63 resultados para Test reliability


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Breaks in prolonged sitting may have beneficial cardiometabolic and musculoskeletal health outcomes. Desk-based work settings are an important environment to promote and support breaks in sitting time. However, few studies have reported the psychometric properties of self-report measures to assess the frequency and duration of breaks from sitting. This study examined the concurrent validity and test-retest reliability of the Workplace Sitting Breaks Questionnaire (SITBRQ) designed to assess frequency and duration of breaks in sitting within desk-based work settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have estimated the reliability of performance in a commonly employed exercise test consisting of repeated sprints on a cycle ergometer. Eight recreationally active young men completed a practice trial and three more trials at 3- to 6-day intervals. Each trial consisted of two bouts of 30-s maximal-effort cycling on an electromagnetically braked cycle ergometer; the bouts were separated by 4 min of rest. The typical (standard) errors of measurement for peak and mean power between trials 2 to 4 were 2.5 and 1.7% respectively for the first bout and 1.9 and 1.8% for the second bout. These errors are substantially less than those in previous reliability studies of single 30-s sprint tests, probably because of differences in quality of ergometer. The typical errors for the difference between bouts (i.e., fatigue) for peak power and mean power were 3.0 and 2.5%, respectively. Typical errors for the average of the two bouts were 1.6 and 1.2% for peak and mean power respectively, which are small enough to give adequate precision for moderate treatment effects in studies with modest sample sizes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study examined the validity and reliability of survey items measuring one-week recall of physical activity (PA) and examined differences by weight status. A sub-aim of the study was to objectively assess the intensity of activity that most closely matches self-report. A questionnaire was administered to adults twice, three days apart. It was again administered after subjects wore a MTI/CSA accelerometer for seven days (n = 118). Several metabolic equivalent (MET) thresholds were applied to the accelerometer data. Agreement between test and re- test estimates of sufficient physical activity for health benefits (150 min/week) was high (% agreement > 90%). Correlations (rho) between total reported PA (mins/day) and accelerometer data were 0.29 (p < 0.05) among men and 0.25 (p < 0.05) among women. Among men, self- reported duration of moderate PA (3-5.9 METS) and accelerometer data were significantly correlated (rho = 0.40, p < 0.01), with no differences by weight status. Among women, a significant relationship was found only for those who were not overweight (rho = 0.52, p < 0.001). A significant correlation between self-reported duration of vigorous PA (6+ METS) and accelerometer data was only found for overweight men (rho = 0.40, p < 0.05). When lower MET thresholds were applied to the accelerometer data, women's reported duration of moderate-intensity PA was most strongly correlated with moderate PA (accelerometer) defined as 2.0-5.9 METS (rho = 0.39, p < 0.01). The recall instrument provides a consistent measure of physical activity and validation coefficients were similar to those obtained for other physical activity recall questionnaires. However, the ability to measure PA by self-report may vary by weight status.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sample of 917 children, aged 7 to 17 years, their parents, and their teachers each completed the appropriate version of the Strengths and Difficulties Questionnaire (SDQ), and 120 from each group did so again 2 weeks later. The results indicate that the SDQ demonstrates sound interinformant and test-retest reliability. Younger children, whose self-reports have not been assessed in previous studies, were reliable in their responding, although not as reliable as older children by these measures. However, the internal reliability of the various subscales, in particular, the peer problems subscale, is questionable for both older and younger child respondents. Overall the findings suggest that the SDQ's use may be extended cautiously to include self-report from younger children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Environmental factors are increasingly being implicated as key influences on children's physical activity. Few studies have comprehensively examined children's perceptions of their environment, and there is a paucity of literature on acceptable and reliable scales for measuring these. This study aimed to develop and test the acceptability and reliability of a scale which examined a broad range of environmental perceptions among children.
Methods: Based on constructs from ecological models, a survey incorporating items on children's perceptions of the physical and social environment at home and in the neighbourhood was developed. This was administered on two occasions, nine days apart, to a sample of 39 children aged 11 years (54% boys), attending a metropolitan Australian elementary school. The acceptability of the survey was determined by the proportion of missing responses to each item. The test-retest reliability of individual items, scores and scales were determined using Kappa statistics and percent agreement for categorical variables, and intraclass correlation coefficients (ICC) for continuous variables.
Results:
There were few missing responses to each question, with only 4% of all responses missing. Although some Kappa values were low, all categorical variables showed acceptable reliability when examined for percent agreement between test and retest (range 68%–100% agreement). Continuous variables all showed moderate to good ICC values (range 0.72–0.92).
Conclusion: Findings suggest this questionnaire is reliable and acceptable to children for assessing environmental perceptions relevant to physical activity among 11-year-old children.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background
The purpose of this study was to examine the reliability of stage of change (SOC) measures for moderate-intensity and vigorous physical activity in two separate samples of young adults. Staging measures have focused on vigorous exercise, but current public health guidelines emphasize moderate-intensity activity.
