47 resultados para Power distribution system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to low electricity rates at nighttime, home charging for electric vehicles (EVs) is conventionally favored. However, the recent tendency in support of daytime workplace charging that absorbs energy produced by solar photovoltaic (PV) panels appears to be the most promising solution to facilitating higher PV and EV penetration in the power grid. This paper studies optimal sizing of workplace charging stations considering probabilistic reactive power support for plug-in hybrid electric vehicles (PHEVs), which are powered by PV units in medium voltage (MV) commercial networks. In this study, analytical expressions are first presented to estimate the size of charging stations integrated with PV units with an objective of minimizing energy losses. These stations are capable of providing reactive power support to the main grid in addition to charging PHEVs while considering the probability of PV generation. The study is further extended to investigate the impact of time-varying voltage-dependent charging load models on PV penetration. The simulation results obtained on an 18-bus test distribution system show that various charging load models can produce dissimilar levels of PHEV and PV penetration. Particularly, the maximum energy loss and peak load reductions are achieved at 70.17% and 42.95% respectively for the mixed charging load model, where the system accommodates respective PHEV and PV penetration levels of 9.51% and 50%. The results of probabilistic voltage distributions are also thoroughly reported in the paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a hybrid DC microgrid consisting of a diesel generator with a rectifier, a solar photovoltaic (PV) system, and a battery energy storage system is presented in relation to an effective power management strategy and different control techniques are adopted to power electronic interfaces. The solar PV and battery energy storage systems are considered as the main sources of energy sources that supply the load demand on a daily basis whereas the diesel generator is used as a backup for the emergency operation of the microgrid. All system components are connected to a common DC bus through an appropriate power electronics devices (e.g., rectifier systems, DC/DC converter). Also a detailed sizing philosophy of all components along with the energy management strategy is proposed. Energy distribution pattern of each individual component has been conducted based on the monthly basis along with a power management algorithm. The power delivered by the solar PV system and diesel generator is controlled via DC-DC converterand excitation controllers which are designed based on a linearquadratic regulator (LQR) technique as as proportional integral (PI)controllers. The component level power distribution is investigatedusing these controllers under fluctuating load and solar irradiationconditions and comparative results are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a novel operation and control strategy for a renewable hybrid power system for a standalone operation. The proposed hybrid system consists of a wind turbine, a fuel cell, an electrolyzer, a battery storage unit, and a set of loads. The overall control strategy is based on a two-level structure. The top level is the energy management and power regulation system. Depending on wind and load conditions, this system generates reference dynamic operating points to low level individual subsystems. The energy management and power regulation system also controls the load scheduling operation during unfavorable wind conditions under inadequate energy storage in order to avoid a system blackout. Based on the reference dynamic operating points of the individual subsystems, the local controllers control the wind turbine, fuel cell, electrolyzer, and battery storage units. The proposed control system is implemented in MATLAB Simpower software and tested for various wind and load conditions. Results are presented and discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ring spinning has been and will continue to be an important system for making staple yarns from different fibers in the textile industry. But high power consumption and low productivity remain the two outstanding problems with ring spinning. Based on an analysis of power distribution during yarn winding in ring spinning, models for the ratio of energy consumption to yarn production over a full yarn package are established. Spindle speed, yarn count, and package diameter are the three key parameters affecting this ratio. The effects on energy consumption of these parameters are discussed through a case study. The energy-to-production ratio increases with increased package diameter but decreases with increased spindle speed and/or yarn count (tex). The results will help guide spinners in minimizing energy consumption in ring spinning.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The quality of drinking water generally degrades when it is delivered through a distribution system due to the decay of disinfectant, which subsequently allows the re-growth of microorganisms in the distribution system. A model that describes the changes that occur in the water quality in distribution system is needed to determine whether to enhance the treatment processes or to improve the distribution system so that microbiological criteria are met. This paper describes how chlorine decay kinetics are modeled and the model output is used in finding the elements that are contributing to the consumption of chlorine at the treatment plant other than the water itself; this allows better control of chlorine dosing at the treatment plant, which in tum will reduce the formation of disinfectant by-products. In addition, the model will accurately predict the decay due to the organic/inorganic and nitrogenous compounds that are remaining in the water at any point in the distribution system, which will indicate the status of the distribution system with respect to its chlorine consumption. Further, if re-chlorination is introduced in the distribution system downstream of the treatment plant, the model will predict the chlorine decay due to the slow reacting organic and nitrogenous compounds accurately.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A dynamic water quality model for drinking water distribution systems has been developed in this study, to include processes that occur in the bulk water, as well as those occurring in the biofilm of a distribution system. The model has been validated against water quality data obtained from extensive experimental studies conducted with biofilm reactors. Protein and carbohydrate densities in the biofilm represent biofilm biomass. This model is able to predict the disinfectant decay due to organic matter in the bulk water, as well as that due to biofilm. It simultaneously predicts the growth of biofilm in terms of carbohydrate and protein densities. While this model is complex enough to describe the water quality changes in a distribution system, it is also simple enough to be incorporated into a hydraulic model in order to describe the interaction between disinfectant and microbiological quality throughout a drinking water distribution system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

