11 resultados para user tests
em Dalarna University College Electronic Archive
Resumo:
This project is based on Artificial Intelligence (A.I) and Digital Image processing (I.P) for automatic condition monitoring of sleepers in the railway track. Rail inspection is a very important task in railway maintenance for traffic safety issues and in preventing dangerous situations. Monitoring railway track infrastructure is an important aspect in which the periodical inspection of rail rolling plane is required.Up to the present days the inspection of the railroad is operated manually by trained personnel. A human operator walks along the railway track searching for sleeper anomalies. This monitoring way is not more acceptable for its slowness and subjectivity. Hence, it is desired to automate such intuitive human skills for the development of more robust and reliable testing methods. Images of wooden sleepers have been used as data for my project. The aim of this project is to present a vision based technique for inspecting railway sleepers (wooden planks under the railway track) by automatic interpretation of Non Destructive Test (NDT) data using A.I. techniques in determining the results of inspection.
Resumo:
This Thesis project is a part of the research conducted in Solar industry. ABSOLICON Solar Concentrator AB has invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate distribution of density of solar radiation in the focal line of the concentrated parabolic reflectors and to measure radiation from the artificial source of light being a calibration-testing tool.On the basis of the requirements of the company’s administration and needs of designing the concentrated reflectors the operation conditions for the Sun-Walker were formulated. As the first step, the complex design of the whole system was made and division on the parts was specified. After the preliminary conducted simulation of the functions and operation conditions of the all parts were formulated.As the next steps, the detailed design of all the parts was made. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Sun-Walker were assembled and tested. The software part, which controls the Sun-Walker work and conducts measurements of solar irradiation, was created on the LabVIEW basis. To tune and test the software part, the special simulator was designed and assembled.When all parts were assembled in the complete system, the Sun-Walker was tested, calibrated and tuned.
Resumo:
Many companies implement a modular architecture to support the need to create more variants with less effort. Although the modular architecture has many benefits, the tests to detect any defects become a major challenge. However, a modular architecture with defined functional elements seems beneficial to test at module level, so called MPV (Module Property Verification). This paper presents studies from 29 companies with the purpose of showing trends in the occurrence of defects and how these can support the MPV.
Resumo:
Background and aims Evaluating status in patients with motor fluctuations is complex and occasional observations/measurements do not give an adequate picture as to the time spent in different states. We developed a test battery to assess advanced Parkinson patients' status consisting of diary assessments and motor tests. This battery was constructed and implemented on a handheld computer with built-in mobile communication. In fluctuating patients, it should typically be used several times daily in the home environment, over periods of about one week. The aim of this battery is to provide status information in order to evaluate treatment effects in clinical practice and research, follow up treatments and disease progression and predict outcome to optimize treatment strategy. Methods Selection of diary questions was based on a previous study with Duodopa® (DIREQT). Tapping tests (with and without visual cueing) and a spiral drawing test were added. Rapid prototyping was used in development of the user interface. An evaluation with two pilot patients was performed before and after receiving new treatments for advanced disease (one received Duodopa® and one received DBS). Speed and proportion missed taps were calculated for the tapping tests and entropy of the radial drawing velocity was calculated for the spiral tests. Test variables were evaluated using non-parametric statistics. Results Post-treatment improvement was detected in both patients in many of the test variables. Conclusions Although validation work remains, preliminary results are promising and the test battery is currently being evaluated in a long-term health economics study with Duodopa® (DAPHNE).
