Resumo:
Objective: To compare results from various tapping tests with diary responses in advanced PD. Background: A home environment test battery for assessing patient state in advanced PD, consisting of diary assessments and motor tests was constructed for a hand computer with touch screen and mobile communication. The diary questions: 1. walking, 2. time in off , on and dyskinetic states, 3. off at worst, 4. dyskinetic at worst, 5. cramps, and 6. satisfied with function, relate to the recent past. Question 7, self-assessment, allows seven steps from -3 ( very off ) to +3 ( very dyskinetic ) and relate to right now. Tapping tests outline: 8. Alternately tapping two fields (un-cued) with right hand 9. Same as 8 but using left hand 10. Tapping an active field (out of two) following a system-generated rhythm (increasing speed) with the dominant hand 11. Tapping an active field (out of four) that randomly changes location when tapped using the dominant hand Methods: 65 patients (currently on Duodopa, or candidates for this treatment) entered diary responses and performed tapping tests four times per day during one to six periods of seven days length. In total there were 224 test periods and 6039 test occasions. Speed for tapping test 10 was discardedand tests 8 and 9 were combined by taking means. Descriptive statistics were used to present the variation of the test variables in relation to self assessment (question 7). Pearson correlation coefficients between speed and accuracy (percent correct) in tapping tests and diary responses were calculated. Results: Mean compliance (percentage completed test occasions per test period) was 83% and the median was 93%. There were large differences in both mean tapping speed and accuracy between the different self-assessed states. Correlations between diary responses and tapping results were small (-0.2 to 0.3, negative values for off-time and dyskinetic-time that had opposite scale directions). Correlations between tapping results were all positive (0.1 to 0.6). Conclusions: The diary responses and tapping results provided different information. The low correlations can partly be explained by the fact that questions related to the past and by random variability, which could be reduced by taking means over test periods. Both tapping speed and accuracy reflect the motor function of the patient to a large extent.
Resumo:
Objective: To investigate whether advanced visualizations of spirography-based objective measures are useful in differentiating drug-related motor dysfunctions between Off and dyskinesia in Parkinson’s disease (PD). Background: During the course of a 3 year longitudinal clinical study, in total 65 patients (43 males and 22 females with mean age of 65) with advanced PD and 10 healthy elderly (HE) subjects (5 males and 5 females with mean age of 61) were assessed. Both patients and HE subjects performed repeated and time-stamped assessments of their objective health indicators using a test battery implemented on a telemetry touch screen handheld computer, in their home environment settings. Among other tasks, the subjects were asked to trace a pre-drawn Archimedes spiral using the dominant hand and repeat the test three times per test occasion. Methods: A web-based framework was developed to enable a visual exploration of relevant spirography-based kinematic features by clinicians so they can in turn evaluate the motor states of the patients i.e. Off and dyskinesia. The system uses different visualization techniques such as time series plots, animation, and interaction and organizes them into different views to aid clinicians in measuring spatial and time-dependent irregularities that could be associated with the motor states. Along with the animation view, the system displays two time series plots for representing drawing speed (blue line) and displacement from ideal trajectory (orange line). The views are coordinated and linked i.e. user interactions in one of the views will be reflected in other views. For instance, when the user points in one of the pixels in the spiral view, the circle size of the underlying pixel increases and a vertical line appears in the time series views to depict the corresponding position. In addition, in order to enable clinicians to observe erratic movements more clearly and thus improve the detection of irregularities, the system displays a color-map which gives an idea of the longevity of the spirography task. Figure 2 shows single randomly selected spirals drawn by a: A) patient who experienced dyskinesias, B) HE subject, and C) patient in Off state. Results: According to a domain expert (DN), the spirals drawn in the Off and dyskinesia motor states are characterized by different spatial and time features. For instance, the spiral shown in Fig. 2A was drawn by a patient who showed symptoms of dyskinesia; the drawing speed was relatively high (cf. blue-colored time series plot and the short timestamp scale in the x axis) and the spatial displacement was high (cf. orange-colored time series plot) associated with smooth deviations as a result of uncontrollable movements. The patient also exhibited low amount of hesitation which could be reflected both in the animation of the spiral as well as time series plots. In contrast, the patient who was in the Off state exhibited different kinematic features, as shown in Fig. 2C. In the case of spirals drawn by a HE subject, there was a great precision during the drawing process as well as unchanging levels of time-dependent features over the test trial, as seen in Fig. 2B. Conclusions: Visualizing spirography-based objective measures enables identification of trends and patterns of drug-related motor dysfunctions at the patient’s individual level. Dynamic access of visualized motor tests may be useful during the evaluation of drug-related complications such as under- and over-medications, providing decision support to clinicians during evaluation of treatment effects as well as improve the quality of life of patients and their caregivers. In future, we plan to evaluate the proposed approach by assessing within- and between-clinician variability in ratings in order to determine its actual usefulness and then use these ratings as target outcomes in supervised machine learning, similarly as it was previously done in the study performed by Memedi et al. (2013).
