79 resultados para hydroxyapatite chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two-step chromatographic sequence is described for the purification of native lactose operon repressor protein from Escherichia coli cells. The first step involves Ni2+-based immobilized metal ion affinity chromatography of the soluble cytoplasmic extract. This method provides superior speed, resolution and yield than the established phosphocellulose cation-exchange chromatographic procedure. Anion-exchange chromatography is used for further purification to >95% purity. The identity and purity of the lactose repressor protein were demonstrated using sodium dodecylsulphate polyacrylamide electrophoresis, crystallization, tryptic finger-printing mass spectrometry, and inducer binding assays. The purified lac repressor exhibited inducer sensitivity for operator DNA binding and undergoes a conformational change upon inducer binding. By all these extensive biochemical criteria, the purified protein behaves exactly as that described for the Escherichia coli lactose operon repressor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cellular lipids frequently co-purify with lipid binding proteins isolated from tissue extracts or heterologous host systems and as such hinder in vitro ligand binding approaches for which the apo-protein is a prerequisite. Here we present a technique for the complete removal of unesterified fatty acids, phospholipids, steroids and other lipophilic ligands bound to soluble proteins, without protein denaturation. Peroxisome proliferator activated receptor gamma ligand binding domain and intracellular fatty acid binding proteins were expressed in an Escherichia coli host and completely delipidated by hydrophobic interaction chromatography using phenyl sepharose. The delipidation procedure operates at room temperature with complete removal of bound lipids in a single step, as ascertained by mass spectrometry analysis of organic solvent extracts from purified protein samples. The speed and capacity of this method makes it amenable to scale-up and high-throughput applications. The method can also easily be adapted for other lipid binding proteins that require delipidation under native conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-performance liquid chromatography (HPLC) with tris(2,2-bipyridyl)ruthenium(II) chemiluminescence detection methodology is reported for the determination of the atypical antipsychotic drug quetiapine and the observation of its major active and inactive metabolites in human urine and serum. The method uses a monolithic chromatographic column allowing high flow rates of 3mL min−1 enabling rapid quantification. Flow injection analysis (FIA) with tris(2,2-bipyridyl)ruthenium(II) chemiluminescence detection and HPLC time of flight mass spectrometry (TOF-MS) were used for the determination of quetiapine in a pharmaceutical preparation to establish its suitability as a calibration standard. The limit of detection achieved with FIA was 2×10−11 mol L−1 in simple aqueous solution. The limits of detection achieved with HPLC were 7×10−8 and 2×10−10 mol L−1 in urine and serum, respectively. The calibration range for FIA was between 5×10−9 and 1×10−6 mol L−1. The calibration ranges for HPLC were between 1×10−7–1×10−4 and 1×10−8–1×10−4 mol L−1 in urine and serum, respectively. The quetiapine concentrations in patient samples were found to be 3×10−6 mol L−1 in urine and 7×10−7 mol L−1 in serum. Without the need for preconcentration, the HPLC detection limits compared favourably with those in previously published methodologies. The metabolites were identified using HPLC-TOF-MS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polystyrene behaviour in reversed phase high performance liquid chromatography was influenced mainly by the solvent system, but secondary affects were observed depending on the stationary phase. A variety of reversed phase columns were investigated using mobile phase combinations of dichlorom ethane-methanol, dichloromethane-acetonitrile, ethyl acetate-methanol and ethyl acetate-acetonitrile. Several different modes of behaviour were observed depending on the polymer solubility in the solvent system. In the dichloromethane-methanol solvent system, polymer-stationary phase interactions only occurred when the molecules had pore access. Retention of excluded polystyrene depended on the kinetics of precipitation and redissolution of the polymer. Peak splitting and band broadening occurred when the kinetics were slow and molecular weight separations were limited !o oligomers and polystyrenes lower than 5-10(4) dalton. Excellent molecular weight separations of polystyrenes were obtained using gradient elution reversed phase chromatography with a dichloromethane-acetonitrile mobile phase on C18 columns. The retention was based on polymer-stationary phase interactions regardless of the column pore size. Separations were obtained on large diameter pellicular adsorbents that