3 resultados para Partial meet contraction
em Dalarna University College Electronic Archive
Resumo:
Foreign graduates have been part of the success stories of many developed countries. This is as a result of their immeasurable deposit of ideas, knowledge, and innovation in the host country. Though the process of these foreign graduates penetrating and integrating into the labour market of the host country could be slow and rough as they encounter some obstacles on the way; they still strive to break through and be part of the country’s workforce because they foresee some opportunities therein. This research study is about the obstacles and opportunities foreign graduates meet in Dalarna labour market. The study investigated and identified the obstacles and opportunities foreign graduates meet in Dalarna labour market. For a thorough execution of this research, we collected primary data by handing questionnaires to 65 foreign graduates searching for jobs in Dalarna region and interviewed eight people, among which seven were foreign graduates and one of them was a staff at Arbestförmedlingen (Employment Agency) to give us a general view of the Dalarna labour market. We read previous research works and related articles to understand the topic in order to get an overview of the terminologies and concept to apply. This study concluded that language is a major obstacle foreign graduates meet in the Dalarna labour market. Other possible obstacles include culture, poor integration policies, lack of a placement bureau, lack of trust, limited opportunities, favoritism, lack of jobs, lack of references and experience. On the other hand factors like job availability, outgoing labour force and unskilled labour are possible opportunities foreign graduates meet in the Dalarna labour market. Furthermore flexible work time, good working atmosphere, experience, social security/welfare, good standard of living, family friendly region, higher wages, job security and cheap cost of living are also possible benefits that foreign graduates get in Dalarna.
Resumo:
The paper analyses empirical performance data of five commercial PV-plants in Germany. The purpose was on one side to investigate the weak light performance of the different PV-modules used. On the other hand it was to quantify and compare the shading losses of different PV-array configurations. The importance of this study relies on the fact that even if the behavior under weak light conditions or the shading losses might seem to be a relatively small percentage of the total yearly output; in projects where a performance guarantee is given, these variation can make the difference between meeting or not the conditions.When analyzing the data, a high dispersion was found. To reduce the optical losses and spectral effects, a series of data filters were applied based on the angle of incidence and absolute Air Mass. To compensate for the temperature effects and translate the values to STC (25°C), five different methods were assessed. At the end, the Procedure 2 of IEC 60891 was selected due to its relative simplicity, usage of mostly standard parameters found in datasheets, good accuracy even with missing values, and its potential to improve the results when the complete set of inputs is available.After analyzing the data, the weak light performance of the modules did not show a clear superiority of a certain technology or technology group over the others. Moreover, the uncertainties in the measurements restrictive the conclusiveness of the results.In the partial shading analysis, the landscape mounting of mc-Si PV-modules in free-field showed a significantly better performance than the portrait one. The cross-table string using CIGS modules did not proved the benefits expected and performed actually poorer than a regular one-string-per-table layout. Parallel substrings with CdTe showed a proper functioning and relatively low losses. Among the two product generations of CdTe analyzed, none showed a significantly better performance under partial shadings.
Resumo:
A common problem when planning large free field PV-plants is optimizing the ground occupation ratio while maintaining low shading losses. Due to the complexity of this task, several PV-plants have been built using various configurations. In order to compare the shading losses of different PV technologies and array designs, empirical performance data of five free field PV-plants operating in Germany was analyzed. The data collected comprised 140 winter days from October 2011 until March 2012. The relative shading losses were estimated by comparing the energy output of selected arrays in the front rows (shading-free) against that of shaded arrays in the back rows of the same plant. The results showed that landscape mounting with mc-Si PV-modules yielded significantly better results than portrait one. With CIGS modules, making cross-table strings using the lower modules was not beneficial as expected and had more losses than a one-string-per-table layout. Parallel substrings with CdTe showed relatively low losses. Among the two CdTe products analyzed, none showed a significantly better performance.