At present water treatment and distribution is of high priority to ensure that communities have access to safe and affordable drinking water. Current information states that in the United States a total annual cost of $36 billion (US) is spent replacing aging infrastructure, lost water from unaccounted-for leaks, corrosion inhibitors, internal mortar linings, external coatings, and cathodic protection as a result of corrosion. In order to reduce the cost incurred as a result of corrosion in the water distribution industry, it is essential that better corrosion management and preventative strategies are implemented. However through investigation of research previously undertaken by others, it was found that there was a lack of study of corrosion within distribution systems in the tropics taking into account the related seasonal temperature variations. To assist in the development of management strategies to improve the outcomes of drinking water distribution systems, the authors propose to implement a pilot study involving the installation of a corrosion reactor based on standard corrosion assessment technologies in a water distribution system located in the tropics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Effective disinfection planning and management in large, complex water distribution systems requires an accurate network water quality model. This model should be based on reaction kinetics, which describes disinfectant loss from bulk water over time, within experimental error. Models in the literature were reviewed for their ability to meet this requirement in real networks. Essential features were identified as accuracy, simplicity, computational efficiency, and ability to describe consistently the effects of initial chlorine dose, temperature variation, and successive rechlorinations. A reaction scheme of two organic constituents reacting with free chlorine was found to be necessary and sufficient to provide the required features. Recent release of the multispecies extension (MSX) to EPANET and MWH Soft's H2OMap Water MSX network software enables users to implement this and other multiple-reactant bulk decay models in real system simulations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Power loss of a distribution system can be reduced significantly by using optimum size and location of distributed generation (DG). Proper allocation of DG with appropriate size maximizes overall system efficiency. Moreover it improves the reliability and voltage profile of the distribution system. In this paper, IEEE 123 node test feeder has been considered to determine the optimum size and location of a synchronous machine based DG for loss reduction of the system. This paper also investigates the steady-state and dynamic voltage profile of that three phase unbalance distribution network in presence of DG with optimum size. This analysis shows that optimum size of DG at proper location minimizes the power loss as well as improves the dynamic voltage profile of the distribution system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a novel control design for D-STATCOM to ensure grid code-compatible performance of distributed wind generators. The approach considered in this paper is to find the smallest upper bound on the H norm of the uncertain system and to design an optimal linear quadratic Gaussian (LQG) controller based on this bound. The change in the model due to variations of induction motor (IM) load compositions in the composite load is considered as an uncertain term in the design algorithm. The performance of the designed controller is demonstrated on a distribution test system representative of the Kumamoto area in Japan. It is found that the proposed controller enhances voltage stability of the distribution system under varying operating conditions

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Smart micro-grids can produce 'renewable' energy and store them in power storage devices. Power loss, however, is a significant problem in power exchange among the micro-grids and between the macro-station and individual micro-grids. To optimally reduce the total power losses in such a power grid system, in this paper, a greedy coalition formation algorithm is proposed, which allows the macro-station to coordinate mutual power exchange among the micro-grids and between each micro-grid and the macro-station. Our algorithm optimizes the total power losses across the entire power grid, including the cost of charging and discharging power storage devices and power losses due to power transfers. The algorithm creates exchange pairs among the micro-grids, giving priority to pairs with higher power loss reduction per exchanged power unit. Through computer-based simulations, we demonstrate that the proposed approach significantly reduces the average power loss compared with the conventional noncooperative method. The simulations also demonstrate that the communications overhead of our proposal (due to negotiations aimed at forming coalitions) does not significantly affect the available communication resource. © 2014 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The demand for sport content by broadcasting organizations has undergone a major redefinition in the last 15-20 years. Television has become predominantly a private good, subject to deregulation and technological revolution. The traditional approach to presenting sport content predominantly live and exclusive through one distribution channel has evolved considerably into one represented now by a multi-faceted, multi-organizational approach. This paper will introduce the two markets of sport and broadcasting through the supply network of broadcasting rights and sports programming, and how this network is affected by the emerging broadcasting technology that is appearing in the digital environment. The era of digital broadcasting creates a significant alteration to the supply of broadcasting content developed by professional sport leagues, competitions and events. A number of emerging distribution system components linked to the digital environment can be identified and associated with sport broadcasting, all of which are having a profound impact on the way sport is being presented now and into the future. The various distribution components are introduced and examined in terms of their impact on the professional sport broadcasting markets. Each distribution component is addressed from the perspective of the regulatory, marketing, and economic impacts on channel management that apply.