Method
For college students in the USA (n = 105) and in Australia (n = 123), SOC was assessed separately on two occasions for moderate-intensity activity and for vigorous activity. Test–retest repeatability was determined, using Cohen’s kappa coefficient.
Results
In both samples, the reliability scores for the moderate-intensity physical activity staging measure were lower than the scores for the vigorous exercise staging measure. Weighted kappa values for the moderate-intensity staging measure were in the “fair to good” range for both studies (0.50 and 0.45); for the vigorous staging measure kappa values were “excellent” and “fair to good” (0.76 and 0.72).
Conclusions
There is a need to standardize and improve methods for staging moderate-intensity activity, given that such measures are used in public health interventions targeting HEPA (health-enhancing physical activity).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Relationship separation is associated with substantial adult adjustment problems. The Psychological Adjustment to Separation Test (PAST) was developed as a self-report measure of 3 key dimensions of separation adjustment problems: lonely negativity, ex-partner attachment and coparenting conflict. Two independent samples (n = 219 and n = 169, respectively) of recently separated adults, 60% of whom had children, completed the PAST and other measures of general adjustment. Exploratory and confirmatory factor analyses demonstrated a replicable 3-factor structure, with each factor showing satisfactory test–retest and internal reliability and good convergent and discriminant validity. The PAST meets initial criteria for a potentially useful new measure of adult separation adjustment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study empirically investigated consumer involvement with a product class. Data was collected from 178 vehicle buyers. Reliability and factor analyses investigated the structure of the Bloch (1981) instrument and the dimensions underlying involvement. In terms of replication, the results suggest the reduced-item version of the instrument previously proposed by Shimp and Sharma (1983) is reliable and is a less excessive measurement instrument. Similar dimensions underlying involvement with the product class are reported here. The study extends previous work by obtaining similar results in a different cultural setting, producing findings from a more relevant sample, applying an additional method of data collection, and suggesting that the underlying dimensions may be temporally stable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Examines the development of a reliable, valid and feasible method for assessing physical activity among children ages 5-6 and 10-12 years. Information on the subjects of the study; Assessment of test-retest reliability of a parental proxy questionnaire and a children's self-report questionnaire; Utilization of accelerometry to assess the criterion validity of the questionnaire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To examine the test–retest reliability and construct validity of cervical active range of motion and isometric neck muscle strength as measured by the Multi Cervical Rehabilitation Unit (Hanoun Medical Inc., Ontario).
Design: A cross-sectional study.
Setting: Institutional practice.
Subjects: Twenty-one patients with neck pain and 25 healthy volunteers.
Methods: After a trial-run session, active range of motion (AROM) was measured in the subsequent two sessions, with 2–3 days in between. During each session, three measurements were taken for each direction (flexion, extension, lateral flexions and rotations). The measurement of isometric strength was after a 15-minute break following completion of the measurement of AROM. Three measurements were made for each of the six directions (flexion, extension, lateral flexions, protraction and retraction). The software of the Multi Cervical Rehabilitation Unit automatically recorded and calculated the maximum AROM and isometric strength.
Results: There was a good to high level of reliability in the measurement of AROM for both groups of subjects, with intraclass correlation coefficients (ICCs) ranging from 0.81 to 0.96. Results also demonstrated very good to excellent reliability in isometric strength measurement (ICCs ranged from 0.92 to 0.99). Moreover, there was a significant difference in isometric neck muscle strength (p = 0.001) and in AROM (p = 0.034) between the two groups.
Conclusions: The Multi Cervical Rehabilitation Unit was found to be reliable and valid for testing the cervical active range of motion and isometric neck muscle strength for both normal and patient subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Problems with visual perceptual skills have been shown to have a negative impact on the daily living skills of individuals and are, therefore, commonly assessed by occupational therapists. The purpose of this study was to examine two types of reliability (internal consistency and test-retest reliability) of three newly revised or developed adult visual perception tests. The participants were 50 healthy adults, aged 18 to 55 years, from Melbourne, Victoria, Australia. The participants completed the Developmental Test of Visual Perception - Adolescent and Adult (DTVP-A), the Motor-Free Visual Perception Test - Third Edition (MVPT-3) and the Test of Visual Perceptual Skills (non-motor) - Third Edition (TVPS-3). Internal consistency was examined using Cronbach's alpha calculations and test-retest reliability was analysed using Spearman rho non-parametric correlation coefficients.

