206 resultados para Dental contact lens


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives. To investigate initial comfort and adaptation of currently successful low oxygen transmissibility soft lens wearers refitted with silicone hydrogel (SH) lenses for daily wear.

Methods. Fifty-five subjects were enrolled in a subject-masked 5-month clinical trial in which they wore 5 SH lenses in a randomized, crossover design. Comfort, burning, and dryness were rated on scales of 0 to 100 immediately on insertion and the time for lens settling was recorded. Symptoms were then rated at various times, using BlackBerry wireless communication devices (Research in Motion, Waterloo, Canada), during the day for 2 cycles of 2 weeks wear for each lens type.

Results. Comfort immediately on insertion varied between lens types (P=0.002). All lens types were reported by the subjects to have settled within 30 to 45 sec of insertion (P=0.14) and settled comfort was greater than comfort immediately on insertion (P<0.001). Comfort within the first hour of wear also varied between lens types (P=0.02). Comfort during the day decreased significantly for all lenses (P=0.001), but there was no difference between lenses (P=0.19) and no effect of lens age (P=0.15). The wearing times were greater with the SH lenses than the habitual lenses worn before study commencement (P=0.001). Overall performance of the lenses after 4 weeks was high, with no difference between lenses (P=0.45).

Conclusions. Initial comfort and adaptation to all SH lenses were good and no differences in the overall ratings were found between the 5 SH lenses investigated. Decreased comfort was noted later in the day with all lens types, but longer wearing times were reported with the SH lenses than previous hydroxyethyl methacrylate-based lenses.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. Various methods have been used in clinical trials to collect time-sensitive subjective responses, including study diaries, telephone interviews, and use of text messaging. However, all of these methods are limited by the uncertainty of when the participants enrolled in the study actually record their responses. This technical note reports on the utility of the BlackBerry smartphone to collect such data and why such a system provides advantages over other methods to report subjective ratings in clinical studies.

Methods. The Centre for Contact Lens Research developed an on-line web-enabled system that permits participants to record and immediately transmit subjective rating scores in numerical form directly into a web-enabled database. This, combined with the utility of BlackBerrys, enabled time-specific e-mail requests to be sent to the study participants and then for that data to be simultaneously transmitted to the web-enabled database. This system has been used in several clinical trials conducted at the Centre for Contact Lens Research, in which data were collected at various times and in several specific locations or environments.

Results. In the clinical trials conducted using this system, participants provided responses on 97.5% of occasions to the requests for data generated by the automated system. When the request was for data on a set date, this method resulted in responses of 84.1% of the time.

Conclusions. The series of clinical trials reported here show the benefits of the utilization of the BlackBerry to collect time- or environment-sensitive data via a web-enabled system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. To investigate whether the inclusion of a rub and rinse step before contact lens disinfection has an impact on solution-induced corneal staining.

Methods. This was a prospective, double-masked, single investigator study. Twenty participants were recruited for two visits, where balafilcon-A lenses were worn bilaterally for 2 h. Each pair of lenses was prepared using two different methodologies. The “control” lens was transferred from the blister pack directly into a storage case containing polyhexamethylene biguanide-based lens care solution. The contralateral “test” lens was rubbed and simultaneously rinsed using the same polyhexamethylene biguanide-based care solution, for either 60 s (visit 1) or 20 s (visit 2). Both lenses were then soaked in the solution overnight. After baseline corneal staining assessments, the lenses were inserted following a randomized contralateral model. After 2 h, lenses were removed, corneal staining was regraded, and comfort scores were obtained.

Results. Rubbed and rinsed test lenses induced significantly less corneal staining than control lenses for all participants during visit 1 (mean ± SD: 516 ± 843 vs. 2170 ± 902; p < 0.001) and visit 2 (522 ± 417 vs. 2091 ± 965; p < 0.001). There was no significant difference between the test lenses during visits 1 and 2 (p = 0.72) or controls (p = 0.50). Comfort scores did not differ between eyes (p > 0.05).

Conclusions. Corneal staining induced after 2 h of lens wear with the combination of balafilcon-A and polyhexamethylene biguanide-based lens care solution can be significantly reduced by including a rub and rinse step before overnight soaking. Further work is required to establish the longevity of this effect during the monthly wearing cycle.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. The purposes of the study were to investigate the test-retest reliability and the validity of new versions of the Melbourne Edge Test (MET) and the High/Low Contrast Visual Acuity (H/LCVA) chart and to investigate the agreement between the original and new versions.

Methods. The MET original photographic version, MET new light box version, H/LCVA Chart original photographic version, H/LCVA Chart new printed version, and the Pelli-Robson chart were administered twice to one eye of 22 subjects with low vision and 20 soft contact lenses wearers.

Results. For the low vision group, the test-retest 95% limits of agreement were ±5.2 dB for the MET new light box version and ±0.39 logarithm of the minimum angle of resolution (logMAR) for the LCVA component of the H/LCVA new printed version. For the soft contact lens group, the test-retest 95% limits of agreement were ±2.1 dB for the MET new light box version and ± 0.26 logMAR for the LCVA component of the H/LCVA new printed version. Moderate to high correlations were obtained between contrast sensitivity tests, thus providing evidence of validity. Scores obtained for the new test versions were significantly higher than the original versions (p < 0.01).

Conclusions. Of all the tests administered, the MET original photographic version and the Pelli-Robson Chart had the highest test-retest reliability for the low vision group. For the soft contact lens group, the H/LCVA original version (low contrast letters, 18% Weber) and the Pelli-Robson Chart had the highest reliability.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The recent launch of the Air Optix Aqua Multifocal lens (Ciba Vision) means that there are three silicone hydrogel (SiHy) multifocal lenses available. The benefits of SiHy materials have been well documented (Dumbleton, 2006), but until recently they weren't available in multifocal designs. With an aging population, it's likely that a large number of contact lens wearers are approaching presbyopia, which will result in a dramatic increase in demand for multifocal lenses.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Microbial infections of the cornea frequently cause painful, blinding and debilitating disease that is often difficult to treat and may require corneal transplantation. In addition, sterile corneal infiltrates that are associated with contact lens wear cause pain, visual impairment and photophobia. In this article, we review the role of Toll-Like Receptors (TLR) in bacterial keratitis and sterile corneal infiltrates, and describe the role of MD-2 regulation in LPS responsiveness by corneal epithelial cells. We conclude that both live bacteria and bacterial products activate Toll-Like Receptors in the cornea, which leads to chemokine production and neutrophil recruitment to the corneal stroma. While neutrophils are essential for bacterial killing, they also cause tissue damage that results in loss of corneal clarity. These disparate outcomes, therefore, represent a spectrum of disease severity based on this pathway, and further indicate that targeting the TLR pathway is a feasible approach to treating inflammation caused by live bacteria and microbial products. Further, as the P. aeruginosa type III secretion system (T3SS) also plays a critical role in disease pathogenesis by inducing neutrophil apoptosis and facilitating bacterial growth in the cornea, T3SS exotoxins are additional targets for therapy for P. aeruginosa keratitis.