determination, using a high performance liquid chromatographic method, is described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, an activity based screening technique combining two-dimensional liquid chromatography (2DHPLC) with UV-absorbance and chemiluminescence detection was applied to study “Ristretto”, "Decaffeinatto” and “Volluto” espresso coffees. This technique, which coupled the separation power of 2DHPLC with the sensitivity and selectivity of the chemiluminescence detection, offers great potential for screening complex samples for antioxidant compounds. Detailed information regarding the complexity of the sample, and the variation between these three coffees could be obtained using this multidimensional-hyphenated method of analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

HPLC with acidic potassium permanganate chemiluminescence detection was employed to analyse 17 Cabernet Sauvignon wines across a range of vintages (1971–2003). Partial least squares regression analysis and principal components analysis was used in order to investigate the relationship between wine composition and vintage. Tartaric acid, vanillic acid, catechin, sinapic acid, ethyl gallate, myricetin, procyanadin B and resveratrol were found to be important components in terms of differences between the vintages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An improved post-column 2,2´-diphenyl-1-picrylhydrazyl (DPPH•) radical scavenging assay for the screening of antioxidants in complex matrices was developed. Experimental parameters believed to be influential to DPPH• response were studied in a univariate approach. Optimum conditions were found to be: 5×10−5M DPPH• reagent prepared in a 75% methanol: 25% 40mM citric acid–sodium citrate buffer (pH 6) solution, degassed with nitrogen; reaction coil of 2m×0.25mm i.d. PEEK tubing; detection at 521 nm; analysis at room temperature. The analytical utility of this protocol was evaluated by screening for antioxidants in thyme and green tea, in comparison with two commonly employed methodologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The antioxidant profiles of various espresso coffees were established using HPLC with UV-absorbance detection and two rapid, simultaneous, on-line chemical assays that enabled the relative reactivity of sample components to be screened. The assays were based on (i) the colour change associated with reduction of the 2,2´-diphenyl-1-picrylhydrazyl radical (DPPH•); and (ii) the emission of light (chemiluminescence) upon reaction with acidic potassium permanganate. Results from the two approaches were similar and reflected the complex array of antioxidant species present in the samples. However, some differences in selectivity were observed. Chromatograms generated with the chemiluminescence assay contained more peaks, which was ascribed to the greater sensitivity of the reagent towards minor, readily oxidisable sample components. The three coffee samples produced closely related profiles, signifying their fundamentally similar chemical compositions and origin. Nevertheless, the overall intensity and complexity of the samples in both UV absorption and antioxidant assay chromatograms were aligned with the manufacturers description of flavour intensity and character.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement of glutathione (GSH) and glutathione disulfide (GSSG) is a crucial tool to assess cellular redox state. Herein we report a direct approach to determine intracellular GSH based on a rapid chromatographic separation coupled with acidic potassium permanganate chemiluminescence detection, which was extended to GSSG by incorporating thiol blocking and disulfide bond reduction. Importantly, this simple procedure avoids derivatisation of GSH (thus minimising auto-oxidation) and overcomes problems encountered when deriving the concentration of GSSG from ‘total GSH’. The linear range and limit of detection for both analytes were 7.5 × 10−7 to 1 × 10−5 M, and 5 × 10−7 M, respectively. GSH and GSSG were determined in cultured muscle cells treated for 24 h with glucose oxidase (0, 15, 30, 100, 250 and 500 mU mL−1), which exposed them to a continuous source of reactive oxygen species (ROS). Both analyte concentrations were greater in myotubes treated with 100 or 250 mU mL−1 glucose oxidase (compared to untreated controls), but were significantly lower in myotubes treated with 500 mU mL−1 (p < 0.05), which was rationalised by considering measurements of H2O2 and cell viability. However, the GSH/GSSG ratio in myotubes treated with 100, 250 and 500 mU mL−1 glucose oxidase exhibited a dose-dependent decrease that reflected the increase in intracellular ROS.