48 resultados para Nonrandom two-liquid model


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose – To extend the discussion held in part 1, and develop a two-tier fifth-generation model of corporate entrepreneurship and innovation. Design/methodology/approach – The components that have been synthesized from a review of the literature in Part 1 are extended using evidence from the literature. These components are used to construct a two-tier model of corporate entrepreneurship and innovation; a macro model which presents the high-level environmental drivers of innovation and a micro model that discusses the contextual factors that underpin the corporate entrepreneurship and innovation process. Findings – From the analysis conducted in part 1 it is evident that there is a strong relationship between the role of the corporate entrepreneur and the innovation process. It is suggested that by separating the corporate entrepreneur from the innovation process previous models have been overly reductionist in their construction, and their utility has, as a consequence, been severely constrained. The study therefore combines the role and activities of the entrepreneur with the innovation process into a unified framework. In doing so the paper develops a two-tier fifth-generation model of corporate entrepreneurship and innovation. The final sections of the paper present the model's implications for management and suggestions for further research. Originality/value – This paper fulfils an identified gap in the literature, namely the development of a new holistic model of corporate entrepreneurship and innovation, which illustrates the environmental and contextual relationships between the corporate entrepreneur and the innovation process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single bubble injection simulations inside a minimally fluidized bed have been studied widely and are often used to validate the accuracy of different numerical models. Bubble shape, size and voidage distribution are the important parameters that are validated from the experiments. In the present work, the most widely used drag model (Gidaspow’s drag model) is compared to a new proposed slip flow drag model which takes into account the presence of the slip flow regime, often encountered in vacuum fluidized beds and characterised by Knudsen no. (Kn). Shape and size prediction of the bubble evolution inside the bed is carried out numerically by using the two fluid model, comparing the results predicted by the drag models. It is seen that the predictions are different for the two drag models only under high vacuum conditions corresponding to Kn in slip/transition flow regime. The predictions are also found sensitive to pressure gradient in the bed and fluid velocity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current bio-kinematic encoders use velocity, acceleration and angular information to encode human exercises. However, in exercise physiology there is a need to distinguish between the shape of the trajectory and its execution dynamics. In this paper we propose such a two-component model and explore how best to compute these components of an action. In particular, we show how a new spatial indexing scheme, derived directly from the underlying differential geometry of curves, provides robust estimates of the shape and dynamics compared to standard temporal indexing schemes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper studies a general two-period model of product line pricing with customer recognition. Specifically, we consider a monopolist who can sell vertically differentiated products over two periods to heterogeneous consumers. Each consumer demands one unit of the product in each period. In the second period, the monopolist can condition the price-quality offers on the observed purchasing behavior in the first period. In this setup, the monopolist can price discriminate consumers in two dimensions: by quality as well as by purchase history. We fully characterize the monopolist's optimal pricing strategy when there are two types of consumers. When the type space is a continuum, we show that there is no fully separating equilibrium, and some properties of the optimal contracts (price-quality pairs) are characterized within the class of partitional perfect Bayesian equilibria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT This paper addresses the issue of automatic identification of backlash in robot transmissions. Traditionally, the backlash is measured manually either by the transmission manufacturer or the robot manufacturer. Before the robot can be delivered to the end-customer, the backlash must be within specified tolerances. For robots with motor measurements only, backlash is an example of an uncontrollable behaviour which directly affects the absolute accuracy of the robot’s tool-centrepoint. Even if we do not attempt to bring backlash under real-time control in this paper, we will describe a method to automatically identify/estimate the backlash in the robot transmissions from torque and position measurements. Hence, only the transmissions that do not meet the backlash requirements in the automatic tests need to be checked and adjusted manually.