47 resultados para high-flow


Relevância:

40.00% 40.00%

Publicador:

Resumo:

 Light-load exercise training with blood flow restriction (BFR) increases muscle strength and size. However, the hemodynamics of BFR exercise appear elevated compared with non-BFR exercise. This questions the suitability of BFR in special/clinical populations. Nevertheless, hemodynamics of standard prescription protocols for BFR and traditional heavy-load exercise have not been compared. We investigated the hemodynamics of two common BFR exercise methods and two traditional resistance exercises. Twelve young males completed four unilateral elbow flexion exercise trials in a balanced, randomized crossover design: (a) heavy load [HL; 80% one-repetition maximum (1-RM)]; (b) light load (LL; 20% 1-RM); and two other light-load trials with BFR applied (c) continuously at 80% resting systolic blood pressure (BFR-C) or (d) intermittently at 130% resting systolic blood pressure (BFR-I). Hemodynamics were measured at baseline, during exercise, and for 60-min post-exercise. Exercising heart rate, blood pressure, cardiac output, and rate–pressure product were significantly greater for HL and BFR-I compared with LL. The magnitude of hemodynamic stress for BFR-C was between that of HL and LL. These data show reduced hemodynamics for continuous low-pressure BFR exercise compared with intermittent high-pressure BFR in young healthy populations. BFR remains a potentially viable method to improve muscle mass and strength in special/clinical populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a rapid and robust method for the determination of urea in spent haemodialysis fluid as a measure of the efficiency of haemodialysis treatments. A novel flow analysis instrument (which generates a pulsed solution flow) was coupled with a chemiluminescence detection system, based on the oxidation of urea with hypobromite. The ‘pulsed-flow chemiluminescence analyser’ exhibited high precision (1.6% relative standard deviation (R.S.D.) for a 1×10−5 M urea standard, n=10) and good limit of detection (9×10−7 M, S/N=3) as a result of the rapid and reproducible mixing of small volumes of reagent and sample at the point of detection. The proposed chemiluminescence technique and an established urease-based laboratory procedure were compared, and showed a very similar trend for the change in urea concentration during a typical haemodialysis treatment. The relative chemiluminescence response from the oxidation of species with similar structure has revealed the inherent selectivity of the light producing pathway, but a positive interference was obtained from protein when this technique was applied to the determination of urea in serum samples. Arginine was identified as the predominant source of this interference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. Studies in several parts of the world have examined variation in univariate descriptors of macroinvertebrate assemblage structure in perennially flowing stony streams across hierarchies of spatial scale using nested analyses of variance. However, few have investigated whether this spatial variation changes with time or whether these results are representative of habitats other than riffles or of other stream types, such as intermittently flowing streams.

2. We describe patterns in taxon richness and abundance from two sets of samples from stony streams in the Otway Range and the Grampians Range, Victoria, Australia, collected using hierarchical designs. Sampling of riffles was repeated in the Otways, to determine whether spatial patterns were consistent among times. In the Grampians, spatial patterns were compared between intermittent and perennially flowing streams (stream type) by sampling pools.

3. In the Otways streams, most variation in the dependent variables occurred between sample units. Patterns of variation among the other scales (streams, segments, riffles, groups of stones) were not consistent between sampling times, suggesting that they may have little ecological significance.

4. In the Grampians streams, variation in macroinvertebrate taxon richness and abundance differed significantly between replicate streams within each stream type but not between stream types or pools. The largest source of variation in taxon richness was stream type. Little variation occurred among sample units.

