5 resultados para buck converter,conducted emission,2-150kHz,DC-microgrid
em Dalarna University College Electronic Archive
Resumo:
Energy efficiency and renewable energy use are two main priorities leading to industrial sustainability nowadays according to European Steel Technology Platform (ESTP). Modernization efforts can be done by industries to improve energy consumptions of the production lines. These days, steel making industrial applications are energy and emission intensive. It was estimated that over the past years, energy consumption and corresponding CO2 generation has increased steadily reaching approximately 338.15 parts per million in august 2010 [1]. These kinds of facts and statistics have introduced a lot of room for improvement in energy efficiency for industrial applications through modernization and use of renewable energy sources such as solar Photovoltaic Systems (PV).The purpose of this thesis work is to make a preliminary design and simulation of the solar photovoltaic system which would attempt to cover the energy demand of the initial part of the pickling line hydraulic system at the SSAB steel plant. For this purpose, the energy consumptions of this hydraulic system would be studied and evaluated and a general analysis of the hydraulic and control components performance would be done which would yield a proper set of guidelines contributing towards future energy savings. The results of the energy efficiency analysis showed that the initial part of the pickling line hydraulic system worked with a low efficiency of 3.3%. Results of general analysis showed that hydraulic accumulators of 650 liter size should be used by the initial part pickling line system in combination with a one pump delivery of 100 l/min. Based on this, one PV system can deliver energy to an AC motor-pump set covering 17.6% of total energy and another PV system can supply a DC hydraulic pump substituting 26.7% of the demand. The first system used 290 m2 area of the roof and was sized as 40 kWp, the second used 109 m2 and was sized as 15.2 kWp. It was concluded that the reason for the low efficiency was the oversized design of the system. Incremental modernization efforts could help to improve the hydraulic system energy efficiency and make the design of the solar photovoltaic system realistically possible. Two types of PV systems where analyzed in the thesis work. A method was found calculating the load simulation sequence based on the energy efficiency studies to help in the PV system simulations. Hydraulic accumulators integrated into the pickling line worked as energy storage when being charged by the PV system as well.
Resumo:
Most previous studies have focused on entire trips in a geographic region, while a few of them addressed trips induced by a city landmark. Therefore paper explores trips and their CO2 emissions induced by a shopping center from a time-space perspective and their usage in relocation planning. This is conducted by the means of a case study in the city of Borlänge in mid-Sweden where trips to the city’s largest shopping mall in its center are examined. We use GPS tracking data of car trips that end and start at the shopping center. Thereafter, (1) we analyze the traffic emission patterns from a time-space perspective where temporal patterns reveal an hourly-based traffic emission dynamics and where spatial patterns uncover a heterogeneous distribution of traffic emissions in spatial areas and individual street segments. Further, (2) this study reports that most of the observed trips follow an optimal route in terms of CO2 emissions. In this respect, (3) we evaluate how well placed the current shopping center is through a comparison with two competing locations. We conclude that the two suggested locations, which are close to the current shopping center, do not show a significant improvement in term of CO2 emissions.
Resumo:
A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust ventilated buildings with warm water heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions. The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and indentify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered. The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20 % without sacrificing ventilation efficiency or thermal comfort. Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught.
Resumo:
Bakgrund: Diabetes typ 2 är en folksjukdom och kan förebyggas eller fördröjas genom hälsosamma levnadsvanor. Att informera och motivera patienterna på ett hälsofrämjande och preventivt sätt är distriktssköterskans ansvar. Distriktssköterskans nyckelroll är att kritiskt granska evidensbaserad forskning för att uppnå en säker vård av god kvalitet som kan implementeras i praktiken. Syfte: Syftet med studien var att beskriva distriktssköterskors upplevelser av att motivera patienter med diabetes typ 2 till hälsosammare levnadsvanor genom evidensbaserad vård. Metod: En kvalitativ ansats användes. Semistrukturerade intervjuer genomfördes med sju distriktssköterskor. Materialet analyserades utifrån Graneheim och Lundmans innehållsanalys. Resultat: Resultatet i föreliggande studie visar att distriktssköterskorna måste utgå från patientens situation och individanpassa informationen. Genom stöd från distriktssköterskan ska patienten kunna motivera sig själv till att genomföra förändringar. Informanterna i studien belyste vikten av att informera patienten om diabetes samt vilka komplikationer som kan uppstå. För att uppnå en patientsäker vård av hög kvalitet ansåg distriktssköterskorna att evidensbaserad kunskap var en förutsättning. Konklusion: För att motivera patienterna till förändrade levnadsvanor krävs det att distriktssköterskorna informerar och undervisar patienterna om diabetes och hur förändrade levnadsvanor påverkar hälsan. Distriktssköterskan måste finna olika metoder för att motivera patienterna. Det som förmedlas ska grunda sig på vetenskap och evidensbaserad kunskap.
Resumo:
Syfte: Att undersöka patienters upplevelser av livskvalitet vid nydiagnostiserad typ 2 Diabetes Mellitus. Metod: En empirisk studie med en kvalitativ ansats som innefattade tio deltagare med nydiagnostiserad typ 2 Diabetes Mellitus. Semistrukturerade intervjuer genomfördes utifrån en intervjuguide där insamlad data analyserades med kvalitativ manifest innehållsanalys. Resultat: Studien resulterade i fyra huvudkategorier och tio subkategorier. Upplevelsen av att få ett diagnosbesked varierade mellan deltagarna, för vissa deltagarna var beskedet inte förvånande medan andra upplevde känslor av chock och förnekelse. Deltagarna upplevde positiva förändringar, exempelvis viktnedgång och förbättrad hälsa men även negativa förändringar, exempelvis att vara beroende av läkemedel. Vissa upplevde ingen förändring alls. Typ 2 Diabetes Mellitus påverkade inte deltagarnas fysiska eller psykiska hälsa i de flesta fall. Deltagarna ansåg det som viktig att få stöd från både omgivningen och hälso- och sjukvården. Konklusion: Känslorna över ett diagnosbesked kunde variera men upplevelsen av livskvalitet påverkades inte av Typ 2 Diabetes Mellitus i de flesta fall i studien. Patientens inställning till att leva med Typ 2 Diabetes Mellitus inverkade på förmågan till att utföra egenvård, och distriktsköterskans stöd och engagemang ansågs vara betydelsefullt i sjukdomsprocessen.