53 resultados para amperometric biosensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a multilayer localized surface plasmon resonance (LSPR) graphene biosensor that includes a layer of graphene sheet on top of the gold layer, and the use of different coupled configuration of a laser beam. The study also investigates the enhancement of the sensitivity and detection accuracy of the biosensor through monitoring biomolecular interactions of biotin-streptavidin with the graphene layer on the gold thin film. Additionally, the role of thin films of gold, silver, copper and aluminum in the performance of the biosensor is separately investigated for monitoring the binding of streptavidin to the biotin groups. The performance of the LSPR graphene biosensor is theoretically and numerically assessed in terms of sensitivity, adsorption efficiency, and detection accuracy under varying conditions, including the thickness of biomolecule layer, number of graphene layers and operating wavelength. Enhanced sensitivity and improved adsorption efficiency are obtained for the LSPR graphene biosensor in comparison with its conventional counterpart; however, detection accuracy under the same resonance condition is reduced by 5.2% with a single graphene sheet. This reduction in detection accuracy (signal to noise ratio) can be compensated for by introducing an additional layer of silica doped B2O3 (sdB2O3) placed under the graphene layer. The role of prism configuration, prism angle and the interface medium (air and water) is also analyzed and it is found that the LSPR graphene biosensor has better sensitivity with triangular prism, higher prism angle, lower operating wavelength and larger number of graphene layers. The approach involves a plot of a reflectivity curve as a function of the incidence angle. The outcomes of this investigation highlight the ideal functioning condition corresponding to the best design parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Localized surface plasmon resonance (LSPR) is a promising detection method for label-free sensing of biomolecules. In this paper, a multilayer design for a LSPR biosensor is presented. In the proposed design, a periodic array of dielectric grating is incorporated on top of a graphene layer in the biosensor. The aim is to improve sensitivity of the LSPR biosensor through monitoring biomolecular interactions of biotin-streptavidin. Sensitivity improvement is obtained for the proposed LSPR biosensor compared with conventional SPR counterparts. In addition, to optimize the design, we have investigated grating geometry including volume factor and grating depth. The outcome of this investigation identifies ideal functioning conditions corresponding to the best design parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, S-parameters investigation of a variable incidence angle multilayer SPR biosensor is presented. Both magnitude and phase of the S-parameters are taken into account in the investigation. The work presented in this paper is the first attempt to apply S-parameters analysis to a multilayer SPR biosensor. The goal is to improve sensitivity through involving S-parameters including their phase values. In addition, further investigation is carried out to understand the relationship between the S-parameters and thickness of biomolecular layer and also the design parameters including the number of graphene layers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Designed a multilayer SPR biosensor to improve the detection sensitivity and accuracy simultaneously. Developed a design procedure to identify optimum design parameters for SPR biosensing. Devised a new detection measurement technique based on S-parameters for SPR biosensing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the sensitivity enhancement of a variable incidence angle subwavelength grating based multilayer surface plasmon resonance biosensor (SPRB). In the proposed design, a periodic array of subwavelength grating is integrated on top of a layer of graphene sheet in the multilayer SPR biosensor. The performance of the biosensor is investigated through monitoring the biomolecular interactions of cDNA-ssDNA interactions on its surface. The sensitivity improvement is indicated by the shift of the resonance peak angle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a subwavelength grating based multilayer surface plasmon resonance biosensor (SPRB) which includes a periodic array of subwavelength grating on top of a layer of graphene sheet in the biosensor. The proposed biosensor is named grating-graphene SPRB (GG-SPRB). The aim of the proposed multilayer structure is to improve the sensitivity of the SPRB through monitoring of the biomolecular interactions of DNA hybridization. Significant sensitivity improvement is obtained for the GG-SPRB compared with the conventional SPRB. The result of the numerical investigation of the GG-SPRB is presented and compared with a theoretically developed multilayer matrix formalism, and a good agreement has been observed. In addition, an optimization of the grating dimensions including volume factor, grating depth, grating angle, grating period, and grating geometry (e.g., rectangular, sinusoidal and triangular) is presented. The outcome of the investigation presented in this paper identifies desired functioning conditions corresponding to the best design parameters for the GG-SPRB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Graphene is scientifically and commercially important because of its unique molecular structure which is monoatomic in thickness, rigorously two-dimensional and highly conjugated. Consequently, graphene