9 resultados para Tsallis distribution. Solar Neutrino. TGEC
em Dalarna University College Electronic Archive
Resumo:
This Thesis project is a part of the research conducted in Solar industry. ABSOLICON Solar Concentrator AB has invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate distribution of density of solar radiation in the focal line of the concentrated parabolic reflectors and to measure radiation from the artificial source of light being a calibration-testing tool.On the basis of the requirements of the company’s administration and needs of designing the concentrated reflectors the operation conditions for the Sun-Walker were formulated. As the first step, the complex design of the whole system was made and division on the parts was specified. After the preliminary conducted simulation of the functions and operation conditions of the all parts were formulated.As the next steps, the detailed design of all the parts was made. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Sun-Walker were assembled and tested. The software part, which controls the Sun-Walker work and conducts measurements of solar irradiation, was created on the LabVIEW basis. To tune and test the software part, the special simulator was designed and assembled.When all parts were assembled in the complete system, the Sun-Walker was tested, calibrated and tuned.
Resumo:
At the beginning of 2003 the four year long research project REBUS on education, research, development and demonstration of competitive solar combisystems was launched. Research groups in Norway, Denmark, Sweden and Latvia are working together with partners from industry on innovative solutions for solar heating in the Nordic countries. Existing system concepts have been analyzed and based on the results new system designs have been developed. The proposed solutions have to fulfill country specific technical, sociological and cost requirements. Due to the similar demands on the systems in Denmark and Sweden it has been decided to develop a common system concept for both countries, which increases the market potential for the manufacturer. The focus of the development is on systems for the large number of rather well insulated existing single family houses. In close collaboration with the industrial partners a system concept has been developed that is characterized by its high compactness and flexibility. It allows the use of different types of boilers, heating distribution systems and a variable store and collector size. Two prototypes have been built, one for the Danish market with a gas boiler, and one for the Swedish market with a pellet boiler as auxiliary heater. After intensive testing and eventual further improvements at least two systems will be installed and monitored in demonstration houses. The systems have been modeled in TRNSYS and the simulation results will be used to further improve the system and evaluate the system performance.
Resumo:
In Sweden solar irradiation and space heating loads are unevenly distributed over the year. Domestic hot water loads may be nearly constant. Test results on solar collector performance are often reported as yearly output of a certain collector at fixed temperatures, e g 25, 50 and 75 C. These data are not suitable for dimensioning of solar systems, because the actual performance of the collector depends heavily on solar fraction and load distribution over the year.At higher latitudes it is difficult to attain high solar fractions for buildings, due to overheating in summer and small marginal output for added collector area. Solar collectors with internal reflectors offer possibilities to evade overheating problems and deliver more energy at seasons when the load is higher. There are methods for estimating the yearly angular irradiation distribution, but there is a lack of methods for describing the load and the storage in such a way as to enable optical design of season and load adapted collectors.This report describes two methods for estimation of solar system performance with relevance for season and load adaption. Results regarding attainable solar fractions as a function of collector features, load profiles, load levels and storage characteristics are reported. The first method uses monthly collector output data at fixed temperatures from the simulation program MINSUN for estimating solar fractions for different load profiles and load levels. The load level is defined as estimated yearly collector output at constant collector temperature divided be yearly load. This table may examplify the results:CollectorLoadLoadSolar Improvementtypeprofile levelfractionover flat plateFlat plateDHW 75 %59 %Load adaptedDHW 75 %66 %12 %Flat plateSpace heating 50 %22 %Load adaptedSpace heating 50 %28 %29 %The second method utilises simulations with one-hour timesteps for collectors connected to a simplified storage and a variable load. Collector output, optical and thermal losses, heat overproduction, load level and storage temperature are presented as functions of solar incidence angles. These data are suitable for optical design of load adapted solar collectors. Results for a Stockholm location indicate that a solar combisystem with a solar fraction around 30 % should have collectors that reduce heat production at solar heights above 30 degrees and have optimum efficiency for solar heights between 8 and 30 degrees.