Resumo:
Background: A test battery consisting of self-assessments and motor tests (tapping and spiral drawing) was developed for a hand computer with touch screen in a telemedicine setting. Objectives: To develop and evaluate a web-based system that delivers decision support information to the treating clinical staff for assessing PD symptoms in their patients based on the test battery data. Methods: The test battery is currently being used in a clinical trial (DAPHNE, EudraCT No. 2005-002654-21) by sixty five patients with advanced Parkinson’s disease (PD) on 9991 test occasions (four tests per day during in all 362 week-long test periods) at nine clinics around Sweden. Test results are sent continuously from the hand unit over a mobile net to a central computer and processed with statistical methods. They are summarized into scores for different dimensions of the symptom state and an ‘overall test score’ reflecting the overall condition of the patient during a test period. The information in the web application is organized and presented graphically in a way that the general overview of the patient performance per test period is emphasized. Focus is on the overall test score, symptom dimensions and daily summaries. In a recent preliminary user evaluation, the web application was demonstrated to the fifteen study nurses who had used the test battery in the clinical trial. At least one patient per clinic was shown. Results: In general, the responses from nurses were positive. They claimed that the test results shown in the system were consistent with their own clinical observations. They could follow complications, changes and trends within their patients. Discussion: In conclusion, the system is able to summarise the various time series of motor test results and self-assessments during test periods and present them in a useful manner. Its main contribution is a novel and reliable way to capture and easily access symptom information from patients’ home environment. The convenient access to current symptom profile as well as symptom history provides a basis for individualized evaluation and adjustment of treatments.
Resumo:
Objective: To investigate whether advanced visualizations of spirography-based objective measures are useful in differentiating drug-related motor dysfunctions between Off and dyskinesia in Parkinson’s disease (PD). Background: During the course of a 3 year longitudinal clinical study, in total 65 patients (43 males and 22 females with mean age of 65) with advanced PD and 10 healthy elderly (HE) subjects (5 males and 5 females with mean age of 61) were assessed. Both patients and HE subjects performed repeated and time-stamped assessments of their objective health indicators using a test battery implemented on a telemetry touch screen handheld computer, in their home environment settings. Among other tasks, the subjects were asked to trace a pre-drawn Archimedes spiral using the dominant hand and repeat the test three times per test occasion. Methods: A web-based framework was developed to enable a visual exploration of relevant spirography-based kinematic features by clinicians so they can in turn evaluate the motor states of the patients i.e. Off and dyskinesia. The system uses different visualization techniques such as time series plots, animation, and interaction and organizes them into different views to aid clinicians in measuring spatial and time-dependent irregularities that could be associated with the motor states. Along with the animation view, the system displays two time series plots for representing drawing speed (blue line) and displacement from ideal trajectory (orange line). The views are coordinated and linked i.e. user interactions in one of the views will be reflected in other views. For instance, when the user points in one of the pixels in the spiral view, the circle size of the underlying pixel increases and a vertical line appears in the time series views to depict the corresponding position. In addition, in order to enable clinicians to observe erratic movements more clearly and thus improve the detection of irregularities, the system displays a color-map which gives an idea of the longevity of the spirography task. Figure 2 shows single randomly selected spirals drawn by a: A) patient who experienced dyskinesias, B) HE subject, and C) patient in Off state. Results: According to a domain expert (DN), the spirals drawn in the Off and dyskinesia motor states are characterized by different spatial and time features. For instance, the spiral shown in Fig. 2A was drawn by a patient who showed symptoms of dyskinesia; the drawing speed was relatively high (cf. blue-colored time series plot and the short timestamp scale in the x axis) and the spatial displacement was high (cf. orange-colored time series plot) associated with smooth deviations as a result of uncontrollable movements. The patient also exhibited low amount of hesitation which could be reflected both in the animation of the spiral as well as time series plots. In contrast, the patient who was in the Off state exhibited different kinematic features, as shown in Fig. 2C. In the case of spirals drawn by a HE subject, there was a great precision during the drawing process as well as unchanging levels of time-dependent features over the test trial, as seen in Fig. 2B. Conclusions: Visualizing spirography-based objective measures enables identification of trends and patterns of drug-related motor dysfunctions at the patient’s individual level. Dynamic access of visualized motor tests may be useful during the evaluation of drug-related complications such as under- and over-medications, providing decision support to clinicians during evaluation of treatment effects as well as improve the quality of life of patients and their caregivers. In future, we plan to evaluate the proposed approach by assessing within- and between-clinician variability in ratings in order to determine its actual usefulness and then use these ratings as target outcomes in supervised machine learning, similarly as it was previously done in the study performed by Memedi et al. (2013).
