88 resultados para optometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

.Background: Some universities are looking to provide a more diverse range of clinical learning experiences through extended clinical placement programs. This approach will potentially have a significant impact on practitioners. The aim of this study was to conduct a national survey of optometrists to ascertain their perspectives on participating in extended clinical placement programs. Methods: Members of Optometry Australia were invited to participate in a survey conducted during June and July 2014. Results: A total of 268 practitioners participated (six per cent of registered Australian optometrists): 159 were predominantly employees or locums and 109 were owners or managers who identified as the key representative of a practice or organisation for the purpose of this survey. Almost two-thirds (65 per cent) of participants, who were employees or locums were supportive of extended clinical placement programs. Among this group, females were more likely to be supportive than males (p=0.033). In comparison, just over one-third (34 per cent) of participants who were key decision-makers were supportive, with 30 per cent possibly supportive and 36 per cent not supportive. Among key decision-makers, males were more likely to be supportive (p=0.009). The top three perceived advantages of supervising a student were: opportunity to mentor early career development, opportunity to give back to the profession and future recruitment. The top three perceived disadvantages were: burden on time, decrease in number of patients examined and burden on support staff. Suggested incentives for supervising students were credit for continuing professional development and financial remuneration. Conclusion: There appears to be moderate support for extended clinical placement programs; however, there are incentives that might engage a larger proportion of the profession in the future. These findings can inform the development of effective and sustainable clinical training programs for optometry students. Additionally, the findings might be used as evidence to seek Government support for clinical placement training in optometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. This non-dispensing cross-over study was conducted to determine if lenses presoaked in Opti-Free RepleniSH (OFR) or ReNu MultiPlus (RMP) cause solution-induced corneal staining (SICS) and subsequent cell sloughing before the typical 2 h in vivo examination point.

Methods. Study lenses (PureVision) were worn bilaterally by 13 participants for periods of 15, 30, 60, and 120 min using two different contralateral care regimen pairings. The lens worn on the test eye was soaked overnight in either OFR or RMP and the control eye in Clear Care (CC). After lens removal, corneal staining was rated on a scale of 0 (negligible) to 100 (severe) for four peripheral quadrants and the central region, and the differential global staining score was calculated by subtracting baseline staining scores. Following the staining assessment, corneal cells were collected from the ocular surface using a non-contact irrigation system to determine ocular cell shedding rates.

Results. Differential global staining score with OFR was greater than CC with the differences being statistically significant at 30 and 60 min (p < 0.01). Maximum staining with RMP was significantly greater than OFR and peaked after 60 and 120 min of lens wear (p < 0.01). On average, 710 ± 470 ocular cells were collected after lens wear, with similar shedding seen independent of solution or lens wear duration (p > 0.05).

Conclusions. SICS occurred earlier but to a significantly lower degree when PureVision lenses were presoaked in OFR compared with RMP, while lenses presoaked in CC did not cause SICS. Ocular surface cell shedding after lens removal was not impacted by lens wear durations of <=2 h.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. Corneal vasculature change in contact lens wearers has been linked to the level of hypoxia within the cornea. To assess the impact a treatment has on limbal vessels, a sensitive method of measurement and quantification is required.

Methods. A group of 21 highly myopic, hydrogel wearers, with preexisting signs of corneal hypoxia, were enrolled into a study where they wore sifilcon A silicone hydrogel lenses (Dk/t = 117), on a daily wear basis for 9 months. At all scheduled visits, photographs were taken of the superior, inferior, temporal, and nasal limbal regions which were then imported into Adobe Photoshop. A red-free filter was applied to enhance the contrast of the blood columns. In each quadrant, the length of the longest visible blood column was measured and the blood columns that penetrated >0.5 mm into the cornea were counted. A control group of 11 non-lens wearers was recruited. Their photographs were taken at the beginning of the study and 9 months later. An independent, masked observer assessed the photographs.

