6 resultados para clock face drawing test

em Dalarna University College Electronic Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and aims Evaluating status in patients with motor fluctuations is complex and occasional observations/measurements do not give an adequate picture as to the time spent in different states. We developed a test battery to assess advanced Parkinson patients' status consisting of diary assessments and motor tests. This battery was constructed and implemented on a handheld computer with built-in mobile communication. In fluctuating patients, it should typically be used several times daily in the home environment, over periods of about one week. The aim of this battery is to provide status information in order to evaluate treatment effects in clinical practice and research, follow up treatments and disease progression and predict outcome to optimize treatment strategy. Methods Selection of diary questions was based on a previous study with Duodopa® (DIREQT). Tapping tests (with and without visual cueing) and a spiral drawing test were added. Rapid prototyping was used in development of the user interface. An evaluation with two pilot patients was performed before and after receiving new treatments for advanced disease (one received Duodopa® and one received DBS). Speed and proportion missed taps were calculated for the tapping tests and entropy of the radial drawing velocity was calculated for the spiral tests. Test variables were evaluated using non-parametric statistics. Results Post-treatment improvement was detected in both patients in many of the test variables. Conclusions Although validation work remains, preliminary results are promising and the test battery is currently being evaluated in a long-term health economics study with Duodopa® (DAPHNE).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To design, develop and set up a web-based system for enabling graphical visualization of upper limb motor performance (ULMP) of Parkinson’s disease (PD) patients to clinicians. Background Sixty-five patients diagnosed with advanced PD have used a test battery, implemented in a touch-screen handheld computer, in their home environment settings over the course of a 3-year clinical study. The test items consisted of objective measures of ULMP through a set of upper limb motor tests (finger to tapping and spiral drawings). For the tapping tests, patients were asked to perform alternate tapping of two buttons as fast and accurate as possible, first using the right hand and then the left hand. The test duration was 20 seconds. For the spiral drawing test, patients traced a pre-drawn Archimedes spiral using the dominant hand, and the test was repeated 3 times per test occasion. In total, the study database consisted of symptom assessments during 10079 test occasions. Methods Visualization of ULMP The web-based system is used by two neurologists for assessing the performance of PD patients during motor tests collected over the course of the said study. The system employs animations, scatter plots and time series graphs to visualize the ULMP of patients to the neurologists. The performance during spiral tests is depicted by animating the three spiral drawings, allowing the neurologists to observe real-time accelerations or hesitations and sharp changes during the actual drawing process. The tapping performance is visualized by displaying different types of graphs. Information presented included distribution of taps over the two buttons, horizontal tap distance vs. time, vertical tap distance vs. time, and tapping reaction time over the test length. Assessments Different scales are utilized by the neurologists to assess the observed impairments. For the spiral drawing performance, the neurologists rated firstly the ‘impairment’ using a 0 (no impairment) – 10 (extremely severe) scale, secondly three kinematic properties: ‘drawing speed’, ‘irregularity’ and ‘hesitation’ using a 0 (normal) – 4 (extremely severe) scale, and thirdly the probable ‘cause’ for the said impairment using 3 choices including Tremor, Bradykinesia/Rigidity and Dyskinesia. For the tapping performance, a 0 (normal) – 4 (extremely severe) scale is used for first rating four tapping properties: ‘tapping speed’, ‘accuracy’, ‘fatigue’, ‘arrhythmia’, and then the ‘global tapping severity’ (GTS). To achieve a common basis for assessment, initially one neurologist (DN) performed preliminary ratings by browsing through the database to collect and rate at least 20 samples of each GTS level and at least 33 samples of each ‘cause’ category. These preliminary ratings were then observed by the two neurologists (DN and PG) to be used as templates for rating of tests afterwards. In another track, the system randomly selected one test occasion per patient and visualized its items, that is tapping and spiral drawings, to the two neurologists. Statistical methods Inter-rater agreements were assessed using weighted Kappa coefficient. The internal consistency of properties of tapping and spiral drawing tests were assessed using Cronbach’s α test. One-way ANOVA test followed by Tukey multiple comparisons test was used to test if mean scores of properties of tapping and spiral drawing tests were different among GTS and ‘cause’ categories, respectively. Results When rating tapping graphs, inter-rater agreements (Kappa) were as follows: GTS (0.61), ‘tapping speed’ (0.89), ‘accuracy’ (0.66), ‘fatigue’ (0.57) and ‘arrhythmia’ (0.33). The poor inter-rater agreement when assessing “arrhythmia” may be as a result of observation of different things in the graphs, among