were almost as good as those obtained on porous adsorbents, showing that pore access was not essential for the retention of high molecular weight polystyrenes. In the best example, the separation ranged from the monomer to 10(6) dalton in a single analysis. Very little adsorption of excluded polymers was observed on C8 or phenyl columns. Polystyrene molecular weight separations to 7-10(5) dalton were obtained in an ethyl acetate-acetonitrile solvent system on C18 columns. Adsorption was responsible for retention. When an ethyl acetate-methanol solvent system was used, no molecular weight separations were obtained because of complex peak splitting. Reversed phase chromatography was compared to size exclusion chromatography for the analysis of polydisperse polystyrenes. Similar results were obtained using both methods. However, the reversed phase method was less sensitive to concentration effects and gave better resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis covers the development of the traditionally fluorescent bis(8-quinolinol-5-sulfonic acid) magnesium (II) fluorophore as a chemiluminescent emitter. A brief description of luminescence spectroscopy and its application to analytical chemistry lays the foundation to the discussion of the results obtained herein. This includes the synthesis and identification of two so called ‘water soluble’ aryl oxamides 2,2’-oxalyl-bis(trifluoromethanesulfonyl) imino] ethylene-bis(N- methylpyridinium) trifluoromethane sulfonate (PETQ) and 2,2’-oxalyl-bis(trifluoromethanesulfonyl) imino]ethylene-bis(N-pyridinium) chloride (PETH), previously developed for the US navy as a possible emergency light source, yet the synthetic methodology were incomplete. The inconsistencies of the synthetic methods for PETQ and PETH were overcome with yields satisfactory for their preliminary analytical evaluation. The evaluation of these aryl oxamides, including 4,4’-oxalyI- bis[(trifluoromethanesulfonyl) imino]ethylene-bis(l-methyM-benzylpiperidinium) trifluoromethanesulfonate (BPTQ), 4,4’-oxalyl-bis [(trifluoromethylsulfonyl)imino] ethylene-bis(N-methylmorpholinium)trifluoromethanesulfonate (METQ) and the oxalate bis(2,4,6-trichlorophenyl) oxalate (TCPO) were performed with the peroxyoxalate chemiluminescent reaction using bis(8-quinolinol-5-sulfonic acid) magnesium (II) as the fluorophore. A univariate optimisation of this system resulted in 0,0082 mol 1-1 the detection limit of magnesium in the absence of cationic surfactants and 0.0041 mol 1-1 in their presence for the majority of these compounds. The oxamides were found to be insoluble in water with long ulrasonication periods required to dissolve the compound, with solvents such as acetonitrile preferred. The determination of other chemiluminescent metal-8HQS chelates to replace magnesium -8HQS in the peroxyoxalate were limited to Al (III), Cd (II), Ca (II), In (II) and Zn (II), unfortunately these metals all possessed poorer detection limits than those obtained using magnesium The base reaction conditions used for the flow injection system with chemiluminescent detection were transferred to an ion chromatographic configuration for the separation of magnesium from other cations on an exchange column. After a univariate and simplex optimisation of these conditions, the detection limit of magnesium was found to be 0.0411 mol 1-1 which was less than the limits that could be achieved with fluorescent detection, The further development of this reaction to incorporate the displacement of magnesium from Mg-EDTA by other metals that possessed a higher conditional stability constant than magnesium also proved to be problematic with interferences from not only EDTA but from the eluant (lactic acid) from the cation column. Using this system the detection limits of the displacing metals were found to be in the order of 10 mg 1-1 which was substantially less that what was observed when exactly the same configuration was used with fluorescent detection. The final component of the thesis entails the discussion of the background emission that results from the reaction of oxamides/oxalates with hydrogen peroxide. A detailed investigation into the reaction of TCPO and hydrogen peroxide in the presence of various additives, such as imidazole , heavy atoms and triethylamine illustrated the existence of a further intermediate in fee mechanism for this reaction. The species responsible for this emission was attributed to the degradation product 2,4,6-trichlorophenyi of TCPO, which was supported by the non-existent background present with the oxamides that do not contain this degradation product.