exhibits exceptional electrical, optical, thermal and mechanical properties. Herein, we critically discuss the surface modification of graphene, the specific advantages that graphene-based materials can provide over other materials in sensor research and their related chemical and electrochemical properties. Furthermore, we describe the latest developments in the use of these materials for sensing technology, including chemical sensors and biosensors and their applications in security, environmental safety and diseases detection and diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multilayer surface plasmon resonance biosensor (SPRB) incorporating a grating-graphene configuration is investigated for enhanced sensitivity. The numerical analysis of the impact of integrating a periodic array of subwavelength grating on top of a layer of graphene sheet for improving sensitivity is presented. The result of monitoring the biomolecular interactions of DNA hybridization is compared against the outcome of the conventional SPRB, a graphene-based multilayer SPRB, and a multilayer layer grating SPRB, and is mathematically validated. It is demonstrated that the inclusion of a grating and graphene layer on top of the gold thin film is an excellent candidate for a highly sensitive SPRB. To achieve further enhancement of sensitivity, the subwavelength grating is numerically optimized against its geometry including grating configurations (rectangular, sinusoidal, and triangular), grating depth, volume factor, and grating period. © 2014 Taylor & Francis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive electrochemical acetylcholinesterase (AChE) biosensor based on a reduced graphene oxide (rGO) and silver nanocluster (AgNC) modified glassy carbon electrode (GCE) was developed. rGO and AgNC nanomaterials with excellent conductivity, catalytic activity and biocompatibility offered an extremely hydrophilic surface, which facilitated the immobilization of AChE to fabricate the organophosphorus pesticide biosensor. Carboxylic chitosan (CChit) was used as a cross-linker to immobilize AChE on a rGO and AgNC modified GCE. The AChE biosensor showed favorable affinity to acetylthiocholine chloride (ATCl) and could catalyze the hydrolysis of ATCl. Based on the inhibition effect of organophosphorus pesticides on the AChE activity, using phoxim as a model compound, the inhibition effect of phoxim was proportional to its concentration ranging from 0.2 to 250 nM with a detection limit of 81 pM estimated at a signal-to-noise ratio of 3. The developed biosensor exhibited good sensitivity, stability and reproducibility, thus providing a promising tool for analysis of enzyme inhibitors and direct analysis of practical samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract A simple, signal-off and reusable electrochemical biosensor was developed for sensitive and selective detection of mercury(II) based on thymine-mercury(II)-thymine (T-Hg2+-T) complex and the remarkable difference in the affinity of graphene with double strand DNA (ds-DNA) and single strand DNA (ss-DNA). Our system was composed of ferrocene-tagged probe DNA and graphene. Due to the noncovalent assembly, the ferrocene-tagged probe ss-DNA was immobilized on the surface of graphene nanosheets directly and employed to amplify the electrochemical signal. In the presence of Hg2+, the ferrocene-labeled T-rich DNA probe hybridized with target probe to form ds-DNA via the Hg2+-mediated coordination of T-Hg2+-T base pairs. As a result, the duplex DNA complex kept away from the graphene surface due to the weak affinity of graphene and ds-DNA, and the redox current decreased substantially. Meanwhile, the graphene decorated GCE surface was released for the reusability. Under the optimal conditions, the proposed sensor showed a linear concentration range from 25 pM to 10 μM with a detection limit of 5 pM for Hg2+ detection. The strategy afforded exquisite selectivity for Hg2+ against other metal ions in real environmental samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel strategy for selective and sensitive electrochemical lead ion (Pb2+) biosensor was developed based on the single-stranded DNAzyme catalytic beacon. A DNAzyme that requires Pb2+ for activation was selected and labeled with redox-active ferrocene (Fc) for signal transducer. The Fc-labeled single-stranded DNAzyme (Fc-ssDNAzyme) was self-assembled through SAu bonding on a gold electrode surface. In the presence of Pb2+, the ssDNAzyme was activated and catalyzed the hydrolytic cleavage of the substrate strand, resulting in the removal of the substrate strand along with the Fc from the Au electrode surface. The dissociation of Fc caused a decrease of electrochemical signal ("signal-off"). Under the optimal conditions, the electrochemical signal of Fc decreased directly with the increasing Pb2+ concentration, exhibiting a linear response in the range of 0.5nM to 5μM with a detection limit of 0.25nM. This strategy is simple, sensitive and selective with the minimal reagents and working steps, thereby holds great potential for Pb2+ detection in real environmental sample analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Remote telemonitoring holds great potential to augment management of patients with coronary heart disease (CHD) and atrial fibrillation (AF) by enabling regular physiological monitoring during physical activity. Remote physiological monitoring may improve home and community exercise-based cardiac rehabilitation (exCR) programs and could improve assessment of the impact and management of pharmacological interventions for heart rate control in individuals with AF.