Results. There was a significant decrease in the maximum penetration of the blood column in all quadrants (p < 0.001) from baseline to the 9-month visit (e.g., superior: baseline 0.84 ± 0.39 mm; 9 months 0.63 ± 0.20 mm). There was also significant reduction in the number of visible blood columns longer than 0.5 mm in each quadrant (p < 0.001) from baseline to 9 months in all quadrants (e.g., superior: baseline 14.0 ± 8.2; 9 months 6.5 ± 6.0). The control group showed no change over time for the maximum blood column length (p = 0.638) or the number of columns >0.5 mm (p = 0.341).

Conclusions. A group of highly myopic subjects exhibited reduction in the maximum length and number of blood columns in the cornea when refit with a highly permeable silicone hydrogel material. The use of photography, along with Adobe Photoshop software, provides a reliable way of measuring corneal vascular responses over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To report the perspectives of optometrists, ophthalmologists and patients on a model of shared care for patients with chronic eye diseases.

Design, setting and participants: Qualitative study of a model of shared care between optometrists and ophthalmologists for patients with stable age-related macular degeneration, diabetic retinopathy and glaucoma, trialled by the Royal Victorian Eye and Ear Hospital in Melbourne during 2007–2009. Semi-structured interviews were conducted with optometrists, ophthalmologists and patients at completion of the project to obtain their perspectives on this model.

Results: Seventeen optometrists submitted expressions of interest to participate, and 12 completed web-based training modules and clinical observerships and adhered to specified examination and reporting protocols. All five participating ophthalmologists and 11 of the optometrists were interviewed. Ninety-eight patients participated and 37 were interviewed. Optometrists not only met ophthalmologists’ expectations but exceeded them, appropriately detecting and referring patients with additional, previously undetected conditions. Patients reported savings in travel time and were satisfied with the quality of care they received. Optometrists, ophthalmologists and patients indicated a general acceptance of shared care arrangements, although there were some issues relating to interprofessional trust.

Conclusions: Shared care between local optometrists and hospital-based ophthalmologists can help to reduce patient waiting time for review and offers an opportunity for these two groups of eye care professionals to collaborate in providing localised care for the benefit of patients. However, trust and relationship building need to be further developed.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To report the development of a new apparatus for non-invasive collection of human corneal epithelial cells.

Methods. Previous methods of non-invasive, irrigative corneal cell collection resulted in low cell yields limiting potential analysis. A new ocular surface cell collection apparatus (OSCCA) was designed to collect more epithelial cells from direct irrigation of the corneal surface to allow for clinical comparisons. Forty-five samples were obtained (unilateral or bilateral over seven visits) from five human participants. Cell yield, size, phenotype, and corneal staining (prior and post eye wash) were examined.

Results. On average 364 ± 230 epithelial cells were collected from the cornea per eye. Epithelial cell sizes ranged from 8.21 to 51.69 μm in diameter, and 67.30 to 2098.85 μm2 area. The proportion of corneal specific cells collected per sample was 75 ± 14% as determined by positive K3 expression with AE5. On average, 77 ± 0.2% of epithelial cells harvested were nucleated, the remainder were non-nucleated ghost cells. Corneal staining was reduced in the OSCCA-washed vs. contralateral non-washed eyes (p = 0.02).

Conclusions. The OSCCA allows collection of human corneal epithelial cells with significantly higher yields, and greater specificity than previously reported. Reduced corneal staining observed post eye-wash demonstrated the safety of the technique, and its ability to remove cells directly from the corneal surface. The OSCCA could provide an objective non-invasive method of investigating pathological changes, effects of topical therapeutics, and impact of contact lenses and care-solutions of the cells of the ocular surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To determine the types of contact lenses prescribed for infants (aged 0 to 5 years), children (6 to 12 years), and teenagers (13 to 17 years) around the world.

Methods. Up to 1000 survey forms were sent to contact lens fitters in each of 38 countries between January and March every year for 5 consecutive years (2005 to 2009). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form.