5. The pattern of most variation occurring among sample units is robust both to differences in the method of sampling and different dependent variables among studies and increasingly appears to be a property of riffles in stony, perennial upland streams. High variation among sample units (residual variation) limits the explanatory power of linear models and therefore, where samples are from a single sampling time, small but significant components of variation are unlikely to represent features of assemblage structure that will be stable over time.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Selective determination of morphine in the larvae of Calliphora stygia (Fabricius) (Diptera: Calliphoridae) using acidic potassium permanganate chemiluminescence detection coupled with flow injection analysis and high-performance liquid chromatography (HPLC) is described. Larvae of C. stygia were reared on minced meat substrates that had been spiked with varying concentrations of morphine. Morphine concentrations were chosen to reflect typical levels in human tissues from opiate overdose victims. After maturing on substrates, larvae were analyzed for the presence of morphine using chemiluminescence detection coupled to flow injection analysis and a rapid HPLC method. Analysis of the larval matrix by flow injection analysis with chemiluminescence detection indicated the presence of interferants capable of generating chemiluminescence. A rapid chromatographic separation with a monolithic column allowed selective determination of morphine in larvae using postcolumn chemiluminescence detection. Larvae of C. stygia reared on substrates containing morphine at concentrations of 500 and 1000 ng/g did not sequester morphine at detectable concentrations. Larvae reared on substrates containing morphine concentrations of 2500, 5000, and 10,000 ng/g tested positive for the drug at concentrations of 765, 2720, and 3010 ng/g, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quality of high pressure die castings is a function of many interdependent parameters. It has been observed that many defects detected in the HPDC castings can be tracked back to poor die temperature distribution in the critical areas. It has therefore been recommended that the development of a technique to directly control the critical features - making them less sensitive to thermal related parameters - be very beneficial to the HPDC industry. From the information obtained from thermal image (processing), computational fluid dynamics has been applied to design the layout of internal cooling system and assign the flow conditions such as flow rate and pressure of the cooling water. it is observed that CFD prediction provides an excellent insight into the thermal balance of the high pressure die casting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adrenergic amines found in extracts of Citrus aurantium (bitter orange) evoke analytically useful chemiluminescence with acidic potassium permanganate in the presence of polyphosphates. From corrected chemiluminescence spectra, the wavelength of maximum intensity for these reactions was 680 ± 5 nm and, using flow injection analysis methodology, limits of detection for synephrine, octopamine, tyramine and hordenine were found to be between 1 × 10−9 and 1 × 10−8 M. We have applied this method of detection to the rapid determination of synephrine in dietary supplements using monolithic column chromatography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of low-strain deformation behavior on curl and springback in advanced high strength steels (AHSS) was assessed using a bend-under-tension test. The effect of yielding behavior on curl and springback was examined by heat-treating two dual-phase steels to induce yield point elongation, while keeping a relatively constant tensile strength and a constant sheet thickness. A dual-phase and TRIP steel with similar initial thickness and tensile strengths were also examined to investigate the effect of work-hardening on curl and springback. It is shown that while current understanding limits prediction of curl and springback in bending under tension using only the initial sheet thickness and tensile strength, both the yielding and work-hardening behavior can affect the results. Explanations for these effects are proposed in terms of the discontinuous yielding and flow stress in the materials.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive and simple high performance liquid chromatography (HPLC) method was developed and validated for the determination of thalidomide in rat plasma. Chromatography was accomplished with a reversed-phase Hypersil C18 column. Mobile phase consisted of acetonitrile-10 mM ammonium acetate buffer (pH 5.50) (28:72, v/v), at a flow rate of 0.8 ml/min. Thalidomide was monitored by ultraviolet detector at 220 nm and it gave a linear response as a function of concentration over 0.02–50 μM. The limit of quantitation in rat plasma was 0.50 ng (0.02 μM plasma concentration) with an aliquot of 20 μl. Results from a 3-day validation study indicated that this method allows for simple and rapid quantitation of thalidomide with excellent accuracy and reliability. Using this validated assay, the effect of coadministered irinotecan (CPT-11) on the plasma pharmacokinetics of thalidomide in rats was determined. Coadministration of CPT-11 (intravenously, 60 mg/kg) increased the maximum plasma concentration (Cmax) and area under the plasma concentration–time curve (AUC0–10 h) of thalidomide by 32.29 and 11.66%, respectively, as compared to the control, but none of the effect of CPT-11 was of statistical significance (P > 0.05). Concomitant CPT-11 also caused a 10.04% decrease in plasma clearance (CL) and 14.51% decrease in volume of distribution (Vd) (P > 0.05). These results suggest that coadministered CPT-11 did not significantly alter the plasma pharmacokinetics of thalidomide in rats. Further studies are warranted to explore the pharmacokinetic and pharmacodynamic interactions between CPT-11 and thalidomide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The combined effect of scan speed, hydrogen and air flow rates on the flame ionization detection (FID) peak response of phospholipid classes has been studied to determine the optimum levels of these parameters. The phospholipid composition of different types of commercial lecithins, as well as lecithins combined with fish oils, has been analyzed by Iatroscan TLC‐FID Mark‐6s under optimized conditions. An air flow rate of 2 L/min, a hydrogen flow rate of 150–160 mL/min, and a scan speed of 30 s/rod seem to be the ideal conditions for scanning phospholipids with complete pyrolysis in the flame in the Mark‐6 model. Increasing the scan speed rapidly decreased the FID response. A hydrogen flow rate as high as 170 mL/min could be used at relatively low air flow rates (&#x003C2 L/min) and the response declined when both air flow rate and hydrogen flow rate increased simultaneously. Both linear and curvilinear relationships had highly significant correlations (p&#x003C0.01) with the sample load. Time course reactions, including the hydrolysis of phosphatidylserine using enzymes, can be successfully monitored by the Iatroscan TLC‐FID Chromarod system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microfluidics has the potential to enhance the understanding of the biological fluids under strain, due to the laminar nature of the fluid and the possibility to mimic the real conditions. We present advances on charaterization of a microfluidic platform to study high strain rate flows in the transport of biological fluids. These advances are improvements on the reproduction of a  constant extensional strain rate using micro contractions and development of 3D numerical models. The micro geometries have been fabricated in polydimethyl siloxame (PDMS) using standard soft-lithography techniques with a photolithographically patterned mold. A comparison of some microcontractions with different funnel characteristics is presented. The Micro Particle Image Velocimetry technique has been applied to validate the numerical simulations. We demonstrate the use of microfluidics in the reproduction of a large range of controllable extensional strains that can be used in the study of the effect of flow on biological fluids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biological fluids such as blood, proteins and DNA solutiosn moving within fluidic channels can potentially be exposed to high level of shear, extension or mixed stress, either in vitro such as industrial processing of blood products or in vivo such as ocurrs in some pathological conditions. This exposure to a high level of strain can trigger some reactions. In most of the cases the nature of the flow is mixed with shear and extensional components. The ability ot isolate the effects of each component is critical in order to understand the mechanisms behind the reactions and potentially prevent them. Applying hydrodynamic flow focusing, we present in this investigation the characterization of microchannels that allow study of the regions of high shear or high extension strain rate. Micro channels were fabricated in polydimethyl siloxane (PDMS)  using standard soft-lithography techniques with a photolithographically patterned mold. Characterization of the regions with high shear and high extension strain rate is presented. Computational Fluid Dynamics (CFD) simulations in three dimensions have been carried out to gain more detailed local flow information, and the results have been validated experimentally. A comparison between the numerical models and experiment and is presented. The advantages of microfluidic flow focusing in the study  of the effects of shear and extension strain rates for biological fluids are outlined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Cardiovascular disease is a process that has its origins in childhood. Endothelial dysfunction is the earliest detectable manifestation of cardiovascular disease. This study aimed to assess the impact of seasonal changes in physical activity (PA) and body composition on conduit artery endothelial function in children.

