26 resultados para Xanthomonas campestris pv. phaseoli


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research analyses the mathematical model of the PV array with all the parameters involved, in the sequential steps. Then it is going to simulate the I-V and P-V characteristics of PV array in different climatology conditions, by using both MATLAB M-file and Simulink. Finally the capability of this method is demonstrated in simulated results, which are performed for both Single and Double Array PV system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microgrid (MG) power system with Distributed Generation (DG) plays an important role to provide reliable, secure, and low carbon emission energy supply for communities, in case of any failure or disturbance of energy supply from the main grid. At the same time, DG also contributes to several technical issues in the MG distribution network. Power quality (PQ) issues are one of the main technical challenges when integrating Renewable Energy (RE) sources in MG network. In this paper, the PQ issues like; power variation, voltage deviation, and Total Harmonic Distortion (THD) have been addressed by an impact analysis study on a typical solar PV MG power system in both on-grid and off-grid mode of operation. Analysis results from the study will be helpful in developing an independent MG power system with improved PQ conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past decade, the growing demand of Grid-connected photo voltaic (GCPV) system has been increasing due to an extensive use of renewable energy technologies for sustainable power generation and distribution. High-penetrated GCPV systems enhance the operation of the network by improving the voltage levels and reducing the active power losses along the length of the feeder. This paper aims to investigate the voltage variations and Total Harmonic Distortion (THD) of a typical GCPV system modelled in Power system simulator, PSS SINCAL with the change of level of PV integrations in a Low Voltage (LV) distribution network. Five different case studies are considered to investigate the impact of PV integrations on LV nodes and the corresponding voltage variations and harmonics. In addition, this paper also explores and benchmarks the voltage improvement techniques by implementing On Load Tap Changer (OLTC) with respective to the main transformer and addition of Shunt Capacitor (SC) at appropriate node points in LV network,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a hybrid method for Maximum Power Point Tracking (MPPT) of a Photovoltaic (PV) system which experiences non-uniform environmental conditions or partial shading conditions. The hybrid method combines two simple techniques with complementary strengths in achieving Global MPPT. Simulated Annealing (SA) has only recently been applied to PV MPPT and is very effective at locating global maxima with limited implementation complexity. Perturb and Observe (P&O) is a very common technique which provides continuous tracking of the MPP in a simple and easy to implement manner. The P&O method is generally incapable of locating global maxima, and the SA based method is unable to perform continuous searching. By merging these techniques in a hybrid MPPT method consisting of a global searching stage and a local searching stage, the tracking performance is improved compared to what each technique could achieve independently. Simulation results are presented to demonstrate the effectiveness of the proposed hybrid technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integration of solar PV and wind in to the distribution network is one of the most promising challenges of the modern power system networks to meet the growing demand of energy. Analysis of the effects of solar and wind intermittencies in the network are vital to maintain the power quality. Keeping this in view, this research paper focuses on impact analysis study of a typical power network with hybrid generation: solar PV and wind integration to quantify the level of impacts like power variation and voltage variation in the network through load flow analysis. Initially, a typical network model is developed using PSS-SINCAL and load profile analysis has been carried out based on the typical daily load profile and wind/solar profile to verify the power and voltage variations extensively in the network considering different scenarios. Results of this research analysis can be used as guidelines for utility grid to provide regulated and improved quality of energy supply by implementing appropriate planning of generation reserve and other control measures in the network

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a robust control design scheme for a multidistributed energy resource (DER) microgrid for power sharing in both interconnected and islanded modes. The scheme is proposed for micgrogrids consisting of photovoltaic (PV) units and wind turbine driven doubly fed induction generators (DFIGs). A battery is integrated with each of the wind and solar DER units. The control scheme has two levels: 1) one centralized multi-input–multi-output robust controller for regulating the set reference active and reactive powers and 2) local real and reactive power droop con-trollers, one on each DER unit. The robust control scheme utilizes multivariable H1 control to design controllers that are robust to the changes in the network and system nonlinearities. The effectiveness of the proposed controller is demonstrated through large-distur-bance simulations, with complete nonlinear models, on a test micro-grid. It is found that the power sharing controllers provide excellent performance against large disturbances and load variations during islanding transients and interconnected operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a simulated annealing (SA)-based global maximum power point tracking (GMPPT) technique designed for photovoltaic (PV) systems which experience partial shading conditions (PSC). The proposed technique is compared