Results. Data were received relating to 105,734 fits [137 infants, 1,672 children, 12,117 teenagers, and 91,808 adults (age ≥18 years)]. The proportion of minors (<18 year old) fitted varied considerably between nations, ranging from 25% in Iceland to 1% in China. Compared with other age groups, infants tend to be prescribed a higher proportion of rigid, soft toric, and extended wear lenses, predominantly as refits for full-time wear, and fewer daily disposable lenses. Children are fitted with the highest proportion of daily disposable lenses and have the highest rate of fits for part-time wear. Teenagers have a similar lens fitting profile to adults, with the main distinguishing characteristic being a higher proportion of new fits. Orthokeratology fits represented 28% of all contact lenses prescribed to minors.

Conclusions. Patterns of contact lens prescribing to infants and children are distinctly different to those of teenagers and adults in a number of respects. Clinicians can use the data presented here to compare their own patterns of contact lens prescribing to minors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. Various methods have been used in clinical trials to collect time-sensitive subjective responses, including study diaries, telephone interviews, and use of text messaging. However, all of these methods are limited by the uncertainty of when the participants enrolled in the study actually record their responses. This technical note reports on the utility of the BlackBerry smartphone to collect such data and why such a system provides advantages over other methods to report subjective ratings in clinical studies.

Methods. The Centre for Contact Lens Research developed an on-line web-enabled system that permits participants to record and immediately transmit subjective rating scores in numerical form directly into a web-enabled database. This, combined with the utility of BlackBerrys, enabled time-specific e-mail requests to be sent to the study participants and then for that data to be simultaneously transmitted to the web-enabled database. This system has been used in several clinical trials conducted at the Centre for Contact Lens Research, in which data were collected at various times and in several specific locations or environments.

Results. In the clinical trials conducted using this system, participants provided responses on 97.5% of occasions to the requests for data generated by the automated system. When the request was for data on a set date, this method resulted in responses of 84.1% of the time.

Conclusions. The series of clinical trials reported here show the benefits of the utilization of the BlackBerry to collect time- or environment-sensitive data via a web-enabled system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To investigate whether the inclusion of a rub and rinse step before contact lens disinfection has an impact on solution-induced corneal staining.

Methods. This was a prospective, double-masked, single investigator study. Twenty participants were recruited for two visits, where balafilcon-A lenses were worn bilaterally for 2 h. Each pair of lenses was prepared using two different methodologies. The “control” lens was transferred from the blister pack directly into a storage case containing polyhexamethylene biguanide-based lens care solution. The contralateral “test” lens was rubbed and simultaneously rinsed using the same polyhexamethylene biguanide-based care solution, for either 60 s (visit 1) or 20 s (visit 2). Both lenses were then soaked in the solution overnight. After baseline corneal staining assessments, the lenses were inserted following a randomized contralateral model. After 2 h, lenses were removed, corneal staining was regraded, and comfort scores were obtained.

Results. Rubbed and rinsed test lenses induced significantly less corneal staining than control lenses for all participants during visit 1 (mean ± SD: 516 ± 843 vs. 2170 ± 902; p < 0.001) and visit 2 (522 ± 417 vs. 2091 ± 965; p < 0.001). There was no significant difference between the test lenses during visits 1 and 2 (p = 0.72) or controls (p = 0.50). Comfort scores did not differ between eyes (p > 0.05).

Conclusions. Corneal staining induced after 2 h of lens wear with the combination of balafilcon-A and polyhexamethylene biguanide-based lens care solution can be significantly reduced by including a rub and rinse step before overnight soaking. Further work is required to establish the longevity of this effect during the monthly wearing cycle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To assess eye care practitioners (ECPs) recommendations for replacement frequency (RF) of silicone hydrogel (SH) and daily disposable (DD) lenses in Canada and the U.S. and to compare noncompliance (NC) with manufacturer recommended RF by the ECP and patient, and the reasons given for NC.

Methods. Invitations to participate were sent by e-mail to ECPs in Canada and the U.S. Twenty patient surveys were sent to 420 ECPs, and 2232 eligible surveys were received from 216 ECPs (26% Canada, 74% U.S.). Questions related to patient demographics, lens type, wearing patterns, ECP instructions for RF, and actual patient RF. ECPs provided lens information and their recommendation for RF after the surveys were completed and sealed in envelopes. Responses were anonymous.