Resumo:
The possibility of using solar energy during winter depends on the available solar radiation and on the geometry of the receiving surface. For high latitudes, the annual distribution of the available radiation is characterized by high asymmetry with a large amount of solar radiation from high altitude angles during the summer and a small amount of direct radiation from small altitude angles during the winter. This article deals with the origin of the difference between available solar radiation during summer and winter at high latitudes. Factors like the tilt of the earth’s axis, the eccentricity of the earth’s orbit, absorption and scattering of radiation in the atmosphere and seasonal changes in the weather conditions are discussed. Numerical examples of how these factors contribute to the reduction of the winter radiation compared to the summer radiation on surfaces with different orientation in Stockholm, latitude 59.4°N, are given. It is shown that the influence of the atmosphere and seasonal changes in the climate, and not pure earth-sun geometry, are the main reasons why it is hard to utilize solar energy at high latitudes during the winter.
Resumo:
When a stationary solar concentrator is designed, the spatial distribution of the available irradiation is of vital interest. An irradiation distribution based only on solar geometry will look similar at different sites. The only difference is that the distribution of the incident irradiation is shifted to lower solar altitudes when latitude is increased. However, real irradiation distribution will show strong asymmetry at high latitude sites, since the winter irradiation is reduced by absorption and scattering in the atmosphere, and by seasonal changes in the climate. The reduced winter irradiation at high latitudes implies that the available annual radiation is concentrated to a narrower angular interval. This means that the degree of concentration that is possible increases with latitude.In the paper examples of irradiation distribution from different sites in Europe from latitude 38°N to 65°N are shown. The origin of the reduced winter irradiation with increased latitude is discussed, and numerical examples on the performance of different types of stationary concentrators for different latitudes are given.
Resumo:
Irradiation distribution functions based on the yearly collectible energy have been derived for two locations; Sydney, Australia which represents a mid-latitude site and Stockholm, Sweden, which represents a high latitude site. The strong skewing of collectible energy toward summer solstice at high latitudes dictates optimal collector tilt angles considerably below the polar mount. The lack of winter radiation at high latitudes indicates that the optimal acceptance angle for a stationary EW-aligned concentrator decreases as latitude increases. Furthermore concentrator design should be highly asymmetric at high latitudes.
Resumo:
På uppdrag av STEM bevakade Eva Lindberg från Centrum för solenergi-forskning, SERC, Högskolan Dalarna, 20th European Photovoltaic Solar Energy Conference and Exhibition, Barcelona, 6-10 juni 2005. Ca 1700 personer fanns på deltagarlistan. På grund av konferensen omfattning kan endast ett litet urval av föredrag och utställare kommenteras i rapporten. Konferensprogrammet var indelat på följande områden:1. Grundläggande fakta, nya komponenter och material2. Kristallina kiselsolceller and materialteknologi3. Amorft och mikrokristallint kisel4. CIS, CdTe och andra (II-VI) ternära tunnfilmsceller5. PV-moduler och komponenter i PV-system6. PV-system i nätanslutna applikationer7. Globala aspekter på PV-solelektricitet8. PV-industrins resultatFoU om kristallina solceller dominerade stort, sedan tunnfilmsceller av främst amorft kisel. Intressant var att återvinning är föremål för FoU; dels återvinning av kiselsolceller när panelen tjänat ut; dels återvinning av Cu, Cd, Se och Te när tunnfilmscellerna tas ur bruk.237 företag fanns representerade i utställningen, varav 20 från Kina. Tyskland dominerade stort. Utställningen teman var följande: 1) Tillverkare av kiselplattor, solceller, PV-moduler, koncentratorer, solföljare (se bild nedan) 2) Tillverkare och återförsäljare av utrustning och material 3) Integrering och distribution av system 4) Mätningar och kontrollteknologi 5) Forskning och laboratorier 6) Service, teknik, konsulting 7) Myndigheter och föreningar 8) Media och förlag 9) Tillverkare av inverterare 10) Övrigt.
