3 resultados para electrical and mechanical stresses
em Dalarna University College Electronic Archive
Resumo:
Sealed gas filled flat plate solar collectors will have stresses in the material since volume and pressure varies in the gas when the temperature changes. Several geometries were analyzed and it could be seen that it is possible reducing the stresses and improve the safety factor of the weakest point in the construction by using larger area and/or reducing the distance between glass and absorber and/or change width and height relationship so the tubes are getting longer. Further it could be shown that the safety factor won't always get improved with reinforcements. It is so because when an already strong part of the collector gets reinforced it will expose weaker parts for higher stresses. The finite element method was used for finding out the stresses.
Resumo:
BACKGROUND: In a previous randomised controlled trial we showed that acupuncture with a combination of manual- and electrical stimulation (EA) did not affect the level of pain, as compared with acupuncture with manual stimulation (MA) and standard care (SC), but reduced the need for other forms of pain relief, including epidural analgesia. To dismiss an under-treatment of pain in the trial, we did a long-term follow up on the recollection of labour pain and the birth experience comparing acupuncture with manual stimulation, acupuncture with combined electrical and manual stimulation with standard care. Our hypothesis was that despite the lower frequency of use of other pain relief, women who had received EA would make similar retrospective assessments of labour pain and the birth experience 2 months after birth as women who received standard care (SC) or acupuncture with manual stimulation (MA). METHODS: Secondary analyses of data collected for a randomised controlled trial conducted at two delivery wards in Sweden. A total of 303 nulliparous women with normal pregnancies were randomised to: 40 min of MA or EA, or SC without acupuncture. Questionnaires were administered the day after partus and 2 months later. RESULTS: Two months postpartum, the mean recalled pain on the visual analogue scale (SC: 70.1, MA: 69.3 and EA: 68.7) did not differ between the groups (SC vs MA: adjusted mean difference 0.8, 95 % confidence interval [CI] -6.3 to 7.9 and SC vs EA: mean difference 1.3 CI 95 % -5.5 to 8.1). Positive birth experience (SC: 54.3 %, MA: 64.6 % and EA: 61.0 %) did not differ between the groups (SC vs MA: adjusted Odds Ratio [OR] 1.8, CI 95 % 0.9 to 3.7 and SC vs EA: OR 1.4 CI 95 % 0.7 to 2.6). CONCLUSIONS: Despite the lower use of other pain relief, women who received acupuncture with the combination of manual and electrical stimulation during labour made the same retrospective assessments of labour pain and birth experience 2 months postpartum as those who received acupuncture with manual stimulation or standard care. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01197950.
Resumo:
This licentiate thesis has the main focus on evaluation of the wear of coated and uncoated polycrystalline cubic boron nitride cutting tool used in cutting operations against hardened steel. And to exam the surface finish and integrity of the work material used. Harder work material, higher cutting speed and cost reductions result in the development of harder and more wear resistance cutting tools. Although PCBN cutting tools have been used in over 30 years, little work have been done on PVD coated PCBN cutting tools. Therefore hard turning and hard milling experiments with PVD coated and uncoated cutting tools have been performed and evaluated. The coatings used in the present study are TiSiN and TiAlN. The wear scar and surface integrity have been examined with help of several different characterization techniques, for example scanning electron microscopy and Auger electron spectroscopy. The results showed that the PCBN cutting tools used displayed crater wear, flank wear and edge micro chipping. While the influence of the coating on the crater and flank wear was very small and the coating showed a high tendency to spalling. Scratch testing of coated PCBN showed that, the TiAlN coating resulted in major adhesive fractures. This displays the importance of understanding the effect of different types of lapping/grinding processes in the pre-treatment of hard and super hard substrate materials and the amount and type of damage that they can create. For the cutting tools used in turning, patches of a adhered layer, mainly consisting of FexOy were shown at both the crater and flank. And for the cutting tools used in milling a tribofilm consisting of SixOy covered the crater. A combination of tribochemical reactions, adhesive wear and mild abrasive wear is believed to control the flank and crater wear of the PCBN cutting tools. On a microscopic scale the difference phases of the PCBN cutting tool used in turning showed different wear characteristics. The machined surface of the work material showed a smooth surface with a Ra-value in the range of 100-200 nm for the turned surface and 100-150 nm for the milled surface. With increasing crater and flank wear in combination with edge chipping the machined surface becomes rougher and showed a higher Ra-value. For the cutting tools used in milling the tendency to micro edge chipping was significant higher when milling the tools steels showing a higher hard phase content and a lower heat conductivity resulting in higher mechanical and thermal stresses at the cutting edge.