59 resultados para Acidulated phosphate fluoride


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High molecular weight hyaluronic acid (HA) is present in articular joints and synovial fluid at high concentrations; yet despite numerous studies, the role of HA in joint lubrication is still not clear. Free HA in solution does not appear to be a good lubricant, being negatively charged and therefore repelled from most biological, including cartilage, surfaces. Recent enzymatic experiments suggested that mechanically or physically (rather than chemically) trapped HA could function as an “adaptive” or “emergency” boundary lubricant to eliminate wear damage in shearing cartilage surfaces. In this work, HA was chemically grafted to a layer of self-assembled amino-propyl-triethoxy-silane (APTES) on mica and then cross-linked. The boundary lubrication behavior of APTES and of chemically grafted and cross-linked HA in both electrolyte and lipid 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) solutions was tested with a surface forces apparatus (SFA). Despite the high coefficient of friction (COF) of μ ≈ 0.50, the chemically grafted HA gel significantly improved the lubrication behavior of HA, particularly the wear resistance, in comparison to free HA. Adding more DOPC lipid to the solution did not improve the lubrication of the chemically grafted and cross-linked HA layer. Damage of the underlying mica surface became visible at higher loads (pressure >2 MPa) after prolonged sliding times. It has generally been assumed that damage caused by or during sliding, also known as “abrasive friction”, which is the main biomedical/clinical/morphological manifestation of arthritis, is due to a high friction force and, therefore, a large COF, and that to prevent surface damage or wear (abrasion) one should therefore aim to reduce the COF, which has been the traditional focus of basic research in biolubrication, particularly in cartilage and joint lubrication. Here we combine our results with previous ones on grafted and cross-linked HA on lipid bilayers, and lubricin-mediated lubrication, and conclude that for cartilage surfaces, a high COF can be associated with good wear protection, while a low COF can have poor wear resistance. Both of these properties depend on how the lubricating molecules are attached to and organized at the surfaces, as well as the structure and mechanical, viscoelastic, elastic, and physical properties of the surfaces, but the two phenomena are not directly or simply related. We also conclude that to provide both the low COF and good wear protection of joints under physiological conditions, some or all of the four major components of joints—HA, lubricin, lipids, and the cartilage fibrils—must act synergistically in ways (physisorbed, chemisorbed, grafted and/or cross-linked) that are still to be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Phosphate binder medication adherence is required to maintain optimal phosphate levels and minimise bone disease in people with end stage kidney disease.

Objectives To examine the impact of a nurse-led education intervention on bone disorder markers, adherence to phosphate binder medication and medication knowledge.

Design Descriptive study with a paired pre–post intervention survey.

Participants Adults receiving haemodialysis.

Methods Twelve-week intervention where patients self-administered their phosphate binder medication at each dialysis treatment. Nurses provided individualised education. Patients completed a pre- and post-intervention survey designed to explore their knowledge of phosphate binders.

Results There were no statistically significant changes in clinical markers but a significant improvement in the proportion of patients who took their phosphate binder correctly, increasing from 44 to 72% (p = 0.016). There were moderate to large effect size changes for improved knowledge.

Conclusions A nurse-led intervention education programme can increase patients' phosphate binder adherence. However, this does not necessarily manifest into improved serum phosphate levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To develop polymeric-ceramic nanocarriers (NCs) in order to achieve oral delivery of the anticancer neutraceutical iron-saturated bovine lactoferrin (Fe-bLf) protein.

Materials & methods: Fe-bLf or paclitaxel (Taxol®) were adsorbed onto calcium phosphate nanocores, enclosed in biodegradable polymers chitosan and alginate. The Fe-bLf or Taxol-loaded NCs indicated as AEC–CP–Fe-bLf or AEC–CP–Taxol NCs, respectively, were made by combination of ionic gelation and nanoprecipitation. Size distribution, morphology, internalization and release profiles of the NCs were studied along with evaluation of in vitro and in vivo anticancer activities and compared with paclitaxel.

Results: AEC–CP–Fe-bLf NCs obtained spherical morphology and showed enhanced endocytosis, transcytosis and anticancer activity in Caco-2 cells in vitro. AEC–CP–Fe-bLf NCs were supplemented in an AIN 93G diet and fed to mice in both prevention and treatment human xenograft colon cancer models. AEC–CP–Fe-bLf NCs were found to be highly significantly effective when given orally, as a pretreatment, 1 week before Caco-2 cell injections. None of the mice from the AEC–CP–Fe-bLf NC-fed group developed tumors or showed any signs of toxicity, while the mice fed the control AIN 93G diet showed normal tumor growth. Fe-bLf or Taxol, when given orally in a diet as nanoformulations post-tumor development, showed a significant regression in the tumor size with complete inhibition of tumor growth later, while intratumoral injection of Taxol just delayed the growth of tumors. The pharmacokinetic and bioavailability studies indicated that nanoformulated Fe-bLf was predominantly present on tumor cells compared to non-nanoformulated Fe-bLf. Fe-bLf-loaded NCs were found to help in absorption of iron and thus may have utility in enhancing the iron uptake during iron deficiency without interfering with the absorption of calcium.

Conclusion: With the promising results of our study, the future potential of NC-loaded Fe-bLf in chemoprevention and in the treatment of human colon cancer, deserves further investigation for translational research and preclinical studies of other malignancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Randomly oriented poly(vinylidene fluoride) (PVDF) nanofibre webs prepared by a needleless electrospinning technique were used as an active layer for making mechanical-to-electrical energy harvest devices. With increasing the applied voltage in the electrospinning process, a higher b crystal phase was formed in the resulting PVDF nanofibres, leading to enhanced mechanical-to-electrical energy conversion of the devices. The power generated by the nanofibre devices was able to drive a miniature Peltier cooler, which may be useful for the development of mechanically driven cooling textile. In addition, the needleless electrospinning also showed great potential in the production of nanofibres on a large scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exploring high performance cathode materials is essential to realize the adoption of Li-ion batteries for application in electric vehicles and hybrid electric vehicles. FeF3, as a typical iron-based fluoride, has been attracting considerable interest due to both the high electromotive force value of 2.7 V and the high theoretical capacity of 237 mA h g_1 (1e_ transfer). In this study, we report a facile lowtemperature solution phase approach for synthesis of uniform iron fluoride nanocrystals on reduced graphene sheets stably suspended in ethanol solution. The resulting hybrid of iron fluoride nanocrystals and graphene sheets showed high specific capacity and high rate performance for iron fluoride type cathode materials. High stable specific capacity of about 210 mA h g_1 at a current density of 0.2 C was achieved, which is much higher than that of LiFePO4 cathode material. Notably, these iron fluoride/ nanocomposite cathode materials demonstrated superior rate capability, with discharge capacities of 176, 145 and 113 mA h g_1 at 1, 2 and 5 C, respectively.