Resumo:
Objective To investigate if a home environment test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression. Background Seventy-seven patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study at 10 clinics in Sweden and Norway; 40 of them were treated with levodopa-carbidopa intestinal gel (LCIG) and 37 patients were candidates for switching from oral PD treatment to LCIG. They utilized a mobile device test battery, consisting of self-assessments of symptoms and objective measures of motor function through a set of fine motor tests (tapping and spiral drawings), in their homes. Both the LCIG-naïve and LCIG-non-naïve patients used the test battery four times per day during week-long test periods. Methods Assessments The LCIG-naïve patients used the test battery at baseline (before LCIG), month 0 (first visit; at least 3 months after intraduodenal LCIG), and thereafter quarterly for the first year and biannually for the second and third years. The LCIG-non-naïve patients used the test battery from the first visit, i.e. month 0. Out of the 77 patients, only 65 utilized the test battery; 35 were LCIG-non-naïve and 30 LCIG-naïve. In 20 of the LCIG-naïve patients, assessments with the test battery were available during oral treatment and at least one test period after having started infusion treatment. Three LCIG-naïve patients did not use the test battery at baseline but had at least one test period of assessments thereafter. Hence, n=23 in the LCIG-naïve group. In total, symptom assessments in the full sample (including both patient groups) were collected during 379 test periods and 10079 test occasions. For 369 of these test periods, clinical assessments including UPDRS and PDQ-39 were performed in afternoons at the start of the test periods. The repeated measurements of the test battery were processed and summarized into scores representing patients’ symptom severities over a test period, using statistical methods. Six conceptual dimensions were defined; four subjectively-reported: ‘walking’, ‘satisfied’, ‘dyskinesia’, and ‘off’ and two objectively-measured: ‘tapping’ and ‘spiral’. In addition, an ‘overall test score’ (OTS) was defined to represent the global health condition of the patient during a test period. Statistical methods Change in the test battery scores over time, that is at baseline and follow-up test periods, was assessed with linear mixed-effects models with patient ID as a random effect and test period as a fixed effect of interest. The within-patient variability of OTS was assessed using intra-class correlation coefficient (ICC), for the two patient groups. Correlations between clinical rating scores and test battery scores were assessed using Spearman’s rank correlations (rho). Results In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. However, there were no significant changes in mean OTS scores of LCIG-non-naïve patients, except for worse mean OTS at month 36 (p<0.01, n=16). The mean scores of all subjectively-reported dimensions improved significantly throughout the course of the study, except ‘walking’ at month 36 (p=0.41, n=4). However, there were no significant differences in mean scores of objectively-measured dimensions between baseline and other test periods, except improved ‘tapping’ at month 6 and month 36, and ‘spiral’ at month 3 (p<0.05). The LCIG-naïve patients had a higher within-subject variability in their OTS scores (ICC=0.67) compared to LCIG-non-naïve patients (ICC=0.71). The OTS correlated adequately with total UPDRS (rho=0.59) and total PDQ-39 (rho=0.59). Conclusions In this 3-year follow-up study of advanced PD patients treated with LCIG we found that it is possible to monitor PD progression over time using a home environment test battery. The significant improvements in the mean OTS scores indicate that the test battery is able to measure functional improvement with LCIG sustained over at least 24 months.