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is an augmented platelet intracellular calcium response to serotonin stimulation in major depression. The role that calcium influx has in this process is not known. The objective of this study was to determine platelet calcium influx in response to serotonin by two methods, Mn2+ influx and 45Ca2+ uptake, in order to observe if the uptake response to serotonin was augmented in major depression by comparing the response to normal controls. The use of the two methods of calcium influx showed that serotonin stimulates calcium uptake into platelets. Furthermore, patients with major depression have significantly augmented platelet calcium uptake in response to serotonin. The interesting finding was that calcium uptake into platelets is biphasic, occurring immediately and after five minutes. These results may support the two pool model for calcium oscillations within cells whereby extracellular calcium is needed for intracellular calcium release, and for replenishment of depleted stores once intracellular calcium is released.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 This paper presents the development of a two-dimensional model of multilayer bulk heterojunction organic nanoscale solar cells, consisting of the thickness of active layer and morphology of the device. The proposed model is utilized to optimize the device parameters in order to achieve the best performance using particle swarm optimization algorithm. The organic solar cells under research are from poly (3-hexylthiophene) and [6,6]-phenyl C61-butyric acid methyl ester type which are modelled to be investigated for performance enhancement. A three-dimensional fitness function is proposed involving domain size and active layer thickness as variables. The best results out of 20 runs of optimization show that the optimized value for domain size is 17 nm, while the short-circuit current vs. voltage characteristic shows a very good agreement with the experimental results obtained by previous researchers. © 2014 Springer Science+Business Media New York

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. DESIGN & METHODS: Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. RESULTS: The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. CONCLUSIONS: Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bubble characteristics such as shape, size, and trajectory control the hydrodynamics and therefore heat transfer in fluidized bed reactors. Thus understanding these characteristics is very important for the design and scaleup of fluidized beds. An earlier developed Eulerian-Eulerian two-fluid model for simulating dense gas–solid two-phase flow has been used to compare the experimental data in a pseudo-two-dimensional (2-D) bed. Bubbles are injected asymmetrically by locating the nozzle at proximity to the wall, thus presenting the effect wall has on asymmetrical injection as compared to symmetrical injection. In this work, a digital image analysis technique was developed to study the bubble behaviour in a two-dimensional bubbling bed. The high-speed photography reveals an asymmetric wake formation during detachment indicating an early onset of mixing process. The wall forces acts tangentially on thebubble and has a significant impact on the bubble shape, neck formation during detachment and its trajectory through the bed. Larger bubbles drifting away from the centre with longer paths are observed. This qualitative behaviour is well predicted by CFD modelling. Asymmetric injection can significantly influence the heat and mass transfer characteristics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new robust nonlinear excitationcontroller design for synchronous generators in multimachine powersystems to enhance the transient stability. The mismatches betweenthe original power system model and formulated mathematical modelare considered as uncertainties which are modeled through thesatisfaction of matching conditions. The exogenous noises appearingfrom measurements are incorporated with the power system modelincluding the two-axis model of synchronous generators. The partialfeedback linearization technique is used to design the controller whichtransforms the original nonlinear multimachine power system modelinto several reduced-order linear and autonomous subsystems. Thedesired control law is obtained for each subsystem and implemented ina decentralized manner provided that the dynamics of the autonomoussubsystems have no effects on the overall stability of the system. Theanalysis related to the dynamics of noisy autonomous subsystems isalso included and the proposed controller has the excellent capabilityto decouple these noises. Finally, the performance of the proposedcontrol scheme is evaluated on an IEEE 39-bus benchmark powersystem following different types of large disturbances. The performanceof the proposed controller is compared to that of a partialfeedback linearizing controller, which is designed without robustnessproperties, to verify the effectiveness of the proposed control scheme.