2 resultados para POTENTIAL COST-EFFECTIVENESS
em Dalarna University College Electronic Archive
Resumo:
Background: Although breast milk has numerous benefits for infants' development, with greater effects in those born preterm (at < 37 gestational weeks), mothers of preterm infants have shorter breastfeeding duration than mothers of term infants. One of the explanations proposed is the difficulties in the transition from a Neonatal Intensive Care Unit (NICU) to the home environment. A person-centred proactive telephone support intervention after discharge from NICU is expected to promote mothers' sense of trust in their own capacity and thereby facilitate breastfeeding. Methods/design: A multicentre randomized controlled trial has been designed to evaluate the effectiveness and cost-effectiveness of person-centred proactive telephone support on breastfeeding outcomes for mothers of preterm infants. Participating mothers will be randomized to either an intervention group or control group. In the intervention group person-centred proactive telephone support will be provided, in which the support team phones the mother daily for up to 14 days after hospital discharge. In the control group, mothers are offered a person-centred reactive support where mothers can phone the breastfeeding support team up to day 14 after hospital discharge. The intervention group will also be offered the same reactive telephone support as the control group. A stratified block randomization will be used; group allocation will be by high or low socioeconomic status and by NICU. Recruitment will be performed continuously until 1116 mothers (I: 558 C: 558) have been included. Primary outcome: proportion of mothers exclusively breastfeeding at eight weeks after discharge. Secondary outcomes: proportion of breastfeeding (exclusive, partial, none and method of feeding), mothers satisfaction with breastfeeding, attachment, stress and quality of life in mothers/partners at eight weeks after hospital discharge and at six months postnatal age. Data will be collected by researchers blind to group allocation for the primary outcome. A qualitative evaluation of experiences of receiving/providing the intervention will also be undertaken with mothers and staff. Discussion: This paper presents the rationale, study design and protocol for a RCT providing person-centred proactive telephone support to mothers of preterm infants. Furthermore, with a health economic evaluation, the cost-effectiveness of the intervention will be assessed. Trial registration: NCT01806480
Resumo:
Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.