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined effects of hydrogen and air flow rates on the peak response of selected neutral lipid classes (triacylglycerol, diacylglycerol, monoacylglycerol, free fatty acids, and ethyl esters) were studied to optimize and calibrate the Iatroscan Mk-6s Chromarod system for the qualitative and quantitative analysis of lipid classes by thin-layer chromatography (TLC) with flame ionization detection in fish oil during the transesterification process. Air flow rate of 2 L/min, hydrogen flow rate of 150-160 mL/min, and scan rate of 30 s/rod were found to be the optimum conditions. All samples were also analyzed by high performance liquid chromatography (HPLC) with evaporative light scattering detection. Quantitative results obtained by TLC with the flame ionization detection method were comparable to those obtained from HPLC with evaporative light scattering detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydroxyapatite (HA) was coated on the surface of a titanium-niobium (Ti-Nb) alloy by a sol-gel process. Triethyl phosphite and calcium nitrate were used as the phosphorus (P) and calcium (Ca) precursors respectively to prepare a Ca/P sol solution. The Ti-Nb alloy was dip-coated in the sol and heated at 600°C for 30 minutes. X-ray diffraction (XRD) analysis indicated the major phase constituent of the coating after heat treatment was HA. Scanning electron microscopy (SEM) observation showed that a few cracks were distributed on the HA coating. The in-vitro bioactivity of the HA coated Ti-Nb alloy was assessed using a cell culture of SaOS-2 osteoblast-like cells. The density of cell attachment was determined by MTT assay; the cell morphology was observed by SEM. Results indicated that the density of cell attachment on the surface of the Ti-Nb alloy was significantly increased by HA coating. Cell morphology observation showed that cells attached, spread and grew well on the HA coated surface. It can be concluded that the HA coating improved the in-vitro bioactivity of Ti-Nb alloy effectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis encompasses the development of analytical instrumentation, software and chemical methodologies for the rapid determination of pharmaceuticals in process extracts. Sensitive detection of morphine, codeine, oripavine and thebaine was achieved by measuring the quantity of light emitted as a result of their reactions with potassium permanganate and tris(2,2'-bipyridyl)ruthenium(III).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of rapid analytical methodologies for the determination of plant bioactives including antioxidants, amino acids and opium alkaloids was investigated using novel flow analysis and liquid chromatographic techniques. These methodologies were applied to the wine, food and pharmaceutical industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resin acids are reported to be of major toxicological importance in pulp mill effluents for Rainbow Trout. Their determination, using a high performance liquid chromatographic method, is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes how a simple macroscopic working model can be constructed to demonstrate the operation of chromatography in the classroom. Since the resources for construction may vary from school to school, the effect of varying 'molecular size'and packing parameter on the operation of the'chromatography column'have been investigated to provide guidance for teachers in the selection of materials to construct your own macroscopic chromatography column. Macroscopic working models help students make the link between the macroscopic observables e.g. retention time) and the conceptual explanations of the phenomenon at the microscopic level, thus helping to overcome most of the confusion and misconceptions associated with chromatography.The column is effective because it can engage kineastic, visual and auditory learning modes.The working model presented here separates components on the basis of size; other models, which separate by shape, mass, type of material, etc, are also mentioned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, an activity based screening technique combining two-dimensional liquid chromatography (2DHPLC) with UV-absorbance and chemiluminescence detection was applied to study “Ristretto”, "Decaffeinatto” and “Volluto” espresso coffees. This technique, which coupled the separation power of 2DHPLC with the sensitivity and selectivity of the chemiluminescence detection, offers great potential for screening complex samples for antioxidant compounds. Detailed information regarding the complexity of the sample, and the variation between these three coffees could be obtained using this multidimensional-hyphenated method of analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HPLC with acidic potassium permanganate chemiluminescence detection was employed to analyse 17 Cabernet Sauvignon wines across a range of vintages (1971–2003). Partial least squares regression analysis and principal components analysis was used in order to investigate the relationship between wine composition and vintage. Tartaric acid, vanillic acid, catechin, sinapic acid, ethyl gallate, myricetin, procyanadin B and resveratrol were found to be important components in terms of differences between the vintages.