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In-silico optimised two-dimensional high performance liquid chromatographic (2D-HPLC) separations of a model methamphetamine seizure sample are described, where an excellent match between simulated and real separations was observed. Targeted separation of model compounds was completed with significantly reduced method development time. This separation was completed in the heart-cutting mode of 2D-HPLC where C18 columns were used in both dimensions taking advantage of the selectivity difference of methanol and acetonitrile as the mobile phases. This method development protocol is most significant when optimising the separation of chemically similar chemical compounds as it eliminates potentially hours of trial and error injections to identify the optimised experimental conditions. After only four screening injections the gradient profile for both 2D-HPLC dimensions could be optimised via simulations, ensuring the baseline resolution of diastereomers (ephedrine and pseudoephedrine) in 9.7 min. Depending on which diastereomer is present the potential synthetic pathway can be categorized.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The selection of two high performance liquid chromatography (HPLC) columns with vastly different retention mechanisms is vital for performing effective two-dimensional (2D-) HPLC. This paper reports on a systematic method to select a pair of HPLC columns that provide the most different separations for a given sample. This was completed with the aid of a HPLC simulator that predicted retention profiles on the basis of real experimental data, which is difficult when the contents of sample matrices are largely-or completely-unknown. Peaks from the same compounds must first be matched between chromatograms to compare the retention profiles and optimised 2D-HPLC column selection. In this work, two methods of matching peaks between chromatograms were explored and an optimal pair of chromatography columns was selected for 2D-HPLC. First, a series of 17 antioxidants were selected as an analogue for a coffee extract. The predicted orthogonality of the standards was 39%, according to the fractional surface coverage 'bins' method, which was close to the actual space utilisation of the standard mixture, 44%. Moreover, the orthogonality for the 2D-HPLC of coffee matched the predicted value of 38%. The second method employed a complex sample matrix of urine to optimise the column selections. Seven peaks were confidently matched between chromatograms by comparing relative peak areas of two detection strategies: UV absorbance and potassium permanganate chemiluminescence. It was found that the optimal combinations had an orthogonality of 35% while the actual value was closer to 30%.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Routine agricultural practices are heavily dependent on the use of surfactants, many of which are toxic to humans and detrimental to the environment. In proof of concept work we have previously shown the potential of nanostructured liquid crystalline particles (NLCP) to safely interact with plant leaf cuticular surfaces with minimal impact on epicuticular waxes. Here we demonstrate the use of NLCP to effectively deliver the auxin herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) to plant leaves in laboratory and field studies. In the laboratory, the physiological stress responses of lupin, Lupinus angustifolius (L.) (Fabaceae) towards NLCP spray applications were shown to be much reduced in comparison with application of two common surfactants. Phytotoxicity assays of 2,4-D loaded NLCP were used to validate the herbicidal effects on Arabidopsis thaliana (L.) Heynth. (Brassicaceae) and established a similarity with that of surfactant assisted 2,4-D delivery when tested at a concentration of 0.1%. Field trials were conducted to test the efficacy of NLCP-assisted delivery of 2,4-D in comparison with commercial surfactants for the control of the invasive weed wild radish, Raphanus raphanistrum (L.) (Brassicaceae), in wheat, Triticum aestivum (L.) (Poaceae) crop fields. Compared against Estercide 800, a commercially available 2,4-D formulation, NLCP assisted delivery of 2,4-D was effective at low concentrations of 0.03% and 0.06%. The crop yield remained similar for all the tested concentrations and formulations of 2,4-D loaded NLCP and Estercide 800. This is the first report to directly show that, as an alternative to conventional methods, NLCP can be used under both laboratory and field conditions to successfully delivery an agrochemical.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In-silico optimisation of a two-dimensional high performance liquid chromatography (2D-HPLC) separation protocol has been developed for the interogation of methamphetamine samples including model, real world seizure, and laboratory synthesised samples. The protocol used Drylab® software to rapidly identify the optimum separation conditions from a library of chromatography columns. The optimum separation space was provided by the Phenomonex Kinetex PFP column (first dimension) and an Agilent Poroshell 120 EC-C18 column (second dimension). To facilitate a rapid 2D-HPLC analysis the particle packed C18 column was replaced with a Phenomenex Onyx Monolithic C18 withought sacrificing separation performance. The Drylab® optimised and experimental separations matched very closely, highlighting the robust nature of HPLC simulations. The chemical information gained from an intermediate methamphetamine sample was significant and complimented that generated from a pure seizure sample. The influence of the two-dimensional separation on the analytical figures of merit was also investigated. The limits of detection for key analytes in the second dimension determined for methamphetamine (4.59 × 10-⁴ M), pseudoephedrine (4.03 × 10-4 M), caffeine (5.16 × 10-⁴ M), aspirin (9.32 × 10-4 M), paracetamol (5.93 × 10-4 M) and procaine (2.02 × 10-3 M).