the two raters. When rating animated spirals, both raters had very good agreement when assessing severity of spiral drawings, that is, ‘impairment’ (0.85) and irregularity (0.72). However, there were poor agreements between the two raters when assessing ‘cause’ (0.38) and time-information properties like ‘drawing speed’ (0.25) and ‘hesitation’ (0.21). Tapping properties, that is ‘tapping speed’, ‘accuracy’, ‘fatigue’ and ‘arrhythmia’ had satisfactory internal consistency with a Cronbach’s α coefficient of 0.77. In general, the trends of mean scores of tapping properties worsened with increasing levels of GTS. The mean scores of the four properties were significantly different to each other, only at different levels. In contrast from tapping properties, kinematic properties of spirals, that is ‘drawing speed’, ‘irregularity’ and ‘hesitation’ had a questionable consistency among them with a coefficient of 0.66. Bradykinetic spirals were associated with more impaired speed (mean = 83.7 % worse, P < 0.001) and hesitation (mean = 77.8% worse, P < 0.001), compared to dyskinetic spirals. Both these ‘cause’ categories had similar mean scores of ‘impairment’ and ‘irregularity’. Conclusions In contrast from current approaches used in clinical setting for the assessment of PD symptoms, this system enables clinicians to animate easily and realistically the ULMP of patients who at the same time are at their homes. Dynamic access of visualized motor tests may also be useful when observing and evaluating therapy-related complications such as under- and over-medications. In future, we foresee to utilize these manual ratings for developing and validating computer methods for automating the process of assessing ULMP of PD patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: A mobile device test battery, consisting of a patient diary collection section with disease-related questions and a fine motor test section (including spiral drawing tasks), was used by 65 patients with advanced Parkinson's disease (PD)(treated with intraduodenal levodopa/carbidopa gel infusion, Duodopa®, or candidates for this treatment) on 10439 test occasions in their home environments. On each occasion, patients traced three pre-drawn Archimedes spirals using an ergonomic stylus and self-assessed their motor function on a global Treatment Response Scale (TRS) ranging from -3 = very 'off' to 0 = 'on' to +3 = very dyskinetic. The spirals were processed by a computer-based method that generates a "spiral score" representing the PD-related drawing impairment. The scale for the score was based on a modified Bain & Findley rating scale in the range from 0 = no impairment to 5 = moderate impairment to 10 = extremely severe impairment. Objective: To analyze the test battery data for the purpose to find differences in spiral drawing performance of PD patients in relation to their self-assessments of motor function. Methods: Three motor states were used in the analysis; OFF state (including moderate and very 'off'), ON state ('on') and a dyskinetic (DYS) state (moderate and very dyskinetic). In order to avoid the problem of multiple test occasions per patient, 200 random samples of single test occasions per patient were drawn. One-way analysis of variance, ANOVA, test followed by Tukey multiple comparisons test was used to test if mean values of spiral test parameters, i.e. the spiral score and drawing completion times (in seconds), were different among the three motor states. Statistical significance was set at p<0.05. To investigate changes in the spiral score over the time-of-day test sessions for the three motor states, plots of statistical summaries were inspected. Results: The mean spiral score differed significantly across the three self-assessed motor states (p<0.001, ANOVA test). Tukey post-hoc comparisons indicate that the mean spiral score (mean ± SD; [95% CI for mean]) in DYS state (5.2 ± 1.8; [5.12, 5.28]) was higher than the mean spiral score in OFF (4.3 ± 1.7; [4.22, 4.37]) and ON (4.2 ± 1.7; [4.17, 4.29]) states. The mean spiral score was also significantly different among individual TRS values of slightly 'off' (4.02 ± 1.63), 'on' (4.07 ± 1.65) and slightly dyskinetic (4.6 ± 1.71), (p<0.001). There were no differences in drawing completion times among the three motor states (p=0.509). In the OFF and ON states, patients drew slightly more impaired spirals in the afternoon whereas in the DYS state the spiral drawing performance was more impaired in the morning. Conclusion: It was found that when patients considered themselves as being dyskinetic spiral drawing was more impaired (nearly one unit change in a 0-10 scale) compared to when they considered themselves as being 'off' and 'on'. The spiral drawing at patients that self-assessed their motor state as dyskinetic was slightly more impaired in the morning hours, between 8 and 12 o'clock, a situation possibly caused by the morning dose effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cemented carbide is today the most frequently used drawing die material in steel wire drawing applications. This is mainly due to the possibility to obtain a broad combination of hardness and toughness thus meeting the requirements concerning strength, crack resistance and wear resistance set by the wire drawing process. However, the increasing cost of cemented carbide in combination with the possibility to increase the wear resistance of steel through the deposition of wear resistant CVD and PVD coatings have enhanced the interest to replace cemented carbide drawing dies with CVD and PVD coated steel wire drawing dies. In the