192 resultados para Apertureless aplanatic lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Migration, Citizenship and Intercultural Relations reflects on the tensions and contradictions that arise within debates on social inclusion, arguing that both the concept of social inclusion and policy surrounding it need to incorporate visions of citizenship that value ethnic diversity. Presenting the latest empirical research from Australia and engaging with contemporary global debates on questions of identity, citizenship, intercultural relations and social inclusion, this book unsettles fixed assumptions about who is included as a valued citizen and explores the possibilities for engendering inclusive visions of citizenship in local, national and transnational spaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Business Intelligence is becoming more pervasive in many large and medium-sized organisations. Being a long term undertaking Business Intelligence raises many issues that an organisation has to deal with in order to improve its decision making processes. Data quality is one of the main issues exposed by Business Intelligence. Within the organisation data quality can affect attitudes to Business Intelligence itself, especially from the business users group. Comprehensive management of data quality is a crucial part of any Business Intelligence endeavour. It is important to address all types of data quality issues and come up with an all-in-one solution. We believe that extensive metadata infrastructure is the primary technical solution for management of data quality in Business Intelligence. Moreover, metadata has a more broad application for improving the Business Intelligence environment. Upon identifying the sources of data quality issues in Business Intelligence we propose a concept of data quality management by means of metadata framework and discuss the recommended solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Despite declining rates of cardiovascular disease (CVD) mortality in developed countries, lower socioeconomic groups continue to experience a greater burden of the disease. There are now many evidence-based treatments and prevention strategies for the management of CVD and it is essential that their impact on the more disadvantaged group is understood if socioeconomic inequalities in CVD are to be reduced.

Aims To determine whether key interventions for CVD prevention and treatment are effective among lower socioeconomic groups, to describe barriers to their effectiveness and the potential or actual impact of these interventions on the socioeconomic gradient in CVD.

Methods Interventions were selected from four stages of the CVD continuum. These included smoking reduction strategies, absolute risk assessment, cardiac rehabilitation, secondary prevention medications, and heart failure self-management programmes. Electronic searches were conducted using terms for each intervention combined with terms for socioeconomic status (SES).

Results Only limited evidence was found for the effectiveness of the selected interventions among lower SES groups and there was little exploration of socioeconomic-related barriers to their uptake. Some broad themes and key messages were identified. In the majority of findings examined, it was clear that the underlying material, social and environmental factors associated with disadvantage are a significant barrier to the effectiveness of interventions.

Conclusion Opportunities to reduce socioeconomic inequalities occur at all stages of the CVD continuum. Despite this, current treatment and prevention strategies may be contributing to the widening socioeconomic-CVD gradient. Further research into the impact of best-practice interventions for CVD upon lower SES groups is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This prospective study was designed to subjectively and objectively evaluate the performance of an aspheric multifocal back surface rigid gas permeable (RGP) contact lens. The multifocal element of this lens design consisted of an aspheric optical zone that varied according to the patient's ametropia, corneal topography, and required reading addition.

Methods: We fit 28 presbyopic subjects with an aspheric multifocal back surface RGP contact lens (age range: 45 to 68 years). Reading additions ranged from +0.75 D to +2.50 D. Subjects were assessed initially and at 2, 6, and 12 weeks for ocular changes, visual performance, and subjective responses.

Results: We required 116 RGP lenses to achieve an acceptable fit and visual acuity in 28 subjects (55 eyes). At the final visit, the distance logMAR acuity with the multifocal contact lens (+0.12 +/-0.10) was not statistically different (t=-0.623, P= 0.5388) from spectacle acuity at the initial visit (+0.10 +/-0.12). The near logMAR acuity with the multifocal contact lens at the final visit (0.36 +/- 0.12) was not statistically different from that for near acuity with spectacles at the initial visit (0.33 +/- 0.13). No slit lamp signs worsened during the study. A reduction in myopia of 0.67 D was noted by the final visit. Spectacle blur was noted if the acuity at the initial refraction was compared to the acuity with the same refraction at the final visit (t= -3.287, P= 0.0028) but not when the refractive changes were incorporated (t= 1.058, P= 0.3127). All subjects rated the performance of the lenses very highly: comfort, 86%; distance acuity, 83%; near acuity, 73%; and stability of vision, 74%. Twenty-four subjects (86%) chose the multifocal contact lens as their preference.

Conclusion: We demonstrated that a multifocal design is able to provide acceptable distance and near correction for presbyopic patients. The aspheric geometry required can be optimized for a given patient by considering his/her degree of ametropia, as well as the corneal topography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:  The aim was to determine world-wide patterns of fitting contact lenses for the correction of presbyopia.

Methods:  Up to 1,000 survey forms were sent to contact lens fitters in each of 38 countries between January and March every year over five consecutive years (2005 to 2009). Practitioners were asked to record data relating to the first 10 contact lens fittings or refittings performed after receiving the survey form.

Results:  Data were received relating to 16,680 presbyopic (age 45 years or older) and 84,202 pre-presbyopic (15 to 44 years) contact lens wearers. Females are over-represented in presbyopic versus pre-presbyopic groups, possibly reflecting a stronger desire for the cosmetic benefits of contact lenses among older women. The extent to which multifocal and monovision lenses are prescribed for presbyopes varies considerably among nations, ranging from 79 per cent of all soft lenses in Portugal to zero in Singapore. There appears to be significant under-prescribing of contact lenses for the correction of presbyopia, although for those who do receive such corrections, three times more multifocal lenses are fitted compared with monovision fittings. Presbyopic corrections are most frequently prescribed for full-time wear and monthly replacement.

