3 resultados para Proportional
em Dalarna University College Electronic Archive
Resumo:
The Sagnac effect is an important phase coherent effect in optical and atom interferometers where rotations of the interferometer with respect to an inertial reference frame result in a shift in the interference pattern proportional to the rotation rate. Here, we analyze the Sagnac effect in a mesoscopic semiconductor electron interferometer. We include in our analysis the Rashba spin-orbit interactions in the ring. Our results indicate that spin-orbit interactions increase the rotation-induced phase shift. We discuss the potential experimental observability of the Sagnac phase shift in such mesoscopic systems.
Resumo:
Objective: Turnover of the extracellular matrix in all solid organs is governed mainly by a balance between the degrading matrix metalloproteinases (MMPs) and their tissue inhibitors (TIMPs). An altered extracellular matrix metabolism has been implicated in a variety of diseases. We investigated relations of serum levels of MMP-9 and TIMP-1 to mortality risk from an etiological perspective. Design: The prospective Uppsala Longitudinal Study of Adult Men (ULSAM) cohort, followed from 1991–1995 for up to 18.1 years. A random population-based sample of 1,082 71-year-old men, no loss to follow-up. Endpoints were all-cause (n = 628), cardiovascular (n = 230), non-cardiovascular (n = 398) and cancer mortality (n = 178), and fatal or non-fatal myocardial infarction (n = 138) or stroke (n = 163). Results: Serum MMP-9 and TIMP-1 levels were associated with risk of all-cause mortality (Cox proportional hazard ratio [HR] per standard deviation 1.10, 95% confidence interval [CI] 1.03–1.19; and 1.11, 1.02–1.20; respectively). TIMP-1 levels were mainly related to risks of cardiovascular mortality and stroke (HR per standard deviation 1.22, 95% CI 1.09–1.37; and 1.18, 1.04–1.35; respectively). All relations except those of TIMP-1 to stroke risk were attenuated by adjustment for cardiovascular disease risk factors. Relations in a subsample without cardiovascular disease or cancer were similar to those in the total sample. Conclusion: In this community-based cohort of elderly men, serum MMP-9 and TIMP-1 levels were related to mortality risk. An altered extracellular matrix metabolism may be involved in several detrimental pathways, and circulating MMP-9 or TIMP-1 levels may be relevant markers thereof.
Demonstration of Solar Heating and Cooling System using Sorption Integrated Solar Thermal Collectors
Resumo:
Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic salt sorbent and water as a refrigerant, sealed under vacuum with no moving parts. A 5.6m2 aperture area outdoor laboratory-scale system of sorption module integrated solar collectors was installed in Stockholm, Sweden and evaluated under constant re-cooling and chilled fluid return temperatures in order to assess collector performance. Measured average solar cooling COP was 0.19 with average cooling powers between 120 and 200 Wm-2 collector aperture area. It was observed that average collector cooling power is constant at daily insolation levels above 3.6 kWhm-2 with the cooling energy produced being proportional to solar insolation. For full evaluation of an integrated sorption collector solar heating and cooling system, under the umbrella of a European Union project for technological innovation, a 180 m2 large-scale demonstration system has been installed in Karlstad, Sweden. Results from the installation commissioned in summer 2014 with non-optimised control strategies showed average electrical COP of 10.6 and average cooling powers between 140 and 250 Wm-2 collector aperture area. Optimisation of control strategies, heat transfer fluid flows through the collectors and electrical COP will be carried out in autumn 2014.