present study, the possibility to replace cemented carbide wire drawing dies with CVD and PVD coated steel drawing dies have been investigated by tribological characterisation, i.e. pin-on-disc and scratch testing, in combination with post-test observations of the tribo surfaces using scanning electron microscopy, energy dispersive X-ray spectroscopy and 3D surface profilometry. Based on the results obtained, CVD and PVD coatings aimed to provide improved tribological performance of steel wire drawing dies should display a smooth surface topography, a high wear resistance, a high fracture toughness (i.e. a high cracking and chipping resistance) and intrinsic low friction properties in contact with the wire material. Also, the steel substrate used must display a sufficient load carrying capacity and resistance to thermal softening. Of the CVD and PVD coatings evaluated in the tribological tests, a CVD TiC and a PVD CrC/C coating displayed the most promising results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A test battery consisting of self-assessments and motor tests (tapping and spiral drawing) was developed for a hand computer with touch screen in a telemedicine setting. Objectives: To develop and evaluate a web-based system that delivers decision support information to the treating clinical staff for assessing PD symptoms in their patients based on the test battery data. Methods: The test battery is currently being used in a clinical trial (DAPHNE, EudraCT No. 2005-002654-21) by sixty five patients with advanced Parkinson’s disease (PD) on 9991 test occasions (four tests per day during in all 362 week-long test periods) at nine clinics around Sweden. Test results are sent continuously from the hand unit over a mobile net to a central computer and processed with statistical methods. They are summarized into scores for different dimensions of the symptom state and an ‘overall test score’ reflecting the overall condition of the patient during a test period. The information in the web application is organized and presented graphically in a way that the general overview of the patient performance per test period is emphasized. Focus is on the overall test score, symptom dimensions and daily summaries. In a recent preliminary user evaluation, the web application was demonstrated to the fifteen study nurses who had used the test battery in the clinical trial. At least one patient per clinic was shown. Results: In general, the responses from nurses were positive. They claimed that the test results shown in the system were consistent with their own clinical observations. They could follow complications, changes and trends within their patients. Discussion: In conclusion, the system is able to summarise the various time series of motor test results and self-assessments during test periods and present them in a useful manner. Its main contribution is a novel and reliable way to capture and easily access symptom information from patients’ home environment. The convenient access to current symptom profile as well as symptom history provides a basis for individualized evaluation and adjustment of treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel test battery consisting of self-assessments and motor tests (tapping and spiral drawing) for patients with Parkinson’s disease (PD) was developed for a hand computer with touch screen in a telemedicine setting. Tests are performed four times per day in the home environment during weeklong test periods. Results are processed into scores for different dimensions of the symptom state and an ‘overall score’ reflecting the global condition of a patient during a test period. The test battery was validated in a separate study recently submitted to Mov Disord. This test battery is currently being used in an open longitudinal trial (DAPHNE, EudraCT No. 2005- 002654-21) by sixty-five patients with advanced PD at nine clinics around Sweden. On inclusion, the patients were either receiving treatment with duodenal levodopa/carbidopa infusion (Duodopa®) (n=36), or they were candidates for receiving this treatment (n=29). We now present interim results for the first twelve months. Test periods were performed in three-month intervals. During most of the periods, UPDRS ratings were performed in afternoons at the start of the week. In twenty of the patients, scores were available during individually optimized oral polypharamacy, before receiving infusion and at least one test period after having started infusion treatment. Usability and compliance with performing tests, this far are good, both with patients and clinical staff. Correlations between test periods 2 and 3 during infusion treatment (three months apart) are stronger for overall test score than for total UPDRS, indicating good reliability. The correlation between overall test score and UPDRS for all test periods is adequate (r=-0.6). In an exact Wilcoxon signed rank test, where the endpoint is the change from the first to the twelve month test period (n=25), there was no change in test results in any of the test battery dimensions for the patients already receiving infusion when included. However, in the patients entering the study before receiving infusion, there was a significant change (improvement) from the baseline to the twelve month test period in dimensions; ‘off’, ‘dyskinesia’ and ‘satisfied’ and in the ‘overall score’ (n=15). The mean improvement in overall score after infusion was 29% (p=0.015). We conclude that the test battery is able to measure a functional improvement with infusion that is sustained over at least twelve months.