2 resultados para Saving and investment.

em Dalarna University College Electronic Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Börsnoterade bolag ska i sin koncernredovisning redovisa enligt IFRS och förvaltningsfastigheter skall redovisas enligt IAS 40 Förvaltningsfastigheter. Detta examensarbete undersöker hur Nordiska börsnoterade bolag tillämpar vissa punkter inom IAS 40 i 2014 års redovisning jämfört med 2009 års redovisning. Syftet med undersökningen är att undersöka skillnader mellan de granskade företagens redovisning 2014 och 2009, med utgångspunkten i en tidigare publicerad undersökning (Hedlund & Ersson, 2011). Det som undersöks är om företagen använder samma värderingsmetod, om de informerar om hur värdering av förvaltningsfastigheter skett, om var i resultatrapporten de rapporterar justeringar av verkligt värde samt hur väl de lämnar upplysningar enligt IAS 40 punkt 75. Undersökningen har skett med en kvantitativ metod då det är årsredovisningar som granskats. Undersökt data är årsredovisningar från 2014 och 2009 för samma företag som granskats i den tidigare undersökningen. Några företag har utgått då de inte ingår i urvalsramen Nordiskt börsnoterat fastighetsbolag. Totalt granskades 14 stycken företag. Resultatet visar att efterlevnaden totalt sett är något bättre 2014 jämfört med den tidigare undersökningen. Till stor del beror det på urvalet där de företag som utgått var dåliga på att lämna upplysningar enligt IAS 40 i 2009 års redovisning. Sett till de företag som är med i båda undersökningarna är efterlevnaden likartad de jämförda åren. Det är få företag som lämnar upplysningar om begränsningar i rätten att sälja förvaltningsfastigheter, avtalsenliga förpliktelser att köpa eller hur de skiljer på rörelsefastigheter och förvaltningsfastigheter. Tolkningen kan då göras att det inte finns någon restriktion eller förpliktelse om det inte lämnas några sådana upplysningar. Om det är ett fastighetsbolag så kan det tolkas som att de inte har några rörelsefastigheter. Med dessa tolkningar blir efterlevnaden bland de undersökta företagen god.