Method: We studied 116 children (70 girls aged 10.7 ± 0.3 yr and 46 boys aged 10.7 ± 0.3 yr) on two occasions; in the northern summer (June) and late autumn (November). We assessed flow-mediated dilation (FMD) using high-resolution Doppler ultrasound. Body composition was measured by dual-energy x-ray absorptiometry. PA was assessed using accelerometry.

Results: FMD (10.0% ± 4.3% to 7.9% ± 3.9%, P < 0.001) and PA (94.1 ± 34.8 to 77.8 ± 33.7 min·d-1, P < 0.01) decreased, while percentage body fat increased (27.6% ± 6.8% to 28.0% ± 6.6%, P < 0.001) between summer and autumn. Decreases in FMD correlated with decreases in high-intensity PA (r = 0.23, P = 0.04), and change in high-intensity PA was the only predictor of change in FMD. No relationships were evident between changes in body composition and FMD.

Conclusions: Vascular function decreased between summer and autumn in this cohort. There were no relationships between change in FMD and changes in body composition or low/moderate-intensity PA. The associations between FMD and high-intensity PA suggests that future interventions should encourage this form of behavior, particularly at the times of year associated with lower PA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thirty-nine CHF patients (New York Heart Association Functional Class = 2.3±0.5; left ventricular ejection fraction 28%±7%; age 65±11 years; 33:6 male:female) underwent 2 identical series of tests, 1 week apart, for strength and endurance of the knee and elbow extensors and flexors, VO2peak, HRV, FBF at rest, and FBF activated by forearm exercise or limb ischemia. Patients were then randomized to 3 months of resistance training (EX, n = 19), consisting of mainly isokinetic (hydraulic) ergometry, interspersed with rest intervals, or continuance with usual care (CON, n = 20), after which they underwent repeat endpoint testing. Combining all 4 movement patterns, strength increased for EX by 21±30% (mean±SD, P<.01) after training, whereas endurance improved 21±21% (P<.01). Corresponding data for CON remained almost unchanged (strength P<.005, endurance P<.003 EX versus CON). VO2peak improved in EX by 11±15% (P<.01), whereas it decreased by 10±18% (P<.05) in CON (P<.001 EX versus CON). The ratio of low-frequency to high-frequency spectral power fell after resistance training in EX by 44±53% (P<.01), but was unchanged in CON (P<.05 EX versus CON). FBF increased at rest by 20±32% (P<.01), and when stimulated by submaximal exercise (24±32%, P<.01) or limb ischemia (26±45%, P<.01) in EX, but not in CON (P<.01 EX versus CON).