Objective: Our aim was to evaluate the measurement validity and data transmission reliability of a remote telemonitoring system comprising a wireless multi-parameter physiological sensor, custom mobile app, and middleware platform, among individuals in sinus rhythm and AF.

Methods: Participants in sinus rhythm and with AF undertook simulated daily activities, low, moderate, and/or high intensity exercise. Remote monitoring system heart rate and respiratory rate were compared to reference measures (12-lead ECG and indirect calorimeter). Wireless data transmission loss was calculated between the sensor, mobile app, and remote Internet server.

Results: Median heart rate (-0.30 to 1.10 b∙min-1) and respiratory rate (-1.25 to 0.39 br∙min-1) measurement biases were small, yet statistically significant (all P≤.003) due to the large number of observations. Measurement reliability was generally excellent (rho=.87-.97, all P<.001; intraclass correlation coefficient [ICC]=.94-.98, all P<.001; coefficient of variation [CV]=2.24-7.94%), although respiratory rate measurement reliability was poor among AF participants (rho=.43, P<.001; ICC=.55, P<.001; CV=16.61%). Data loss was minimal (<5%) when all system components were active; however, instability of the network hosting the remote data capture server resulted in data loss at the remote Internet server during some trials.

Conclusions: System validity was sufficient for remote monitoring of heart and respiratory rates across a range of exercise intensities. Remote exercise monitoring has potential to augment current exCR and heart rate control management approaches by enabling the provision of individually tailored care to individuals outside traditional clinical environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lab-on-a-chips are microfluidic devices which include biological laboratory functions on a single chip. They offer great advantages in terms of speed of analysis, precision, low sample and reagent consumption and automation of analysis. An efficient detection method in lab-on-a-chips is essential for the detection and quantification of chemical and biological parameters under examination. This review paper focuses on the recent research on optical detection techniques for LOC applications. Furthermore, several emerging detection paradigms which are still being matured are covered in this paper. Also, an analysis of the performance of different optical detection methods is given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microcantilever biosensors produce cantilever bending due to differential surface stress between upper and lower surfaces of the cantilever. The bending is associated with concentration of ligands and adsorbed ligand-receptor intermolecular forces. Sample volume sizes in clinical diagnostic applications are usually very minute requiring a highly sensitive microcantilever for disease detection. This paper investigates a number of parameters that influence the sensitivity of microcantilever biosensors. The parameters include length, thickness, shape, and material of the cantilever beam. Biosensors of varying parameters are modeled and simulated. The results show that increasing the length of the cantilever beam enhances its sensitivity. However, increasing the thickness of the cantilever beam reduces its sensitivity. In static analysis, the shape of the cantilever beam does not notably impact upon its sensitivity. Also, using materials with lower Young’s modulus improves the sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this report, a novel chemical synthesis of polyaniline/gold nanocomposite is explored using ionic liquid (IL) 1-Butyl-3-methylimidazolium hexafluorophosphate. The direct chemical synthesis of polyaniline/gold nanocomposite was initiated via the spontaneous oxidation of aniline by AuCl4 − in IL. A nearly uniform dispersion of polyaniline/Au particles with a diameter of 450 ± 80 nm was produced by this method, which indicates that this method is more suitable for controlling particle dimensions. It was also found that the electrical conductivity of the polyaniline/gold nanocomposite was more than 100 times higher than that of the pure polyaniline nanoparticles. The polyaniline/gold nanocomposite displays superior function in the biocatalytic activation of microperoxidase-11 because of the high surface area of the assembly and the enhanced charge transport properties of the composite material. We also report the possible application of polyaniline/gold nanocomposite as a H2O2 biosensor.