5 resultados para six minute step test
em Dalarna University College Electronic Archive
Resumo:
An international standard, ISO/DP 9459-4 has been proposed to establish a uniform standard of quality for small, factory-made solar heating systerns. In this proposal, system components are tested separatelyand total system performance is calculated using system simulations based on component model parameter values validated using the results from the component tests. Another approach is to test the whole system in operation under representative conditions, where the results can be used as a measure of the general system performance. The advantage of system testing of this form is that it is not dependent on simulations and the possible inaccuracies of the models. Its disadvantage is that it is restricted to the boundary conditions for the test. Component testing and system simulation is flexible, but requires an accurate and reliable simulation model.The heat store is a key component conceming system performance. Thus, this work focuses on the storage system consisting store, electrical auxiliary heater, heat exchangers and tempering valve. Four different storage system configurations with a volume of 750 litre were tested in an indoor system test using a six -day test sequence. A store component test and system simulation was carried out on one of the four configurations, applying the proposed standard for stores, ISO/DP 9459-4A. Three newly developed test sequences for intemalload side heat exchangers, not in the proposed ISO standard, were also carried out. The MULTIPORT store model was used for this work. This paper discusses the results of the indoor system test, the store component test, the validation of the store model parameter values and the system simulations.
Resumo:
Internet research methods in nursing science are less developed than in other sciences. We choose to present an approach to conducting nursing research on an internet-based forum. This paper presents LiLEDDA, a six-step forum-based netnographic research method for nursing science. The steps consist of: 1. Literature review and identification of the research question(s); 2. Locating the field(s) online; 3. Ethical considerations; 4. Data gathering; 5. Data analysis and interpretation; and 6. Abstractions and trustworthiness. Traditional research approaches are limiting when studying non-normative and non-mainstream life-worlds and their cultures. We argue that it is timely to develop more up-to-date research methods and study designs applicable to nursing science that reflect social developments and human living conditions that tend to be increasingly online-based.
Resumo:
Objective: To compare results from various tapping tests with diary responses in advanced PD. Background: A home environment test battery for assessing patient state in advanced PD, consisting of diary assessments and motor tests was constructed for a hand computer with touch screen and mobile communication. The diary questions: 1. walking, 2. time in off , on and dyskinetic states, 3. off at worst, 4. dyskinetic at worst, 5. cramps, and 6. satisfied with function, relate to the recent past. Question 7, self-assessment, allows seven steps from -3 ( very off ) to +3 ( very dyskinetic ) and relate to right now. Tapping tests outline: 8. Alternately tapping two fields (un-cued) with right hand 9. Same as 8 but using left hand 10. Tapping an active field (out of two) following a system-generated rhythm (increasing speed) with the dominant hand 11. Tapping an active field (out of four) that randomly changes location when tapped using the dominant hand Methods: 65 patients (currently on Duodopa, or candidates for this treatment) entered diary responses and performed tapping tests four times per day during one to six periods of seven days length. In total there were 224 test periods and 6039 test occasions. Speed for tapping test 10 was discardedand tests 8 and 9 were combined by taking means. Descriptive statistics were used to present the variation of the test variables in relation to self assessment (question 7). Pearson correlation coefficients between speed and accuracy (percent correct) in tapping tests and diary responses were calculated. Results: Mean compliance (percentage completed test occasions per test period) was 83% and the median was 93%. There were large differences in both mean tapping speed and accuracy between the different self-assessed states. Correlations between diary responses and tapping results were small (-0.2 to 0.3, negative values for off-time and dyskinetic-time that had opposite scale directions). Correlations between tapping results were all positive (0.1 to 0.6). Conclusions: The diary responses and tapping results provided different information. The low correlations can partly be explained by the fact that questions related to the past and by random variability, which could be reduced by taking means over test periods. Both tapping speed and accuracy reflect the motor function of the patient to a large extent.
Resumo:
Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes: • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results. The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are: • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions. The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab. This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.
Resumo:
BACKGROUND: The recently developed Context Assessment for Community Health (COACH) tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources, community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment) through 49 items. OBJECTIVE: The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. DESIGNS: To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test-retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC) and percent agreement) and dimensions (ICC and Bland-Altman plots). RESULTS: In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test-retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5-0.7), demonstrating that the instrument has an acceptable level of stability. CONCLUSIONS: This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify some items and to further review items with low ICC.