7 resultados para single test electron model
em Dalarna University College Electronic Archive
Resumo:
In Sweden, there are about 0.5 million single-family houses that are heated by electricity alone, and rising electricity costs force the conversion to other heating sources such as heat pumps and wood pellet heating systems. Pellet heating systems for single-family houses are currently a strongly growing market. Future lack of wood fuels is possible even in Sweden, and combining wood pellet heating with solar heating will help to save the bio-fuel resources. The objectives of this thesis are to investigate how the electrically heated single-family houses can be converted to pellet and solar heating systems, and how the annual efficiency and solar gains can be increased in such systems. The possible reduction of CO-emissions by combining pellet heating with solar heating has also been investigated. Systems with pellet stoves (both with and without a water jacket), pellet boilers and solar heating have been simulated. Different system concepts have been compared in order to investigate the most promising solutions. Modifications in system design and control strategies have been carried out in order to increase the system efficiency and the solar gains. Possibilities for increasing the solar gains have been limited to investigation of DHW-units for hot water production and the use of hot water for heating of dishwashers and washing machines via a heat exchanger instead of electricity (heat-fed appliances). Computer models of pellet stoves, boilers, DHW-units and heat-fed appliances have been developed and the parameters for the models have been identified from measurements on real components. The conformity between the models and the measurements has been checked. The systems with wood pellet stoves have been simulated in three different multi-zone buildings, simulated in detail with heat distribution through door openings between the zones. For the other simulations, either a single-zone house model or a load file has been used. Simulations were carried out for Stockholm, Sweden, but for the simulations with heat-fed machines also for Miami, USA. The foremost result of this thesis is the increased understanding of the dynamic operation of combined pellet and solar heating systems for single-family houses. The results show that electricity savings and annual system efficiency is strongly affected by the system design and the control strategy. Large reductions in pellet consumption are possible by combining pellet boilers with solar heating (a reduction larger than the solar gains if the system is properly designed). In addition, large reductions in carbon monoxide emissions are possible. To achieve these reductions it is required that the hot water production and the connection of the radiator circuit is moved to a well insulated, solar heated buffer store so that the boiler can be turned off during the periods when the solar collectors cover the heating demand. The amount of electricity replaced using systems with pellet stoves is very dependant on the house plan, the system design, if internal doors are open or closed and the comfort requirements. Proper system design and control strategies are crucial to obtain high electricity savings and high comfort with pellet stove systems. The investigated technologies for increasing the solar gains (DHW-units and heat-fed appliances) significantly increase the solar gains, but for the heat-fed appliances the market introduction is difficult due to the limited financial savings and the need for a new heat distribution system. The applications closest to market introduction could be for communal laundries and for use in sunny climates where the dominating part of the heat can be covered by solar heating. The DHW-unit is economical but competes with the internal finned-tube heat exchanger which is the totally dominating technology for hot water preparation in solar combisystems for single-family houses.
Resumo:
Det mobila operativsystemet Android är idag ett ganska dominerande operativsystem på den mobila marknaden dels på grund av sin öppenhet men också på grund av att tillgängligheten är stor i och med både billiga och dyra telefoner finns att tillgå. Men idag har Android inget fördefinierat designmönster vilket leder till att varje utvecklare får bestämma själv vad som ska användas, vilket ibland kan leda till onödigt komplex kod i applikationerna som sen blir svårtestad och svårhanterlig. Detta arbete ämnar jämföra två designmönster, Passive Model View Controller (PMVC) och Model View View-Model (MVVM), för att se vilket designmönster som blir minst komplext med hjälp av att räkna fram mätvärden med hjälp av Cyclomatic Complexity Number (CCN). Studien är gjord utifrån arbetssättet Design & Creation och ämnar bidra med: kunskap om vilket mönster man bör välja, samt om CCN kan peka ut vilka delar i en applikation som kommer att ta mer eller mindre lång tid att testa. Under studiens gång tog vi även fram skillnader på om man anväder sig av den så kallade Single Responsibilyt Principle (SRP) eller inte. Detta för att se om separerade vyer gör någon skillnad i applikationernas komplexitet. I slutändan så visar studien på att komplexiteten i små applikationer är väldigt likvärdig, men att man även på små applikationer kan se skillnad på hur komplex koden är men också att kodkomplexitet på metodnivå kan ge riktlinjer för testfall.
Resumo:
This paper studies a special class of vector smooth-transition autoregressive (VSTAR) models that contains common nonlinear features (CNFs), for which we proposed a triangular representation and developed a procedure of testing CNFs in a VSTAR model. We first test a unit root against a stable STAR process for each individual time series and then examine whether CNFs exist in the system by Lagrange Multiplier (LM) test if unit root is rejected in the first step. The LM test has standard Chi-squared asymptotic distribution. The critical values of our unit root tests and small-sample properties of the F form of our LM test are studied by Monte Carlo simulations. We illustrate how to test and model CNFs using the monthly growth of consumption and income data of United States (1985:1 to 2011:11).