Conclusions:  Despite apparent improvements in multifocal design and an increase in available multifocal options in recent years, practitioners are still under-prescribing with respect to the provision of appropriate contact lenses for the correction of presbyopia. Training of contact lens practitioners in presbyopic contact lens fitting should be accelerated and clinical and laboratory research in this field should be intensified to enhance the prospects of meeting the needs of presbyopic contact lens wearers more fully.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:  The aim was to document contact lens prescribing trends in Australia between 2000 and 2009.

Methods:  A survey of contact lens prescribing trends was conducted each year between 2000 and 2009. Australian optometrists were asked to provide information relating to 10 consecutive contact lens fittings between January and March each year.

Results:  Over the 10-year survey period, 1,462 practitioners returned survey forms representing a total of 13,721 contact lens fittings. The mean age (± SD) of lens wearers was 33.2 ± 13.6 years and 65 per cent were female. Between 2006 and 2009, rigid lens new fittings decreased from 18 to one per cent. Low water content lenses reduced from 11.5 to 3.2 per cent of soft lens fittings between 2000 and 2008. Between 2005 and 2009, toric lenses and multifocal lenses represented 26 and eight per cent, respectively, of all soft lenses fitted. Daily disposable, one- to two-week replacement and monthly replacement lenses accounted for 11.6, 30.0 and 46.5 per cent of all soft lens fittings over the survey period, respectively. The proportion of new soft fittings and refittings prescribed as extended wear has generally declined throughout the past decade. Multi-purpose lens care solutions dominate the market. Rigid lenses and monthly replacement soft lenses are predominantly worn on a full-time basis, whereas daily disposable soft lenses are mainly worn part-time.

Conclusions:  This survey indicates that technological advances, such as the development of new lens materials, manufacturing methods and lens designs, and the availability of various lens replacement options, have had a significant impact on the contact lens market during the first decade of the 21st Century.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study was conducted to ascertain current preferences for contact lens prescribing in the Australian states and territories.

Methods: One thousand questionnaires were randomly distributed to proportionate samples of optometrists in each state of Australia. We requested details of the first 10 patients fitted with contact lenses after receipt of the questionnaire.

Results: One hundred and seventy-eight completed questionnaires were returned, detailing contact lens fits to 1,611 patients. The mean age of the patient group was 32.1 $pL 13.0 yrs (65 per cent female). For Australia as a whole: 53 per cent of patients were existing wearers, the remainder were new fits; 93 per cent of new fits were with soft lenses, of which seven per cent were for extended wear. Of the refits, 89 per cent were soft lenses and 18 per cent for extended wear. The lens material of first choice was mid-water-content (62 per cent of all soft lens fits). Only eight per cent of all soft fits were for lenses that were not replaced on a planned basis, with two weeks being the replacement interval of choice in all states and territories. The majority of rigid lenses were prescribed using mid-Dk materials (50 per cent). Analysis of solution prescribing indicates that multi-purpose products were the most common regimens for planned replacement soft lenses. The percentage of hydrogen peroxide prescribed increased as lens replacement became less frequent. By state or territory: practitioners in Tasmania prescribed more extended wear than those in any other state (p = 0.007) and practitioners in Queensland prescribed more daily disposable contact lenses than those in any other state (p = 0.009).

Conclusions: Non-planned replacement lenses are now rarely prescribed to patients. Extended-wear lenses and rigid lenses continue to be prescribed more to existing contact lens wearers than to new patients. The impact of soft multifocal lens designs on contact lens prescribing is very small, ranging from 2.6 per cent in Queensland to 4.7 per cent in Victoria, despite 20 per cent of patients being more than 45 years of age.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of rigid materials with high oxygen permeability (Dk) is on the increase, their major benefit being the reduction of hypoxia. However, there is a reluctance to use these materials possibly due to increased surface scratching, reduced wettability, increased deposition, reduced life expectancy and parameter instability. Considering parameter stability, various studies have demonstrated contradictory results or used high Dk materials based on the silicone acrylate polymer. This study was designed to investigate whether the parameters of a high Dk rigid fluorocarbon contact lens material changed during daily wear and extended wear schedules. Thirty five subjects, divided into group groups, Group I wore the lens on a daily wear basis, whereas those in Group II wore the lens on a monthly extended wear basis. The parameters and integrity of the lenses were monitored in both groups every 3 months. For lens integrity a statistically significant increase in surface scratching was demonstrated for the lenses worn by the subjects of both groups over the time of the study (Group I, F=7.990, P <0.0001 [ANCOVA]; Group II, F=6.241, P=0.003 [ANCOVA]). The only parameter to show a statistically significant variation over the study period was that of centre thickness for the lenses worn by the subjects in Group I (F=3.976, P=0.0063 [ANCOVA]), with a mean reduction in centre thickness of 0.022 mm at the 12 month visit.

No change was noted for either group or between groups for the other parameters measured. This study demonstrates that the parameters of rigid contact lenses manufactured from high Dk fluorocarbons are stable with only a non-clinically significant reduction in centre thickness for the contact lenses worn by the subjects in Group I.