59 resultados para CORNEAL


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diabetic neuropathy is a significant clinical problem that currently has no effective therapy, and in advanced cases, leads to foot ulceration and lower limb amputation. The accurate detection, characterization and quantification of this condition are important in order to define at-risk patients, anticipate deterioration, monitor progression, and assess new therapies. This review evaluates novel corneal methods of assessing diabetic neuropathy. Two new noninvasive corneal markers have emerged, and in cross-sectional studies have demonstrated their ability to stratify the severity of this disease. Corneal confocal microscopy allows quantification of corneal nerve parameters and noncontact corneal esthesiometry, the functional correlate of corneal structure, assesses the sensitivity of the cornea. Both these techniques are quick to perform, produce little or no discomfort for the patient, and are suitable for clinical settings. Each has advantages and disadvantages over traditional techniques for assessing diabetic neuropathy. Application of these new corneal markers for longitudinal evaluation of diabetic neuropathy has the potential to reduce dependence on more invasive, costly, and time-consuming assessments, such as skin biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare live and photographic (still) grades of corneal staining of the same eyes and the repeatability of grading between two investigators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim : To determine the internalization and protective effects of potential ophthalmic formulations and nanoformulated natural proteins in ex-vivo bovine corneal alkali burn model.

Methods : The bovine cornea obtained were subjected to the 0.5 N NaOH insult that induced alkali burn and inflammation as observed in the in vivo situation. The toxic effects of the nanoformulation were evaluated in the normal and insult induced cornea using histological analysis. Internalization studies were carried out using in vivo imaging and analysis (IVIS, PerkinElmer, USA).

Results : The nanoformulations employed in this study showed no obvious changes in the integrity of the cornea. Further, improvements in the light transmittance and reduced inflammation were observed. The IVIS showed a dose dependant increase in the uptake of the nanoformulations with time.

Conclusion : The nanoformulated bovine lactoferrin and SurR9-C84A (SR9) proteins evaluated in the ex vivo bovine corneal irritation model is the first of its kind, and we report here the non-toxic and therapeutic potential of these formulations for topical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the first corneal transplant in 1905, improved surgical techniques and the development of immunosuppressive drugs have led to excellent success rates for organ and tissue transplantation procedures. This Chapter ,"'ill focus on the cadaveric donation of tissue and the attitudes towards it of health professionals, because they are key players in the donation- transplantation process.

The chapter begins with an overview of cadaveric tissue donation, including what can currently be transplanted. It will then present what is known about health professionals' attitudes to and knowledge of tissue donation and the impact that these have on donation rates. Attitudes, their components and their effect upon behaviour are explored using theories arising from social psychology to explain how these influence actual or intended behaviours associated with the discussion of donation wishes with relatives of the potential donor. Since some tissues, such as blood and bone marrow, can only normally be donated during life, these will be excluded since the behaviours associated with blood donation differ significantly from those associated with cadaveric tissue donation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This prospective study was designed to subjectively and objectively evaluate the performance of an aspheric multifocal back surface rigid gas permeable (RGP) contact lens. The multifocal element of this lens design consisted of an aspheric optical zone that varied according to the patient's ametropia, corneal topography, and required reading addition.

Methods: We fit 28 presbyopic subjects with an aspheric multifocal back surface RGP contact lens (age range: 45 to 68 years). Reading additions ranged from +0.75 D to +2.50 D. Subjects were assessed initially and at 2, 6, and 12 weeks for ocular changes, visual performance, and subjective responses.

Results: We required 116 RGP lenses to achieve an acceptable fit and visual acuity in 28 subjects (55 eyes). At the final visit, the distance logMAR acuity with the multifocal contact lens (+0.12 +/-0.10) was not statistically different (t=-0.623, P= 0.5388) from spectacle acuity at the initial visit (+0.10 +/-0.12). The near logMAR acuity with the multifocal contact lens at the final visit (0.36 +/- 0.12) was not statistically different from that for near acuity with spectacles at the initial visit (0.33 +/- 0.13). No slit lamp signs worsened during the study. A reduction in myopia of 0.67 D was noted by the final visit. Spectacle blur was noted if the acuity at the initial refraction was compared to the acuity with the same refraction at the final visit (t= -3.287, P= 0.0028) but not when the refractive changes were incorporated (t= 1.058, P= 0.3127). All subjects rated the performance of the lenses very highly: comfort, 86%; distance acuity, 83%; near acuity, 73%; and stability of vision, 74%. Twenty-four subjects (86%) chose the multifocal contact lens as their preference.

Conclusion: We demonstrated that a multifocal design is able to provide acceptable distance and near correction for presbyopic patients. The aspheric geometry required can be optimized for a given patient by considering his/her degree of ametropia, as well as the corneal topography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose:  The purpose of the study was to obtain anterior segment biometry for 40 normal eyes and to measure variables that may be useful to design large diameter gas permeable contact lenses that sit outside the region normally viewed by corneal topographers. Also, the distribution of these variables in the normal eye and how well they correlated to each other were determined.

Methods:  This is a cross-sectional study, in which data were collected at a single study visit. Corneal topography and imaging of the anterior segment of the eye were performed using the Orbscan II and Visante OCT. The variables that were collected were horizontal K reading, central corneal/scleral sagittal depth at 15 mm chord, and nasal and temporal angles at the 15 mm chord using the built-in software measurement tools.

Results:  The central horizontal K readings for the 40 eyes were 43 ± 1.73 D (7.85 ± 0.31 mm), with ± 95% confidence interval (CI) of 38.7 (8.7 mm) and 46.6 D (7.24 mm). The mean corneal/scleral sagittal depth at the 15 mm chord was 3.74 ± 0.19 mm and the range was 3.14 to 4.04 mm. The average nasal angle (which was not different from the temporal angle) at the 15 mm chord was 39.32 ± 3.07 degrees and the ± 95%CI was 33.7 and 45.5 degrees. The correlation coefficient comparing the K reading and the corneal/scleral sagittal depth showed the best correlation (0.58, p < 0.001). The corneal/scleral sagittal depth at 15 mm correlated less with the nasal angle (0.44, p = 0.004) and the weakest correlation was for the nasal angle at 15 mm with the horizontal readings (0.32, p = 0.046).

Conclusion:  The Visante OCT is a valuable tool for imaging the anterior segment of the eye. The Visante OCT is especially effective in providing the biometry of the peripheral cornea and sclera and may help in fitting GP lenses with a higher percentage of initial lens success, when the corneal sag and lens sag are better matched.