Resumo:
Background: A mobile device test battery, consisting of a patient diary collection section with disease-related questions and a fine motor test section (including spiral drawing tasks), was used by 65 patients with advanced Parkinson's disease (PD)(treated with intraduodenal levodopa/carbidopa gel infusion, Duodopa®, or candidates for this treatment) on 10439 test occasions in their home environments. On each occasion, patients traced three pre-drawn Archimedes spirals using an ergonomic stylus and self-assessed their motor function on a global Treatment Response Scale (TRS) ranging from -3 = very 'off' to 0 = 'on' to +3 = very dyskinetic. The spirals were processed by a computer-based method that generates a "spiral score" representing the PD-related drawing impairment. The scale for the score was based on a modified Bain & Findley rating scale in the range from 0 = no impairment to 5 = moderate impairment to 10 = extremely severe impairment. Objective: To analyze the test battery data for the purpose to find differences in spiral drawing performance of PD patients in relation to their self-assessments of motor function. Methods: Three motor states were used in the analysis; OFF state (including moderate and very 'off'), ON state ('on') and a dyskinetic (DYS) state (moderate and very dyskinetic). In order to avoid the problem of multiple test occasions per patient, 200 random samples of single test occasions per patient were drawn. One-way analysis of variance, ANOVA, test followed by Tukey multiple comparisons test was used to test if mean values of spiral test parameters, i.e. the spiral score and drawing completion times (in seconds), were different among the three motor states. Statistical significance was set at p<0.05. To investigate changes in the spiral score over the time-of-day test sessions for the three motor states, plots of statistical summaries were inspected. Results: The mean spiral score differed significantly across the three self-assessed motor states (p<0.001, ANOVA test). Tukey post-hoc comparisons indicate that the mean spiral score (mean ± SD; [95% CI for mean]) in DYS state (5.2 ± 1.8; [5.12, 5.28]) was higher than the mean spiral score in OFF (4.3 ± 1.7; [4.22, 4.37]) and ON (4.2 ± 1.7; [4.17, 4.29]) states. The mean spiral score was also significantly different among individual TRS values of slightly 'off' (4.02 ± 1.63), 'on' (4.07 ± 1.65) and slightly dyskinetic (4.6 ± 1.71), (p<0.001). There were no differences in drawing completion times among the three motor states (p=0.509). In the OFF and ON states, patients drew slightly more impaired spirals in the afternoon whereas in the DYS state the spiral drawing performance was more impaired in the morning. Conclusion: It was found that when patients considered themselves as being dyskinetic spiral drawing was more impaired (nearly one unit change in a 0-10 scale) compared to when they considered themselves as being 'off' and 'on'. The spiral drawing at patients that self-assessed their motor state as dyskinetic was slightly more impaired in the morning hours, between 8 and 12 o'clock, a situation possibly caused by the morning dose effect.
Resumo:
Målet med detta examensarbete är att skapa en modell för svenska förhållanden,vilken kan användas för att minimera de negativa konsekvenserna avnedskärningar men även lyfta fram de positiva effekterna som en nedskärningmedför.Utifrån modellen Realistic Downsizing Preview (RDP) (Appelbaum & Donia,2001) har vi arbetat fram en egen modell över hur en nedskärningsprocess börutföras för att få ett så lyckat resultat som möjligt. Vi vill med vår modell främjade positiva effekterna utav nedskärningar och hur organisationen skall arbeta föratt uppnå dessa, på detta sätt bör de samtidigt kunna förebygga de negativaeffekterna.Vår studie är en kvalitativ litteraturundersökning där stort fokus har lagts påinsamlandet av artiklar och arbeten som behandlar ämnet Survivor Syndrome ochhur organisation bör arbeta med nedskärningar. Det insamlade materialet har sedananalyserats källkritiskt för att sedermera kunna bli en bidragen faktor vidskapandet av vår modell ”Den Svenska Nedskärningsmodellen”(SNM). Vi utfördetvå intervjuer, den ena var på SSAB och den andra var på NCC Construction.Detta gjordes efter modellen var klar för att kunna prova den praktiskt samt för attfå synpunkter. I vår modell kommer störst fokus att läggas på tre nyckelfaktorer,dessa är arbetet med utförarna, överlevarna och offren.Arbetet riktar sig till ledningen på större svenska organisationer som står inför ennedskärning.
Resumo:
Applying microeconomic theory, we develop a forecasting model for firm entry into local markets and test this model using data from the Swedish wholesale industry. The empirical analysis is based on directly estimating the profit function of wholesale firms. As in previous entry studies, profits are assumed to depend on firm- and location-specific factors,and the profit equation is estimated using panel data econometric techniques. Using the residuals from the profit equation estimations, we identify local markets in Sweden where firm profits are abnormally high given the level of all independent variables included in the profit function. From microeconomic theory, we then know that these local markets should have higher net entry than other markets, all else being equal, and we investigate this in a second step,also using a panel data econometric model. The results of estimating the net-entry equation indicate that four of five estimated models have more net entry in high-return municipalities, but the estimated parameter is only statistically significant at conventional levels in one of our estimated models.
Resumo:
A customer is presumed to gravitate to a facility by the distance to it and the attractiveness of it. However regarding the location of the facility, the presumption is that the customer opts for the shortest route to the nearest facility.This paradox was recently solved by the introduction of the gravity p-median model. The model is yet to be implemented and tested empirically. We implemented the model in an empirical problem of locating locksmiths, vehicle inspections, and retail stores ofv ehicle spare-parts, and we compared the solutions with those of the p-median model. We found the gravity p-median model to be of limited use for the problem of locating facilities as it either gives solutions similar to the p-median model, or it gives unstable solutions due to a non-concave objective function.