Resumo:
A challenge for the clinical management of Parkinson's disease (PD) is the large within- and between-patient variability in symptom profiles as well as the emergence of motor complications which represent a significant source of disability in patients. This thesis deals with the development and evaluation of methods and systems for supporting the management of PD by using repeated measures, consisting of subjective assessments of symptoms and objective assessments of motor function through fine motor tests (spirography and tapping), collected by means of a telemetry touch screen device. One aim of the thesis was to develop methods for objective quantification and analysis of the severity of motor impairments being represented in spiral drawings and tapping results. This was accomplished by first quantifying the digitized movement data with time series analysis and then using them in data-driven modelling for automating the process of assessment of symptom severity. The objective measures were then analysed with respect to subjective assessments of motor conditions. Another aim was to develop a method for providing comparable information content as clinical rating scales by combining subjective and objective measures into composite scores, using time series analysis and data-driven methods. The scores represent six symptom dimensions and an overall test score for reflecting the global health condition of the patient. In addition, the thesis presents the development of a web-based system for providing a visual representation of symptoms over time allowing clinicians to remotely monitor the symptom profiles of their patients. The quality of the methods was assessed by reporting different metrics of validity, reliability and sensitivity to treatment interventions and natural PD progression over time. Results from two studies demonstrated that the methods developed for the fine motor tests had good metrics indicating that they are appropriate to quantitatively and objectively assess the severity of motor impairments of PD patients. The fine motor tests captured different symptoms; spiral drawing impairment and tapping accuracy related to dyskinesias (involuntary movements) whereas tapping speed related to bradykinesia (slowness of movements). A longitudinal data analysis indicated that the six symptom dimensions and the overall test score contained important elements of information of the clinical scales and can be used to measure effects of PD treatment interventions and disease progression. A usability evaluation of the web-based system showed that the information presented in the system was comparable to qualitative clinical observations and the system was recognized as a tool that will assist in the management of patients.
Resumo:
OBJECTIVES: To develop a method for objective assessment of fine motor timing variability in Parkinson’s disease (PD) patients, using digital spiral data gathered by a touch screen device. BACKGROUND: A retrospective analysis was conducted on data from 105 subjects including65 patients with advanced PD (group A), 15 intermediate patients experiencing motor fluctuations (group I), 15 early stage patients (group S), and 10 healthy elderly subjects (HE) were examined. The subjects were asked to perform repeated upper limb motor tasks by tracing a pre-drawn Archimedes spiral as shown on the screen of the device. The spiral tracing test was performed using an ergonomic pen stylus, using dominant hand. The test was repeated three times per test occasion and the subjects were instructed to complete it within 10 seconds. Digital spiral data including stylus position (x-ycoordinates) and timestamps (milliseconds) were collected and used in subsequent analysis. The total number of observations with the test battery were as follows: Swedish group (n=10079), Italian I group (n=822), Italian S group (n = 811), and HE (n=299). METHODS: The raw spiral data were processed with three data processing methods. To quantify motor timing variability during spiral drawing tasks Approximate Entropy (APEN) method was applied on digitized spiral data. APEN is designed to capture the amount of irregularity or complexity in time series. APEN requires determination of two parameters, namely, the window size and similarity measure. In our work and after experimentation, window size was set to 4 and similarity measure to 0.2 (20% of the standard deviation of the time series). The final score obtained by APEN was normalized by total drawing completion time and used in subsequent analysis. The score generated by this method is hence on denoted APEN. In addition, two more methods were applied on digital spiral data and their scores were used in subsequent analysis. The first method was based on Digital Wavelet Transform and Principal Component Analysis and generated a score representing spiral drawing impairment. The score generated by this method is hence on denoted WAV. The second method was based on standard deviation of frequency filtered drawing velocity. The score generated by this method is hence on denoted SDDV. Linear mixed-effects (LME) models were used to evaluate mean differences of the spiral scores of the three methods across the four subject groups. Test-retest reliability of the three scores was assessed after taking mean of the three possible correlations (Spearman’s rank coefficients) between the three test trials. Internal consistency of the methods was assessed by calculating correlations between their scores. RESULTS: When comparing mean spiral scores between the four subject groups, the APEN scores were different between HE subjects and three patient groups (P=0.626 for S group with 9.9% mean value difference, P=0.089 for I group with 30.2%, and P=0.0019 for A group with 44.1%). However, there were no significant differences in mean scores of the other two methods, except for the WAV between the HE and A groups (P<0.001). WAV and SDDV were highly and significantly correlated to each other with a coefficient of 0.69. However, APEN was not correlated to neither WAV nor SDDV with coefficients of 0.11 and 0.12, respectively. Test-retest reliability coefficients of the three scores were as follows: APEN (0.9), WAV(0.83) and SD-DV (0.55). CONCLUSIONS: The results show that the digital spiral analysis-based objective APEN measure is able to significantly differentiate the healthy subjects from patients at advanced level. In contrast to the other two methods (WAV and SDDV) that are designed to quantify dyskinesias (over-medications), this method can be useful for characterizing Off symptoms in PD. The APEN was not correlated to none of the other two methods indicating that it measures a different construct of upper limb motor function in PD patients than WAV and SDDV. The APEN also had a better test-retest reliability indicating that it is more stable and consistent over time than WAV and SDDV.