Resumo:
In Sweden, there are about 0.5 million single-family houses that are heated by electricity alone, and rising electricity costs force the conversion to other heating sources such as heat pumps and wood pellet heating systems. Pellet heating systems for single-family houses are currently a strongly growing market. Future lack of wood fuels is possible even in Sweden, and combining wood pellet heating with solar heating will help to save the bio-fuel resources. The objectives of this thesis are to investigate how the electrically heated single-family houses can be converted to pellet and solar heating systems, and how the annual efficiency and solar gains can be increased in such systems. The possible reduction of CO-emissions by combining pellet heating with solar heating has also been investigated. Systems with pellet stoves (both with and without a water jacket), pellet boilers and solar heating have been simulated. Different system concepts have been compared in order to investigate the most promising solutions. Modifications in system design and control strategies have been carried out in order to increase the system efficiency and the solar gains. Possibilities for increasing the solar gains have been limited to investigation of DHW-units for hot water production and the use of hot water for heating of dishwashers and washing machines via a heat exchanger instead of electricity (heat-fed appliances). Computer models of pellet stoves, boilers, DHW-units and heat-fed appliances have been developed and the parameters for the models have been identified from measurements on real components. The conformity between the models and the measurements has been checked. The systems with wood pellet stoves have been simulated in three different multi-zone buildings, simulated in detail with heat distribution through door openings between the zones. For the other simulations, either a single-zone house model or a load file has been used. Simulations were carried out for Stockholm, Sweden, but for the simulations with heat-fed machines also for Miami, USA. The foremost result of this thesis is the increased understanding of the dynamic operation of combined pellet and solar heating systems for single-family houses. The results show that electricity savings and annual system efficiency is strongly affected by the system design and the control strategy. Large reductions in pellet consumption are possible by combining pellet boilers with solar heating (a reduction larger than the solar gains if the system is properly designed). In addition, large reductions in carbon monoxide emissions are possible. To achieve these reductions it is required that the hot water production and the connection of the radiator circuit is moved to a well insulated, solar heated buffer store so that the boiler can be turned off during the periods when the solar collectors cover the heating demand. The amount of electricity replaced using systems with pellet stoves is very dependant on the house plan, the system design, if internal doors are open or closed and the comfort requirements. Proper system design and control strategies are crucial to obtain high electricity savings and high comfort with pellet stove systems. The investigated technologies for increasing the solar gains (DHW-units and heat-fed appliances) significantly increase the solar gains, but for the heat-fed appliances the market introduction is difficult due to the limited financial savings and the need for a new heat distribution system. The applications closest to market introduction could be for communal laundries and for use in sunny climates where the dominating part of the heat can be covered by solar heating. The DHW-unit is economical but competes with the internal finned-tube heat exchanger which is the totally dominating technology for hot water preparation in solar combisystems for single-family houses.
Resumo:
A solar thermal system with seasonal borehole storage for heating of a residential area in Anneberg, Sweden, approximately 10 km north of Stockholm, has been in operation since late 2002. Originally, the project was part of the EU THERMIE project “Large-scale Solar Heating Systems for Housing Developments” (REB/0061/97) and was the first solar heating plant in Europe with borehole storage in rock not utilizing a heat pump. Earlier evaluations of the system show lower performance than the preliminary simulation study, with residents complaining of a high use of electricity for domestic hot water (DHW) preparation and auxiliary heating. One explanation mentioned in the earlier evaluations is that the borehole storage had not yet reached “steady state” temperatures at the time of evaluation. Many years have passed since then and this paper presents results from a new evaluation. The main aim of this work is to evaluate the current performance of the system based on several key figures, as well as on system function based on available measurement data. The analysis show that though the borehole storage now has reached a quasi-steady state and operates as intended, the auxiliary electricity consumption is much higher than the original design values largely due to high losses in the distribution network, higher heat loads as well as lower solar gains.