with the common perturb and observe MPPT technique and the particle swarm optimization method for GMPPT. The performance is assessed by considering the time taken to converge and the number of sample cases where the technique converges to the GMPP. Simulation results indicate the improved performance of the SA-based GMPPT algorithm, with arbitrarily selected parameters, in tracking to the global maxima in a multiple module PV system which experiences PSC. Experimental validation of the technique is presented based on PV modules that experience nonuniform environmental conditions. Additionally, studies regarding the influence of the key parameters of the SA-based algorithm are described. Simulation and experimental results verify the effectiveness of the proposed GMPPT method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maximum power point tracking (MPPT) is an important consideration in photovoltaic (PV) systems. These systems exhibit variable nonlinear current–voltage (I–V) and power–voltage (P–V) characteristics which vary with environmental conditions. The optimum operation of a PV system occurs when the system operates at the unique maximum power point (MPP) for the given environmental conditions. Key environmental conditions include the irradiance on the cell, temperature of the cell and any shading phenomenon. Shading can occur due to objects, dust or dirt and module mismatch arising from damage or manufacturing tolerances. These shading effects introduce further nonlinearity into the I–V and P–V characteristics of the system. An extensive variety of MPPT techniques has been proposed which vary from simple estimation techniques to advanced tracking techniques. In this chapter, the criteria for assessing the performance of MPPT methods are defined followed by a complete description and discussion of both techniques designed for uniform environmental conditions and those designed for nonuniform environmental conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to low electricity rates at nighttime, home charging for electric vehicles (EVs) is conventionally favored. However, the recent tendency in support of daytime workplace charging that absorbs energy produced by solar photovoltaic (PV) panels appears to be the most promising solution to facilitating higher PV and EV penetration in the power grid. This paper studies optimal sizing of workplace charging stations considering probabilistic reactive power support for plug-in hybrid electric vehicles (PHEVs), which are powered by PV units in medium voltage (MV) commercial networks. In this study, analytical expressions are first presented to estimate the size of charging stations integrated with PV units with an objective of minimizing energy losses. These stations are capable of providing reactive power support to the main grid in addition to charging PHEVs while considering the probability of PV generation. The study is further extended to investigate the impact of time-varying voltage-dependent charging load models on PV penetration. The simulation results obtained on an 18-bus test distribution system show that various charging load models can produce dissimilar levels of PHEV and PV penetration. Particularly, the maximum energy loss and peak load reductions are achieved at 70.17% and 42.95% respectively for the mixed charging load model, where the system accommodates respective PHEV and PV penetration levels of 9.51% and 50%. The results of probabilistic voltage distributions are also thoroughly reported in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electricity generation from solar energy has a great potential since it relies mainly on an abundant and clean source. However, there are many alterable and unalterable factors that can govern a PV module's efficiency. Dust is one of the location-dependent environmental factors that falls under the unalterable factors group. It can degrade the efficiency of a PV panel by causing physical damages, by attenuating the incoming solar radiation and by causing temperature rise, which results in changes in panel's electrical characteristics. Degree of degradation depends mainly on the deposition density, which is governed by various factors. Dust accumulation of 20 g/m2 on a PV panel reduces short circuit current, open circuit voltage and efficiency by 15–21%, 2–6% and 15–35% respectively. This work reviews, elaborates and summarizes the effects of dust on solar panel efficiency and the factors governing dust deposition on PV panel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the considerable recent attention to distributed power generation and interest in sustainable energy, the integration of photovoltaic (PV) systems to grid-connected or isolated microgrids has become widespread. In order to maximize power output of PV system extensive research into control strategies for maximum power point tracking (MPPT) methods has been conducted. According to the robust, reliable, and fast performance of artificial intelligence-based MPPT methods, these approaches have been applied recently to various systems under different conditions. Given the diversity of recent advances to MPPT approaches a review focusing on the performance and reliability of these methods under diverse conditions is required. This paper reviews AI-based techniques proven to be effective and feasible to implement and very common in literature for MPPT, including their limitations and advantages. In order to support researchers in application of the reviewed techniques this study is not limited to reviewing the performance of recently adopted methods, rather discusses the background theory, application to MPPT systems, and important references relating to each method. It is envisioned that this review can be a valuable resource for researchers and engineers working with PV-based power systems to be able to access the basic theory behind each method, select the appropriate method according to project requirements, and implement MPPT systems to fulfill project objectives.