The results indicated that the DTVP-A, the MVPT-3 and the TVPS-3 had total scale internal consistency correlation scores of 0.60 or higher (0.60, 0.69 and 0.63 respectively). The majority of the subscales of each test had lower correlation coefficients than the overall scores (ranging from 0.22 to 0.49). For the DTVP-A, MVPT-3 and TVPS-3 total scale scores, the test-retest reliability correlation coefficients were statistically significant (rho = 0.46, p<0.05; rho = 0.62, p<0.01; and rho = 0.59, p<0.01, respectively). Overall, the three visual perceptual tests exhibited low to moderate levels of internal consistency and test-retest reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To examine the relative reliability and absolute reliability of the Berg Balance Scale (BBS) and the Postural Assessment Scale for Stroke Patients (PASS) in chronic stroke patients. Method. A total of 52 mild to moderate stroke patients, who had a stroke more than 6 months previously, participated in the study. Both balance measures were administered twice, seven days apart, to the patients. A relative reliability index (intra-class correlation coefficient, ICC2,1) was used to examine the level of agreement between test and retest. Absolute reliability indices, including the Bland and Altman method, the standard error of measurement (SEM), and the smallest real differences (SRD), were used to define the extent to which a balance score varies on test-retest measurements. Results. Test-retest agreements were high (ICC2,1: BBS = 0.98; PASS = 0.97), indicating excellent agreement from a relative perspective. The SEM of the BBS and PASS, representing the smallest change threshold that indicates a real improvement for a group of individuals, were 2.4 and 1.1, respectively. The SRD of the BBS and PASS were 6.7 and 3.2, respectively, exhibiting the smallest change threshold that indicates a real improvement for a single individual. Conclusions. The test-retest agreements of the BBS and PASS were high in mild to moderate chronic stroke patients. The thresholds of both measures to detect real change are acceptable in research and clinical settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In six studies on the I Ching - an ancient Chinese system of divination - successful predictions of first- and second-hexagrams (i.e., hexagram hitting) based on pre-selections of corresponding descriptor-pairs have ranged from chance, to significantly above chance. No significant effect below chance has ever been found. Hexagram hitting has been predicted by measures such as paranormal belief, time perspective, and meaningfulness. Storm (2008a) found a near-significant aggregate hexagram hit rate of 27%. Though these results are encouraging, there has been no assessment of the reliability and validity of the main test instrument used in the I Ching studies, the Hexagram Descriptor Form (HDF). To test the validity of the HDF, three control methods were tested against the experimental method. Taking first- and second-hexagram hit rates together, three out of 22 tests on the experimental method (14%) were significant or near-significant. Three significant or near-significant outcomes out of 66 control tests (4.5%) were attributed to chance. Inter-rater reliability was tested using two I Ching experts who judged the 64 descriptor-pairs of the HDF for suitability against their corresponding hexagram readings. The correlation between judges' ratings was not significant (the mean rating ranged between 60% and 82%). Using the pooled data of six studies, the HDF was tested for possible selection and outcome biases. A selection bias was found, but no outcome biases were found. The I Ching and the HDF were considered suitable for parapsychological research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time spent in non-occupational sedentary behaviours (particularly television viewing time) is associated with excess adiposity and an increased risk of metabolic disorders among adults; however, there are no reviews of the validity and reliability of assessing these behaviours. This paper aims to document measures used to assess adults' time spent in leisure-time sedentary behaviours and to review the evidence on their reliability and validity. Medline, CINAHL and Psych INFO databases and reference lists from published papers were searched to identify studies in which leisure-time sedentary behaviours had been measured in adults. Sixty papers reporting measurement of at least one type of leisure-time sedentary behaviour were identified. Television viewing time was the most commonly measured sedentary behaviour. The main method of data collection was by questionnaire. Nine studies examined reliability and three examined validity for the questionnaire method of data collection. Test–retest reliabilities were predominantly moderate to high, but the validity studies reported large differences in correlations of self-completion questionnaire data with the various referent measures used. To strengthen future epidemiological and health behaviour studies, the development of reliable and valid self-report instruments that cover the full range of leisure-time sedentary behaviour is a priority.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to develop and test the reliability and validity of survey items that examine the frequency with which primary school-aged children play in particular outdoor locations. Parents reported the number of days their child spent playing in specified outdoor locations (i.e., yard at home, own street/court/footpath, and park/playground) out-of-school hours on weekdays and weekend days during a typical week. To test the reliability of these items, the survey was administered on two occasions, 2 weeks apart, to a sample of 53 parents of children attending primary schools located in metropolitan Melbourne. The validity study involved the completion of a log book by 46 parents of primary school children over a 1-week period. Two weeks later, the same sample of parents completed the survey items. The test–retest reliability of individual items was determined using intra-class correlation coefficients (ICC). The kappa statistic and percent agreement between responses were used to assess validity by comparing the information provided in the log book with that provided in the survey. Results from the two studies suggest that the survey was generally a reliable and valid instrument for assessing the frequency with which children play in particular locations especially at home or in the street. Evidence of the reliability and validity of items assessing where children play is novel and important considering the need to promote children's physical activity in a variety of settings.