Resumo:
This report contains a suggestion for a simple monitoring and evaluation guideline for PV-diesel hybrid systems. It offers system users a way to better understand if their system is operated in a way that will make it last for a long time. It also gives suggestions on how to act if there are signs of unfavourable use or failure. The application of the guide requires little technical equipment, but daily manual measurements. For the most part, it can be managed by pen and paper, by people with no earlier experience of power systems.The guide is structured and expressed in a way that targets PV-diesel hybrid system users with no, or limited, earlier experience of power engineering. It is less detailed in terms of motivations for certain choices and limitations, but rich in details concerning calculations, evaluation procedures and maintenance routines. A more scientific description of the guide can be found in a related journal article.
Resumo:
Background: Established in 1999, the Swedish Maternal Health Care Register (MHCR) collects data on pregnancy, birth, and the postpartum period for most pregnant women in Sweden. Antenatal care (ANC) midwives manually enter data into the Web-application that is designed for MHCR. The aim of this study was to investigate midwives? experiences, opinions and use of the MHCR. Method: A national, cross-sectional, questionnaire survey, addressing all Swedish midwives working in ANC, was conducted January to March 2012. The questionnaire included demographic data, preformed statements with six response options ranging from zero to five (0 = totally disagree and 5 = totally agree), and opportunities to add information or further clarification in the form of free text comments. Parametric and non-parametric methods and logistic regression analyses were applied, and content analysis was used for free text comments. Results: The estimated response rate was 53.1%. Most participants were positive towards the Web-application and the included variables in the MHCR. Midwives exclusively engaged in patient-related work tasks perceived the register as burdensome (70.3%) and 44.2% questioned the benefit of the register. The corresponding figures for midwives also engaged in administrative supervision were 37.8% and 18.5%, respectively. Direct electronic transfer of data from the medical records to the MHCR was emphasised as significant future improvement. In addition, the midwives suggested that new variables of interest should be included in the MHCR ? e.g., infertility, outcomes of previous pregnancy and birth, and complications of the index pregnancy. Conclusions: In general, the MHCR was valued positively, although perceived as burdensome. Direct electronic transfer of data from the medical records to the MHCR is a prioritized issue to facilitate the working situation for midwives. Finally, the data suggest that the MHCR is an underused source for operational planning and quality assessment in local ANC centres.
Resumo:
BACKGROUND: Shared decision-making (SDM) is an emergent research topic in the field of mental health care and is considered to be a central component of a recovery-oriented system. Despite the evidence suggesting the benefits of this change in the power relationship between users and practitioners, the method has not been widely implemented in clinical practice. OBJECTIVE: The objective of this study was to investigate decisional and information needs among users with mental illness as a prerequisite for the development of a decision support tool aimed at supporting SDM in community-based mental health services in Sweden. METHODS: Three semi-structured focus group interviews were conducted with 22 adult users with mental illness. The transcribed interviews were analyzed using a directed content analysis. This method was used to develop an in-depth understanding of the decisional process as well as to validate and conceptually extend Elwyn et al.'s model of SDM. RESULTS: The model Elwyn et al. have created for SDM in somatic care fits well for mental health services, both in terms of process and content. However, the results also suggest an extension of the model because decisions related to mental illness are often complex and involve a number of life domains. Issues related to social context and individual recovery point to the need for a preparation phase focused on establishing cooperation and mutual understanding as well as a clear follow-up phase that allows for feedback and adjustments to the decision-making process. CONCLUSIONS AND IMPLICATIONS FOR PRACTICE: The current study contributes to a deeper understanding of decisional and information needs among users of community-based mental health services that may reduce barriers to participation in decision-making. The results also shed light on attitudinal, relationship-based, and cognitive factors that are important to consider in adapting SDM in the mental health system.
Resumo:
A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations in Europe. The collector parameters used as input in the tool are compiled from tests according to EN12975, without any intermediate conversions. The main target group for this tool is test institutes and certification bodies that are intended to use it for conversion of collector model parameters (derived from performance tests) into a more user friendly quantity: the annual energy output. The energy output presented in the tool is expressed as kWh per collector module. A simplified treatment of performance for PVT collectors is added based on the assumption that the thermal part of the PVT collector can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations. © 2012 The Authors.