Results. DD accounted for 18% (Canada) vs. 16% (U.S.) of wearers (p > 0.05); 35% (Canada) vs. 45% (U.S.) wore 2-week replacement SH (2WR; p = 0.011); and 47% (Canada) vs. 39% (U.S.) wore 1-month replacement SH (1MR) lenses (p = 0.025). Thirty-four percent (Canada) vs. 18% (U.S.) of ECPs recommended longer RFs than the manufacturer recommended RF for 2WR lens wearers (p < 0.001); 6% (Canada) vs. 4% (U.S.) for DD wearers; and 2% (Canada) vs. 1% (U.S.) for 1MR lens wearers. NC rates for actual RFs reported by patients were not different between countries (p > 0.05) and were lowest for DD (13% Canada, 12% U.S.), followed by 1MR (33% Canada, 28% U.S.). The highest NC rates were with 2WR (50% Canada, 52% U.S.). The most frequent reason for NC with 2WR and 1MR was “forgetting which day to replace lenses” (54% Canada, 53% U.S.) and in DD wearers “to save money” (56% Canada, 29% U.S., p < 0.001).

Conclusions. 1MR lenses are more frequently prescribed in Canada. ECPs in Canada were NC with 2WR lenses more frequently than U.S. ECPs, but patient NC rates were the same in both countries for all lens types. ECP and patient NC rates were highest for 2WR lens wearers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. Little is known about the contact lens prescribing habits of optometrists in North America. The purpose of this survey was to obtain data on the types of lenses and solutions prescribed by Canadian optometrists.

Methods. One thousand Canadian optometrists were surveyed annually over seven consecutive years (2000 to 2006; n = 7000) on their contact lens prescribing preferences. Each survey requested a range of information about the contact lenses prescribed to the first 10 patients after its receipt.

Results. Over this time period, 1008 (14.4%) of the surveys were returned, providing data on 9383 fits. During the seven-year period, the ratio of male:female fits was 1:2 (3123:6217, 43 not reported), with a mean age of 31.3 ± 13.6 years (range 2 to 82 years). The ratio of new fits to refits was 2:3 (3780:5518, 85 not reported), with 91.3% of all fits being soft contact lenses (SCL). Of the SCL fits, 59.5% were spherical, 28.5% toric, 9.7% multifocal, and 2.3% cosmetic tints. Gas permeable (GP) fits were 46.6% spherical, 18.6% toric, 19.5% multifocal, and 6.6% were for orthokeratology (OK). Over the seven-year period, SCL prescribed for continuous wear (CW) increased from 3.2% to 14.3% between 2000 and 2004 and reduced to 8.1% in 2006, for all fits. The use of mid-water content (MWC) materials decreased from 34.6% to 2.7% and the use of silicone hydrogel (SH) lenses increased from 61.4% to 96.2%, for all CW fits. GP lens continuous wear increased from 0.7% to 30.6% of all GP lens fits by 2006. Daily wear (DW) of SH lenses decreased from 49.6% (2000) to 33.7% (2004) and then increased to 86.1% in 2006, for SH fits. MWC SCL fit on a monthly planned replacement (PR) basis reduced in popularity over the seven-year period (75.0% to 39.9%) and in 2006 more patients were fit overall with SH lenses (42.9%). The use of non-PR SCL declined from 20.5% to 4.5% of all fits. Fitting of low-water content lenses also declined (15.1% to 7.0%). High-water content (5.4% to10.2%) and SH lenses (5.4% to 42.9%) both increased. By 2006, the majority of GP lenses fit were with high Dk (HDK) materials (50.3%).

Conclusions. The preferred contact lens modality for Canadian optometrists appears to be DW SCL, which are replaced monthly. The proportion of lenses used for CW peaked in 2004, with SH SCL being the preferred material. The market share for GP lenses remains relatively unchanged, with an increasing proportion used for OK and CW. The launch of DW SH lenses in 2004 resulted in a marked increase in their reported fits, with a similar effect following the launch of a HDK GP lens material for CW.