Resumo:
Objective: To develop a method for objective quantification of PD motor symptoms related to Off episodes and peak dose dyskinesias, using spiral data gathered by using a touch screen telemetry device. The aim was to objectively characterize predominant motor phenotypes (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Background: A retrospective analysis was conducted on recordings from 65 patients with advanced idiopathic PD from nine different clinics in Sweden, recruited from January 2006 until August 2010. In addition to the patient group, 10 healthy elderly subjects were recruited. Upper limb movement data were collected using a touch screen telemetry device from home environments of the subjects. Measurements with the device were performed four times per day during week-long test periods. On each test occasion, the subjects were asked to trace pre-drawn Archimedean spirals, using the dominant hand. The pre-drawn spiral was shown on the screen of the device. The spiral test was repeated three times per test occasion and they were instructed to complete it within 10 seconds. The device had a sampling rate of 10Hz and measured both position and time-stamps (in milliseconds) of the pen tip. Methods: Four independent raters (FB, DH, AJ and DN) used a web interface that animated the spiral drawings and allowed them to observe different kinematic features during the drawing process and to rate task performance. Initially, a number of kinematic features were assessed including ‘impairment’, ‘speed’, ‘irregularity’ and ‘hesitation’ followed by marking the predominant motor phenotype on a 3-category scale: tremor, bradykinesia and/or choreatic dyskinesia. There were only 2 test occasions for which all the four raters either classified them as tremor or could not identify the motor phenotype. Therefore, the two main motor phenotype categories were bradykinesia and dyskinesia. ‘Impairment’ was rated on a scale from 0 (no impairment) to 10 (extremely severe) whereas ‘speed’, ‘irregularity’ and ‘hesitation’ were rated on a scale from 0 (normal) to 4 (extremely severe). The proposed data-driven method consisted of the following steps. Initially, 28 spatiotemporal features were extracted from the time series signals before being presented to a Multilayer Perceptron (MLP) classifier. The features were based on different kinematic quantities of spirals including radius, angle, speed and velocity with the aim of measuring the severity of involuntary symptoms and discriminate between PD-specific (bradykinesia) and/or treatment-induced symptoms (dyskinesia). A Principal Component Analysis was applied on the features to reduce their dimensions where 4 relevant principal components (PCs) were retained and used as inputs to the MLP classifier. Finally, the MLP classifier mapped these components to the corresponding visually assessed motor phenotype scores for automating the process of scoring the bradykinesia and dyskinesia in PD patients whilst they draw spirals using the touch screen device. For motor phenotype (bradykinesia vs. dyskinesia) classification, the stratified 10-fold cross validation technique was employed. Results: There were good agreements between the four raters when rating the individual kinematic features with intra-class correlation coefficient (ICC) of 0.88 for ‘impairment’, 0.74 for ‘speed’, 0.70 for ‘irregularity’, and moderate agreements when rating ‘hesitation’ with an ICC of 0.49. When assessing the two main motor phenotype categories (bradykinesia or dyskinesia) in animated spirals the agreements between the four raters ranged from fair to moderate. There were good correlations between mean ratings of the four raters on individual kinematic features and computed scores. The MLP classifier classified the motor phenotype that is bradykinesia or dyskinesia with an accuracy of 85% in relation to visual classifications of the four movement disorder specialists. The test-retest reliability of the four PCs across the three spiral test trials was good with Cronbach’s Alpha coefficients of 0.80, 0.82, 0.54 and 0.49, respectively. These results indicate that the computed scores are stable and consistent over time. Significant differences were found between the two groups (patients and healthy elderly subjects) in all the PCs, except for the PC3. Conclusions: The proposed method automatically assessed the severity of unwanted symptoms and could reasonably well discriminate between PD-specific and/or treatment-induced motor symptoms, in relation to visual assessments of movement disorder specialists. The objective assessments could provide a time-effect summary score that could be useful for improving decision-making during symptom evaluation of individualized treatment when the goal is to maximize functional On time for patients while minimizing their Off episodes and troublesome dyskinesias.