3 resultados para THERMAL RATE COEFFICIENT
em Dalarna University College Electronic Archive
Resumo:
The aim of this master thesis is an investigation of the thermal performance of a thermal compound parabolic concentrating (CPC) collector from Solarus. The collector consists of two troughs with absorbers which are coated with different types of paint with unknown properties. The lower and upper trough of the collector have been tested individually. In order to accomplish the performance of the two collectors, a thorough literature study in the fields of CPC technology, various test methods, test standards for solar thermal collectors as well as the latest articles relating on the subject were carried out. In addition, the set‐up of the thermal test rig was part of the thesis as well. The thermal performance was tested according to the steady state test method as described in the European standard 12975‐2. Furthermore, the thermal performance of a conventional flat plate collector was carried out for verification of the test method. The CPC‐Thermal collector from Solarus was tested in 2013 and the results showed four times higher values of the heat loss coefficient UL (8.4 W/m²K) than what has been reported for a commercial collector from Solarus. This value was assumed to be too large and it was assumed that the large value was a result of the test method used that time. Therefore, another aim was the comparison of the results achieved in this work with the results from the tests performed in 2013. The results of the thermal performance showed that the optical efficiency of the lower trough of the CPC‐T collector is 77±5% and the corresponding heat loss coefficient UL 4.84±0.20 W/m²K. The upper trough achieved an optical efficiency of 75±6 % and a heat loss coefficient UL of 6.45±0.27 W/m²K. The results of the heat loss coefficients are valid for temperature intervals between 20°C and 80°C. The different absorber paintings have a significant impact on the results, the lower trough performs overall better. The results achieved in this thesis show lower heat loss coefficients UL and higher optical efficiencies compared to the results from 2013.
Resumo:
Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, the electrical performance evaluation of a low concentrating PVT collector was done through two testing parts: power comparison and performance ratio testing. For the performance ratio testing, it is required to identify and measure the factors affecting the performance ratio on a low concentrating PVT collector. Factors such as PV cell configuration, collector acceptance angle, flow rate, tracking the sun, temperature dependence and diffuse to irradiance ratio. Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden using the electrical equipment at the solar laboratory. The PV testing has showed differences between the two receivers. Back2 was producing 1.8 energy output more than Back1 throughout the day. Front1 and Front2 were almost the same output performance. Performance tests showed that the cell configuration for Receiver2 with cells grouping (6- 32-32-6) has proved to have a better performance ratio when to it comes to minimizing the shading effect leading to more output power throughout the day because of lowering the mismatch losses. Different factors were measured and presented in this thesis in chapter 5. With the current design, it has been obtained a peak power at STC of 107W per receiver. The solar cells have an electrical efficiency of approximately 19% while the maximum measured electrical efficiency for the collector was approximately 18 % per active cell area, in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was done to help Solarus AB to know how much the electrical performance is affected during variable ambient condition and be able to use the results for analyzing and introducing new modification if needed.
Resumo:
BACKGROUND: The role of inflammation and oxidative stress in mild renal impairment in the elderly is not well studied. Accordingly, we aimed at investigating the associations between estimated glomerular filtration rate (eGFR), albumin/creatinine ratio (ACR), and markers of different inflammatory pathways and oxidative stress in a community based cohort of elderly men. FINDINGS: Cystatin C-based GFR, ACR, and biomarkers of cytokine-mediated inflammation (interleukin-6, high-sensitivity C-reactive protein[CRP], serum amyloid A[SAA]), cyclooxygenase-mediated inflammation (urinary prostaglandin F2alpha [PGF2alpha]), and oxidative stress (urinary F2 isoprostanes) were assessed in the Uppsala Longitudinal Study of Adult Men(n = 647, mean age 77 years). RESULTS: In linear regression models adjusting for age, BMI, smoking, blood pressure, LDL-cholesterol, HDL-cholesterol, triglycerides, and treatment with statins, ACE-inhibitors, ASA, and anti-inflammatory agents, eGFR was inversely associated with CRP, interleukin-6, and SAA (beta-coefficient -0.13 to -0.19, p < 0.001 for all), and positively associated with urinary F2-isoprostanes (beta-coefficient 0.09, p = 0.02). In line with this, ACR was positively associated with CRP, interleukin-6, and SAA (beta- coefficient 0.09-0.12, p < 0.02 for all), and negatively associated with urinary F2-isoprostanes (beta-coefficient -0.12, p = 0.002). The associations were similar but with lower regression coefficients in a sub-sample with normal eGFR (>60 ml/min/1.73 m2, n = 514), with the exception that F2-isoprostane and SAA were no longer associated with eGFR. CONCLUSION: Our data indicate that cytokine-mediated inflammation is involved in the early stages of impaired kidney function in the elderly, but that cyclooxygenase-mediated inflammation does not play a role at this stage. The unexpected association between higher eGFR/lower albuminuria and increased F2-isoprostanes in urine merits further studies.