4 resultados para Passive immunization

em Dalarna University College Electronic Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prosodic /template Morphology, that "draws heavily on the theoretical apparatus and formalisms of the generative phonology model known as autosegmental phonology" (Katamba, F. 1993: 154), is the best analysis that can handle Arabic morphology. Verbs in Arabic are represented on three independent tiers: root tier, the skeletal tier and the vocalic melody tier (Katamba, F. 1993). Vowel morphemes, which are represented by diacritics, are inserted within the consonant morphemes, which are represented by primary symbols, to form words. The morpheme tier hypothesis paves the way to understand the nonconcatenative Arabic morphology. This paper analyzes gender in perfect active and passive 3rd person singular verbs on the basis of PM. The focus of the analysis shall be drawn heavily on the most common Arabic verbs; triconsonantal verbs, with brief introduction of the less common verbs; quadriconsonantal perfect active and passive masculine and feminine 3rd person singular verbs. I shall, too, cast the light on some vowel changes that some verbs undergo when voice changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research was carried out by studying possible renovation of a two-storey detached multifamily building by using passive solar design options in a cold climate in Borlänge, Sweden where the heating Degree Days are 4451 (base 20°C). Borlänge`s housing company, Tunabyggen, plans to renovate the project house located inthe multicultural district, Jakobsgårdarna. The goal of the thesis was to suggest a redesign of the current building, decrease the heating energy use, by applying passive solar design and control strategies, in a most reasonable way. In addition ensure a better thermal comfort for the tenants in the dwellings. Literatures have been studied, from which can be inferred that passive design should be abasic design consideration for all housing constructions, because it has advantages to ensure thermal comfort, and reduce the energy use. In addition further savings can be achieved applying different types of control strategies, from which the house will be more personalized, and better adapted to the user’s needs.The proposed method is based on simulations by using TRNSYS software. First a proper building model was set up, which represents the current state of the project building. Then the thermal insulation and the windows were upgraded, based on today's building regulations. The developments of the passive solar options were accomplished in two steps. First of all the relevant basic passive design elements were considered, then those advantages were compared to the advantages of applying new conventional thermostat, and shading control strategies.The results show that there is significant potential with the different types of passive solar design; their usage depends primarily on the location of the site as well as the orientation of the project building. Applying the control strategies, such as thermostat, and shading control, along the thermal insulation upgrade, may lead to significant energy savings (around 40 %), by comparison to the reference building without any upgrade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this project, Stora Enso’s newly developed building system has been further developed to allow building to the Swedish passive house standard for the Swedish climate. The building system is based on a building framework of CLT (Cross laminated timber) boards. The concept has been tested on a small test building. The experience gained from this test building has also been used for planning a larger building (two storeys with the option of a third storey) with passive house standard with this building system. The main conclusions from the project are:  It is possible to build airtight buildings with this technique without using traditional vapour barriers. Initial measurements show that this can be done without reaching critical humidity levels in the walls and roof, at least where wood fibre insulation is used, as this has a greater capacity for storing and evening out the moisture than mineral wool. However, the test building has so far not been exposed to internal generation of moisture (added moisture from showers, food preparation etc.). This needs to be investigated and this will be done during the winter 2013-14.  A new fixing method for doors and windows has been tested without traditional fibre filling between them and the CLT panel. The door or window is pressed directly on to the CLT panel instead, with an expandable sealing strip between them. This has been proved to be successful.  The air tightness between the CLT panels is achieved with expandable sealing strips between the panels. The position of the sealing strips is important, both for the air tightness itself and to allow rational assembly.  Recurrent air tightness measurements show that the air tightness decreased somewhat during the first six months, but not to such an extent that the passive house criteria were not fulfilled. The reason for the decreased air tightness is not clear, but can be due to small movements in the CLT construction and also to the sealing strips being affected by changing outdoor temperatures.  Long term measurements (at least two years) have to be carried out before more reliable conclusions can be drawn regarding the long term effect of the construction on air tightness and humidity in the walls.  An economic analysis comparing using a concrete frame or the studied CLT frame for a three storey building shows that it is probably more expensive to build with CLT. For buildings higher than three floors, the CLT frame has economic advantages, mainly because of the shorter building time compared to using concrete for the frame. In this analysis, no considerations have been taken to differences in the influence on the environment or the global climate between the two construction methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Det mobila operativsystemet Android är idag ett ganska dominerande operativsystem på den mobila marknaden dels på grund av sin öppenhet men också på grund av att tillgängligheten är stor i och med både billiga och dyra telefoner finns att tillgå. Men idag har Android inget fördefinierat designmönster vilket leder till att varje utvecklare får bestämma själv vad som ska användas, vilket ibland kan leda till onödigt komplex kod i applikationerna som sen blir svårtestad och svårhanterlig. Detta arbete ämnar jämföra två designmönster, Passive Model View Controller (PMVC) och Model View View-Model (MVVM), för att se vilket designmönster som blir minst komplext med hjälp av att räkna fram mätvärden med hjälp av Cyclomatic Complexity Number (CCN). Studien är gjord utifrån arbetssättet Design & Creation och ämnar bidra med: kunskap om vilket mönster man bör välja, samt om CCN kan peka ut vilka delar i en applikation som kommer att ta mer eller mindre lång tid att testa. Under studiens gång tog vi även fram skillnader på om man anväder sig av den så kallade Single Responsibilyt Principle (SRP) eller inte. Detta för att se om separerade vyer gör någon skillnad i applikationernas komplexitet. I slutändan så visar studien på att komplexiteten i små applikationer är väldigt likvärdig, men att man även på små applikationer kan se skillnad på hur komplex koden är men också att kodkomplexitet på metodnivå kan ge riktlinjer för testfall.